41 research outputs found

    Methotrexate hepatotoxicity in patients with rheumatoid arthritis.

    Get PDF
    BACKGROUND Increases in aminotransferases (transaminitis) are potential major adverse reactions seen with long-term use of methotrexate (MTX). The aim of this study, therefore was to evaluate the incidence of MTX induced hepatotoxicity and its risk factors among rheumatoid arthritis (RA) patients. METHODS This retrospective study described 286 patients with RA who received ā‰„ 7.5 mg MTX weekly in an academic rheumatology clinic over a 15 year period. The results of serial liver function tests, concurrent MTX dose, cumulative dose and use of hepatotoxic drugs were collected and statistically analyzed according to a consecutive elevation in aminotransferases which occurred over at least a two week interval. RESULTS During the study period, 286 patients (84.4% female) with mean age of 46.6Ā±12.7 years (18-84 years) were enrolled. Transaminitis occurred among 23.7% of patients (incidence: 6.9 per 100 person-years) during 40.5Ā±34.6 month's exposure to MTX (989.6 person-years). The time difference between onset of therapy and occurrence of transaminitis was 22.1Ā±22.0 months. The only significant factor related to the occurrence of transaminitis was the duration of MTX therapy. The average duration of treatment among patients with transaminitis (59.6Ā±42.3 months) was greater than those with no transaminitis (p<0.001). The cumulative dose of MTX was significantly related to the occurrence of transaminitis (p<0.001). CONCLUSION MTX hepatotoxicity is a common complication of long-term treatment with MTX. It is associated with mild liver enzyme elevation and related to the duration of therapy

    Turbulence Closure Effect on the Free Surface Prediction Using Multi-Phase MPS Method

    Get PDF
    Source: ICHE Conference Archive - https://mdi-de.baw.de/icheArchiv

    Evaluation of the Safe Ischemic Time of Clamping During Intermittent Pringles Maneuver in Rabbits

    Get PDF
    Background: The liver is the most commonly injured organ in blunt abdominal trauma. Although major hepatic bleeding may be partially controlled with portal triade clamping (the Pringleā€™s maneuver), continuous prolonged clamping results in liver ischemia. Objectives: The purpose of this study was to determine the safe time of Pringle maneuver based on pathologic changes of liver in rabbit models. Materials and Methods: In an experimental study, 20 New-Zealand white rabbits were selected. In laparotomy, a blunt dissector was passed through the foramen of Winslow and the hepato-duodenal ligament encircled with an umbilical tape. En masse Pringle maneuver was performed using atraumatic flexible clamps. Rabbits were divided into four groups based on Pringle maneuver time (30 minutes, 45 minutes, 60 minutes, and 75 minutes). A hepatic biopsy was performed at the beginning of operation. The degree of tissue injury was evaluated using blood markers. Results: There were five rabbits in each group. At the end of 60 minutes ischemia, only minor alterations were observed in pathological specimens. At the end of 75 minutes, hepatocyte damage and necrosis were observed. The serum levels of alanine aminotransferase (Group A: P = 0.02; Group B: P = 0.01; Group C: P = 0.0002; Group D: P = 0.01) and Aspartate aminotransferase (Group A: P = 0.03; Group B: P = 0.002; Group C: P = 0.0004; Group D: P = 0.0003) were significantly increased post-operatively. The maximum level was in the first day after operation. Conclusions: Continuous portal triade clamping (the Pringle maneuver) during liver ischemia (30 and 45 minutes) in rabbits resulted in no ischemic change. Increasing time of clamping to 30 minutes was safe in intermittent Pringle maneuver

    Diagnostic Accuracy of Age and Alarm Symptoms for Upper GI Malignancy in Patients with Dyspepsia in a GI Clinic: A 7-Year Cross-Sectional Study

