    Tracheal tube-tip displacement in children during head-neck movement—a radiological assessment

    Get PDF
    Background. Aims of this study were to assess the maximum displacement of tracheal tube tip during head-neck movement in children, and to evaluate the appropriateness of the intubation depth marks on the Microcuff Paediatric Endotracheal Tube regarding the risk of inadvertent extubation and endobronchial intubation. Methods. We studied children, aged from birth to adolescence, undergoing cardiac catheterization. The patients' tracheas were orally intubated and the tracheal tubes positioned with the intubation depth mark at the level of the vocal cords. The tracheal tube tip-to-carina distances were fluoroscopically assessed with the patient supine and the head-neck in 30° flexion, 0° neutral position and 30° extension. Results. One hundred children aged between 0.02 and 16.4 yr (median 5.1 yr) were studied. Maximum tracheal tube-tip displacement after head-neck 30° extension and 30° flexion demonstrated a linear relationship to age [maximal upward tube movement (mm)=0 0.71×age (yr)+9.9 (R2=0.893); maximal downward tube movement (mm)=0.83×age (yr)+9.3 (R2=0.949)]. Maximal tracheal tube-tip downward displacement because of head-neck flexion was more pronounced than upward displacement because of head-neck extension. Conclusions. The intubation depth marks were appropriate to avoid inadvertent tracheal extubation and endobronchial intubation during head-neck movement in all patients. However, during head-neck extension the tracheal tube cuff may become positioned in the subglottic region and should be re-adjusted when the patient remains in this position for a longer tim

    Perioperative Course and Socioeconomic Status Predict Long-Term Neurodevelopment Better Than Perioperative Conventional Neuroimaging in Children with Congenital Heart Disease.

    Get PDF
    The objective of the study was to compare the use of neonatal conventional brain magnetic resonance imaging (MRI) with that of clinical factors and socioeconomic status (SES) to predict long-term neurodevelopment in children with severe congenital heart disease (CHD). In this prospective cohort study, perioperative MRIs were acquired in 57 term-born infants with CHD undergoing cardiopulmonary bypass surgery during their first year of life. Total brain volume (TBV) was measured using an automated method. Brain injury severity (BIS) was assessed by an established scoring system. The neurodevelopmental outcome was assessed at 6 years using standardized test batteries. A multiple linear regression model was used for cognitive and motor outcomes with postoperative TBV, perioperative BIS, CHD complexity, length of hospital stay, and SES as covariates. CHD diagnoses included univentricular heart defect (n = 15), transposition of the great arteries (n = 33), and acyanotic CHD (n = 9). Perioperative moderate-to-severe brain injury was detected in 15 (26%) patients. The total IQ was similar to test norms (P = .11), whereas the total motor score (P < .001) was lower. Neither postoperative TBV nor perioperative BIS predicted the total IQ, but SES (P < .001) and longer hospital stay (P = .004) did. No factor predicted the motor outcome. Although the predictive value of neonatal conventional MRIs for long-term neurodevelopment is low, duration of hospital stay and SES better predict the outcome in this CHD sample. These findings should be considered in initiating early therapeutic support

    Cardiac output measurement in children: comparison of Aesculon® cardiac output monitor and thermodilution

    Get PDF
    Background We compared cardiac output (CO) measurements by the non-invasive electrical velocimetry (Aesculon®) monitor with the pulmonary artery catheter (PAC) thermodilution method in children. Methods CO values using the Aesculon® monitor and PAC thermodilution were simultaneously recorded during cardiac catheterization in children. Measurements were performed under general anaesthesia. To compare, three consecutive measurements for each patient within 3 min were obtained. The means of the three values were compared using simple regression and Bland-Altman analysis. Data were presented as mean (sd). A mean percentage of <30% was defined to indicate clinical useful reliability of the Aesculon® monitor. Results A total of 50 patients with a median (range) age of 7.5 (0.5-16.5) yr were enrolled in the study. Mean CO values were 3.7 (1.5) litre min−1 (PAC thermodilution) and 3.1 (1.7) litre min−1 (Aesculon® monitor). Analysis for CO measurement showed a good correlation between the two methods (r=0.894; P<0.0001). The bias between the two methods was 0.66 litre min−1 with a precision of 1.49 litre min−1. The mean percentage error for CO measurements was 48.9% for the Aesculon® monitor when compared with PAC thermodilution. Conclusions Electrical velocimetry using the Aesculon® monitor did not provide reliable CO values when compared with PAC thermodilution. Whether the Aesculon® monitor can be used as a CO trend monitor has to be assessed by further investigations in patients with changing haemodynamic

