291 research outputs found
A comparison of tree segmentation methods using very high density airborne laser scanner data
Abstract. Developments of LiDAR technology are decreasing the unit cost per single point (e.g. single-photo counting). This brings to the possibility of future LiDAR datasets having very dense point clouds. In this work, we process a very dense point cloud (~200 points per square meter), using three different methods for segmenting single trees and extracting tree positions and other metrics of interest in forestry, such as tree height distribution and canopy area distribution. The three algorithms are tested at decreasing densities, up to a lowest density of ~5 point per square meter. Accuracy assessment is done using Kappa, recall, precision and F-Score metrics comparing results with tree positions from groundtruth measurements in six ground plots where tree positions and heights were surveyed manually. Results show that one method provides better Kappa and recall accuracy results for all cases, and that different point densities, in the range used in this study, do not affect accuracy significantly. Processing time is also considered; the method with better accuracy is several times slower than the other two methods and increases exponentially with point density. Best performer gave Kappa = 0.7. The implications of metrics for determining the accuracy of results of point positions’ detection is reported. Motives for the different performances of the three methods is discussed and further research direction is proposed.
</jats:p
Dethinning Extensive Air Shower Simulations
We describe a method for restoring information lost during statistical
thinning in extensive air shower simulations. By converting weighted particles
from thinned simulations to swarms of particles with similar characteristics,
we obtain a result that is essentially identical to the thinned shower, and
which is very similar to non-thinned simulations of showers. We call this
method dethinning. Using non-thinned showers on a large scale is impossible
because of unrealistic CPU time requirements, but with thinned showers that
have been dethinned, it is possible to carry out large-scale simulation studies
of the detector response for ultra-high energy cosmic ray surface arrays. The
dethinning method is described in detail and comparisons are presented with
parent thinned showers and with non-thinned showers
One-repetition-maximum measures or maximum bar-power output: which Is more related to sport performance?
Purpose: This study compared the associations between optimum power loads and 1-repetition maximum (1RM) values (assessed in half-squat [HS] and jump squat [JS] exercises) and multiple performance measures in elite athletes.
Methods: Sixty-one elite athletes (fifteen Olympians) from four different sports (track and field [sprinters and jumpers], rugby sevens, bobsled, and soccer) performed squat and countermovement jumps, HS exercise (for assessing 1RM), HS and JS exercises (for assessing bar-power output), and sprint tests (60-m for sprinters and jumpers and 40-m for the other athletes). Pearson’s product moment correlation test was used to determine relationships between 1RM and bar-power outputs with vertical jumps and sprint times in both exercises.
Results: Overall, both measurements were moderately to near perfectly related to speed performance (r values varying from -0.35 to -0.69 for correlations between 1RM and sprint times, and from -0.36 to -0.91 for correlations between bar-power outputs and sprint times; P< 0.05). However, on average, the magnitude of these correlations was stronger for power-related variables, and only the bar-power outputs were significantly related to vertical jump height.
Conclusions: The bar-power outputs were more strongly associated with sprint-speed and power performance than the 1RM measures. Therefore, coaches and researchers can use the bar-power approach for athlete testing and monitoring. Due to the strong correlations presented, it is possible to infer that meaningful variations in bar-power production may also represent substantial changes in actual sport performance
Personality Traits in Miners with Past Occupational Elemental Mercury Exposure
In this study, we evaluated the impact of long-term occupational exposure to elemental mercury vapor (Hg(0)) on the personality traits of ex-mercury miners. Study groups included 53 ex-miners previously exposed to Hg(0) and 53 age-matched controls. Miners and controls completed the self-reporting Eysenck Personality Questionnaire and the Emotional States Questionnaire. The relationship between the indices of past occupational exposure and the observed personality traits was evaluated using Pearson’s correlation coefficient and on a subgroup level by machine learning methods (regression trees). The ex-mercury miners were intermittently exposed to Hg(0) for a period of 7–31 years. The means of exposure-cycle urine mercury (U-Hg) concentrations ranged from 20 to 120 μg/L. The results obtained indicate that ex-miners tend to be more introverted and sincere, more depressive, more rigid in expressing their emotions and are likely to have more negative self-concepts than controls, but no correlations were found with the indices of past occupational exposure. Despite certain limitations, results obtained by the regression tree suggest that higher alcohol consumption per se and long-term intermittent, moderate exposure to Hg(0) (exposure cycle mean U-Hg concentrations > 38.7 < 53.5 μg/L) in interaction with alcohol remain a plausible explanation for the depression associated with negative self-concept found in subgroups of ex-mercury miners. This could be one of the reason for the higher risk of suicide among miners of the Idrija Mercury Mine in the last 45 years