    Get PDF
    <div><h3>Objectives</h3><p>We investigated whether using demographic characteristics and alarm symptoms can accurately predict cancer in patients with dyspepsia in Iran, where upper GI cancers and <em>H. pylori</em> infection are common.</p> <h3>Methods</h3><p>All consecutive patients referred to a tertiary gastroenterology clinic in Tehran, Iran, from 2002 to 2009 were invited to participate in this study. Each patient completed a standard questionnaire and underwent upper gastrointestinal endoscopy. Alarm symptoms included in the questionnaire were weight loss, dysphagia, GI bleeding, and persistent vomiting. We used logistic regression models to estimate the diagnostic value of each variable in combination with other ones, and to develop a risk-prediction model.</p> <h3>Results</h3><p>A total of 2,847 patients with dyspepsia participated in this study, of whom 87 (3.1%) had upper GI malignancy. Patients reporting at least one of the alarm symptoms constituted 66.7% of cancer patients compared to 38.9% in patients without cancer (p<0.001). Esophageal or gastric cancers in patients with dyspepsia was associated with older age, being male, and symptoms of weight loss and vomiting. Each single predictor had low sensitivity and specificity. Using a combination of age, alarm symptoms, and smoking, we built a risk-prediction model that distinguished between high-risk and low-risk individuals with an area under the ROC curve of 0.85 and acceptable calibration.</p> <h3>Conclusions</h3><p>None of the predictors demonstrated high diagnostic accuracy. While our risk-prediction model had reasonable accuracy, some cancer cases would have remained undiagnosed. Therefore, where available, low cost endoscopy may be preferable for dyspeptic older patient or those with history of weight loss.</p> </div

    Design process and simulation testing of a shape memory alloy actuated robotic microgripper

    Get PDF
    Microgrippers are commonly used for micromanipulation of micro-objects with dimensions from 1 to 100 Āµm and attain features of reliable accuracy, low cost, wide jaw aperture and variable applied force. This paper studies the design process, simulation, and testing of a microgripper which can manipulate and assemble a platinum resistance temperature probe, made from a 25 Āµm diameter platinum wire, a 20 mm diameter tinned copper wire, and a printed circuit board type connector. Various microgripper structures and actuator types were researched and reviewed to determine the most suitable design for the required micromanipulation task. Operation tests using SolidWorks and ANSYS software were conducted to test a parallelogram structure with flexible single-notch hinges. The best suited material was found to be Aluminium alloy 7075-T6 as it was capable of producing a large jaw tip displacement of 0.7 mm without exceeding its tensile yield strength limit. A shape memory alloy was chosen as a choice of actuator to close the microgripper jaws. To ensure a repeatably accurate datum point, the final microgripper consisted of a fixed arm and a flexible arm. An optimisation process using ANSYS studied the hinge thickness and radius dimensions of the microgripper which improved its deflection whilst reducing the experienced stress

    Prognostic value of endoscopic ultrasound in acute pancreatitis

    No full text
    Background/Aims: Endoscopic ultrasonography (EUS) is a useful modality to diagnose causes of pancreatitis. The role of EUS for prediction of pancreatitis severity has not been studied. The aim of this study was to identify the utility of EUS in determining the severity of acute pancreatitis (AP). Methods: All patients diagnosed with pancreatitis consecutively underwent EUS on the 2nd day of their admission. Atlanta criteria were used as the severity index of pancreatitis. Results: During the study period, 114 patients (74 females, 40 males; mean age of 53.03 Ā± 17.7 years) were enrolled in the study. The most common cause of AP was gallstone (78.9%). According to the Atlanta criteria, pancreatitis was mild in 72 (63.2%) and severe in 42 (36.8%) patients. In univariate analysis, the presence of peripancreatic edema, pancreas inhomogeneity, common bile duct dilation and ascites were associated with severe pancreatitis. In multivariate analysis, only the presence of peripancreatic edema in EUS correlated with the severity of AP according to the Atlanta criteria (sensitivity, specificity and accuracy: 65.8, 75.7 and 72.2%, respectively). Conclusion: EUS may be a new useful imaging modality for prediction of severity of AP and may have prognostic significance in the early phase of AP. Copyright Ā© 2011 S. Karger AG, Basel and IAP
    corecore