4 research outputs found

    Flow-diverting stents allow efficient treatment of unruptured, intradural dissecting aneurysms of the vertebral artery: An explanatory approach using in vivo flow analysis

    No full text
    Object Our study aimed to evaluate the efficiency of flow-diverting stents (FDS) in treating unruptured, intradural dissecting aneurysms of the vertebral artery (VADAs). Additionally, the effect of FDS on the aneurysmal flow pattern was investigated by performing in vivo flow analysis using parametric color coding (PCC). Methods We evaluated 11 patients with unruptured, intradural VADAs, treated with FDS. Pre- and postinterventional DSA-series were postprocessed by PCC, and time-density curves were calculated. The parameters aneurysmal inflow-velocity, outflow-velocity and relative time-to-peak (rTTP) were calculated. Pre- and postinterventional values were compared and correlated with the occlusion rate after six months. Results Follow-up DSA detected 10 aneurysms occluded, meaning an occlusion rate of 91%. No procedure-related morbidity and mortality was found. Flow analyses revealed a significant reduction of aneurysmal inflow- velocity and prolongation of rTTP after FDS deployment. Concerning aneurysm occlusion, the postinterventional outflow-velocity turned out to be a marginally statistically significant predictor. A definite threshold value (–0.7 density change/s) could be determined for the outflow-velocity that allows prediction of complete aneurysm occlusion with high sensitivity and specificity (100%). Conclusions Using FDS can be considered an efficient and safe therapy option in treating unruptured, intradural VADA. From in vivo flow analyses the postinterventional aneurysmal outflow-velocity turned out to be a potential predictor for later complete aneurysm occlusion. Here, it might be possible to determine a threshold value that allows prediction of aneurysm occlusion with high specificity and sensitivity. As fast, applicable and easy-to-handle tool, PCC could be used for procedural monitoring and might contribute to further treatment optimization

    Optimized Flat-Detector CT in Stroke Imaging: Ready for First-Line Use?

    No full text
    Background: Using flat-detector CT (FD-CT) for stroke imaging has the advantage that both diagnostic imaging and endovascular therapy can be performed directly within the Angio Suite without any patient transfer and time delay. Thus, stroke management could be speeded up significantly, and patient outcome might be improved. But as precondition for using FD-CT as primary imaging modality, a reliable exclusion of intracranial hemorrhage (ICH) has to be possible. This study aimed to investigate whether optimized native FD-CT, using a newly implemented reconstruction algorithm, may reliably detect ICH in stroke patients. Additionally, the potential to identify ischemic changes was evaluated. Methods: Cranial FD-CT scans were obtained in 102 patients presenting with acute ischemic stroke (n = 32), ICH (n = 45) or transient ischemic attack (n = 25). All scans were reconstructed with a newly implemented half-scan cone-beam algorithm. Two experienced neuroradiologists, unaware of clinical findings, evaluated independently the FD-CTs screening for hemorrhage or ischemic signs. The findings were correlated to CT, and rater and inter-rater agreement was assessed. Results: FD-CT demonstrated high sensitivity (95-100%) and specificity (100%) in detecting intracerebral and intraventricular hemorrhage (IVH). Overall, interobserver agreement (κ = 0.92) was almost perfect and rater agreement to CT highly significant (r = 0.81). One infratentorial ICH and 10 or 11 of 22 subarachnoid hemorrhages (SAHs) were missed of whom 7 were perimesencephalic. The sensitivity for detecting acute ischemic signs was poor in blinded readings (0 or 25%, respectively). Conclusions: Optimized FD-CT, using a newly implemented reconstruction algorithm, turned out as a reliable tool for detecting supratentorial ICH and IVH. However, detection of infratentorial ICH and perimesencephalic SAH is limited. The potential of FD-CT in detecting ischemic changes is poor in blinded readings. Thus, plain FD-CT seems insufficient as a standalone modality in acute stroke, but within a multimodal imaging approach primarily using the FD technology, native FD-CT seems capable to exclude reliably supratentorial hemorrhage. Currently, FD-CT imaging seems not yet ready for wide adoption, replacing regular CT, and should be reserved for selected patients. Furthermore, prospective evaluations are necessary to validate this approach in the clinical setting

    Sustained increase of somatosensory cortex excitability by tactile coactivation studied by paired median nerve stimulation in humans correlates with perceptual gain

    No full text
    Cortical excitability can be reliably assessed by means of paired-pulse stimulation techniques. Recent studies demonstrated particularly for motor and visual cortex that cortical excitability is systematically altered following the induction of learning processes or during the development of pathological symptoms. A recent tactile coactivation protocol developed by Godde and coworkers showed that improvement of tactile performance in humans can be achieved also without training through passive stimulation on a time scale of a few hours. Tactile coactivation evokes plastic changes in somatosensory cortical areas as measured by blood oxygenation level-dependent (BOLD) activation in fMRI or SEP-dipole localization, which correlated with the individual gain in performance. To demonstrate changes in excitability of somatosensory cortex after tactile coactivation, we combined assessment of tactile performance with recordings of paired-pulse SEPs after electrical median nerve stimulation of both the right coactivated and left control hand at ISIs of 30 and 100 ms before, 3 h after and 24 h after tactile coactivation. Amplitudes and latencies of the first and second cortical N20/P25 response components were calculated. For the coactivated hand, we found significantly lowered discrimination thresholds and significantly reduced paired-pulse ratios (second N20/P25 response/first N20/P25 response) at an ISI of 30 ms after tactile coactivation indicating enhanced cortical excitability. No changes in paired-pulse behaviour were observed for ISIs of 100 ms. Both psychophysical and cortical effects recovered to baseline 24 h after tactile coactivation. The individual increase of excitability correlated with the individual gain in discrimination performance. For the left control hand we found no effects of tactile coactivation on paired-pulse behaviour and discrimination threshold. Our results indicate that changes in cortical excitability are modified by tactile coactivation and were scaled with the degree of improvement of the individual perceptual learning. Conceivably, changes of cortical excitability seem to constitute an additional important marker and mechanism underlying plastic reorganization
    corecore