    The development of a new blood substitute

    Get PDF
    Trattasi di un sommario pubblicato online nel sito dell'Agenzia di divulgazione scientifica Atlas of Science, AoS Nordic AB, Moscow, Russia, riguardante l'impiego di nuovi sostituti del sangu

    A Uniform Description of Perioperative Brain MRI Findings in Infants with Severe Congenital Heart Disease:Results of a European Collaboration

    Get PDF
    BACKGROUND AND PURPOSE: A uniform description of brain MR imaging findings in infants with severe congenital heart disease to assess risk factors, predict outcome, and compare centers is lacking. Our objective was to uniformly describe the spectrum of perioperative brain MR imaging findings in infants with congenital heart disease. MATERIALS AND METHODS: Prospective observational studies were performed at 3 European centers between 2009 and 2019. Brain MR imaging was performed preoperatively and/or postoperatively in infants with transposition of the great arteries, single-ventricle physiology, or left ventricular outflow tract obstruction undergoing cardiac surgery within the first 6 weeks of life. Brain injury was assessed on T1, T2, DWI, SWI, and MRV. A subsample of images was assessed jointly to reach a consensus. RESULTS: A total of 348 MR imaging scans (180 preoperatively, 168 postoperatively, 146 pre- and postoperatively) were obtained in 202 infants. Preoperative, new postoperative, and cumulative postoperative white matter injury was identified in 25%, 30%, and 36%; arterial ischemic stroke, in 6%, 10%, and 14%; hypoxic-ischemic watershed injury in 2%, 1%, and 1%; intraparenchymal cerebral hemorrhage, in 0%, 4%, and 5%; cerebellar hemorrhage, in 6%, 2%, and 6%; intraventricular hemorrhage, in 14%, 6%, and 13%; subdural hemorrhage, in 29%, 17%, and 29%; and cerebral sinovenous thrombosis, in 0%, 10%, and 10%, respectively. CONCLUSIONS: A broad spectrum of perioperative brain MR imaging findings was found in infants with severe congenital heart disease. We propose an MR imaging protocol including T1-, T2-, diffusion-, and susceptibility-weighted imaging, and MRV to identify ischemic, hemorrhagic, and thrombotic lesions observed in this patient group

    The effect of titanium dioxide nanoparticles on pulmonary surfactant function and ultrastructure

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pulmonary surfactant reduces surface tension and is present at the air-liquid interface in the alveoli where inhaled nanoparticles preferentially deposit. We investigated the effect of titanium dioxide (TiO<sub>2</sub>) nanosized particles (NSP) and microsized particles (MSP) on biophysical surfactant function after direct particle contact and after surface area cycling <it>in vitro</it>. In addition, TiO<sub>2 </sub>effects on surfactant ultrastructure were visualized.</p> <p>Methods</p> <p>A natural porcine surfactant preparation was incubated with increasing concentrations (50-500 μg/ml) of TiO<sub>2 </sub>NSP or MSP, respectively. Biophysical surfactant function was measured in a pulsating bubble surfactometer before and after surface area cycling. Furthermore, surfactant ultrastructure was evaluated with a transmission electron microscope.</p> <p>Results</p> <p>TiO<sub>2 </sub>NSP, but not MSP, induced a surfactant dysfunction. For TiO<sub>2 </sub>NSP, adsorption surface tension (γ<sub>ads</sub>) increased in a dose-dependent manner from 28.2 ± 2.3 mN/m to 33.2 ± 2.3 mN/m (p < 0.01), and surface tension at minimum bubble size (γ<sub>min</sub>) slightly increased from 4.8 ± 0.5 mN/m up to 8.4 ± 1.3 mN/m (p < 0.01) at high TiO<sub>2 </sub>NSP concentrations. Presence of NSP during surface area cycling caused large and significant increases in both γ<sub>ads </sub>(63.6 ± 0.4 mN/m) and γ<sub>min </sub>(21.1 ± 0.4 mN/m). Interestingly, TiO<sub>2 </sub>NSP induced aberrations in the surfactant ultrastructure. Lamellar body like structures were deformed and decreased in size. In addition, unilamellar vesicles were formed. Particle aggregates were found between single lamellae.</p> <p>Conclusion</p> <p>TiO<sub>2 </sub>nanosized particles can alter the structure and function of pulmonary surfactant. Particle size and surface area respectively play a critical role for the biophysical surfactant response in the lung.</p