Dependence of geosynchrotron radio emission on the energy and depth of maximum of cosmic ray showers
Based on CORSIKA and REAS2 simulations, we investigate the dependence of
geosynchrotron radio emission from extensive air showers on the energy of the
primary cosmic ray and the depth of the shower maximum. It is found that at a
characteristic lateral distance, the amplitude of the bandpass-filtered radio
signal is directly proportional to the energy deposited in the atmosphere by
the electromagnetic cascade, with an RMS uncertainty due to shower-to-shower
fluctuations of less than 3%. In addition, the ratio of this radio amplitude
and that at a larger lateral distance is directly related to the atmospheric
depth of the shower maximum, with an RMS uncertainty of ~15-20 g cm-2. By
measuring these quantities, geosynchrotron radio emission from cosmic ray air
showers can be used to infer the energy of the primary particle and the depth
of the air shower maximum on a shower-to-shower basis.Comment: version accepted by Astroparticle Physics; slightly changed title and
wording; one additional figur
Post‐activation potentiation: is there an optimal training volume and intensity to Induce improvements in vertical jump ability in highly‐trained subjects?
The aim of this study was to compare the acute effects of performing half squats (HSs) with different loading intensities (1, 3, and 5 repetitions maximum [RM], and 60% 1RM) and a different number of sets (1, 2, and 3) on the countermovement jump (CMJ) performance of 18 highly‐trained male subjects. Participants were submitted to four experimental conditions (1RM, 3RM, 5RM, and 60% 1RM) in randomized order. The CMJ was assessed before and after each set. Differences in CMJ performance between the distinct experimental conditions and individual responses in CMJ performance induced by the different protocols were analyzed via the magnitude‐based inference method. Overall, significant improvements were detected in individual CMJ heights after each activation protocol. It can be concluded that the use of 1 to 3 sets of HSs performed at moderate‐to‐high loads may be an effective strategy to improve jump performance in highly‐trained subjects. Nonetheless, despite the high efficiency of the protocols tested here, coaches and researchers are strongly encouraged to perform individualized assessments within the proposed range of loads and sets, to find optimal and tailored post‐activation potentiation protocols
Post-activation potentiation: is there an optimal training volume and intensity to induce improvements in vertical jump ability in highly-trained subjects?
The aim of this study was to compare the acute effects of performing half squats (HSs) with different loading intensities (1, 3, and 5 repetitions maximum [RM], and 60% 1RM) and a different number of sets (1, 2, and 3) on the countermovement jump (CMJ) performance of 18 highly-trained male subjects. Participants were submitted to four experimental conditions (1RM, 3RM, 5RM, and 60% 1RM) in randomized order. The CMJ was assessed before and after each set. Differences in CMJ performance between the distinct experimental conditions and individual responses in CMJ performance induced by the different protocols were analyzed via the magnitude-based inference method. Overall, significant improvements were detected in individual CMJ heights after each activation protocol. It can be concluded that the use of 1 to 3 sets of HSs performed at moderate-to-high loads may be an effective strategy to improve jump performance in highly-trained subjects. Nevertheless, despite the high efficiency of the protocols tested here, coaches and researchers are strongly encouraged to perform individualized assessments within the proposed range of loads and sets, to find optimal and tailored post-activation potentiation protocols
PHOTON BEAMLINE CONTROL SYSTEM AS A PRODUCT
Abstract Every beamline is different, which makes it impossible to buy a control system off the shelf. Nevertheless well tested and customizable building blocks can be prepared, which are then put together according to customer requirements. Delivering a fully operational control system is not just software development, but also gathering specifications, writing documentation, testing the hardware and trimming the software on site. Based on the delivery of a number of working beamline control systems, this paper will prove that we have optimized all stages and can guarantee that the purchased control system will be delivered on time, will work according to specifications and will be properly documented. The customers can also count on support
- …