    Water-Soluble Fullerene (C60) Derivatives as Nonviral Gene-Delivery Vectors

    Get PDF
    A new class of water-soluble C60 transfecting agents has been prepared using Hirsch-Bingel chemistry and assessed for their ability to act as gene-delivery vectors in vitro. In an effort to elucidate the relationship between the hydrophobicity of the fullerene core, the hydrophilicity of the water-solubilizing groups, and the overall charge state of the C60 vectors in gene delivery and expression, several different C60 derivatives were synthesized to yield either positively charged, negatively charged, or neutral chemical functionalities under physiological conditions. These fullerene derivatives were then tested for their ability to transfect cells grown in culture with DNA carrying the green fluorescent protein (GFP) reporter gene. Statistically significant expression of GFP was observed for all forms of the C60 derivatives when used as DNA vectors and compared to the ability of naked DNA alone to transfect cells. However, efficient in vitro transfection was only achieved with the two positively charged C60 derivatives, namely, an octa-amino derivatized C60 and a dodeca-amino derivatized C60 vector. All C60 vectors showed an increase in toxicity in a dose-dependent manner. Increased levels of cellular toxicity were observed for positively charged C60 vectors relative to the negatively charged and neutral vectors. Structural analyses using dynamic light scattering and optical microscopy offered further insights into possible correlations between the various derivatized C60 compounds, the C60 vector/DNA complexes, their physical attributes (aggregation, charge) and their transfection efficiencies. Recently, similar Gd@C60-based compounds have demonstrated potential as advanced contrast agents for magnetic resonance imaging (MRI). Thus, the successful demonstration of intracellular DNA uptake, intracellular transport, and gene expression from DNA using C60 vectors suggests the possibility of developing analogous Gd@C60-based vectors to serve simultaneously as both therapeutic and diagnostic agents

    Automation of a problem list using natural language processing

    Get PDF
    BACKGROUND: The medical problem list is an important part of the electronic medical record in development in our institution. To serve the functions it is designed for, the problem list has to be as accurate and timely as possible. However, the current problem list is usually incomplete and inaccurate, and is often totally unused. To alleviate this issue, we are building an environment where the problem list can be easily and effectively maintained. METHODS: For this project, 80 medical problems were selected for their frequency of use in our future clinical field of evaluation (cardiovascular). We have developed an Automated Problem List system composed of two main components: a background and a foreground application. The background application uses Natural Language Processing (NLP) to harvest potential problem list entries from the list of 80 targeted problems detected in the multiple free-text electronic documents available in our electronic medical record. These proposed medical problems drive the foreground application designed for management of the problem list. Within this application, the extracted problems are proposed to the physicians for addition to the official problem list. RESULTS: The set of 80 targeted medical problems selected for this project covered about 5% of all possible diagnoses coded in ICD-9-CM in our study population (cardiovascular adult inpatients), but about 64% of all instances of these coded diagnoses. The system contains algorithms to detect first document sections, then sentences within these sections, and finally potential problems within the sentences. The initial evaluation of the section and sentence detection algorithms demonstrated a sensitivity and positive predictive value of 100% when detecting sections, and a sensitivity of 89% and a positive predictive value of 94% when detecting sentences. CONCLUSION: The global aim of our project is to automate the process of creating and maintaining a problem list for hospitalized patients and thereby help to guarantee the timeliness, accuracy and completeness of this information
    corecore