34 research outputs found

    Reduction of D-dimer levels after therapeutic administration of antithrombin in acquired antithrombin deficiency of severe sepsis

    Get PDF
    INTRODUCTION: In acute disseminated intravascular coagulation, the effect of antithrombin (AT) administration on elevated levels of D-dimer is not well established. In the present study, we report on changes in circulating levels of D-dimer in response to administration of AT in a series of patients with acquired AT deficiency due to severe sepsis. METHODS: Eight consecutive critically ill medical patients presenting with acute disseminated intravascular coagulation associated with severe sepsis/septic shock received a single bolus infusion of AT over 30 minutes, aiming to achieve physiological AT levels. Haemostatic parameters including D-dimer were assessed prior to, 6 and 24 h after AT administration. An average of 42 ± 9 U/kg body weight was infused. RESULTS: Following AT substitution, elevated levels of D-dimer fell whereas AT levels rose. CONCLUSION: These observations support the notion that AT can favourably affect fibrin degradation accompanying disseminated intravascular coagulation of severe sepsis

    Apoptotic Effects of Antilymphocyte Globulins on Human Pro-inflammatory CD4+CD28− T-cells

    Get PDF
    BACKGROUND: Pro-inflammatory, cytotoxic CD4(+)CD28(-) T-cells with known defects in apoptosis have been investigated as markers of premature immuno-senescence in various immune-mediated diseases. In this study we evaluated the influence of polyclonal antilymphocyte globulins (ATG-Fresenius, ATG-F) on CD4(+)CD28(-) T-cells in vivo and in vitro. PRINCIPAL FINDINGS: Surface and intracellular three colour fluorescence activated cell sorting analyses of peripheral blood mononuclear cells from 16 consecutive transplant recipients and short-term cell lines were performed. In vivo, peripheral levels of CD3(+)CD4(+)CD28(-) T-cells decreased from 3.7 ± 7.1% before to 0 ± 0% six hours after ATG-F application (P = 0.043) in 5 ATG-F treated but not in 11 control patients (2.9 ± 2.9% vs. 3.9 ± 3.0%). In vitro, ATG-F induced apoptosis even in CD4(+)CD28(-) T-cells, which was 4.3-times higher than in CD4(+)CD28(+) T-cells. ATG-F evoked apoptosis was partially reversed by the broad-spectrum caspase inhibitor benzyloxycarbonyl (Cbz)-Val-Ala-Asp(OMe)-fluoromethylketone (zVAD-fmk) and prednisolon-21-hydrogensuccinate. ATG-F triggered CD25 expression and production of pro-inflammatory cytokines, and induced down-regulation of the type 1 chemokine receptors CXCR-3, CCR-5, CX3CR-1 and the central memory adhesion molecule CD62L predominately in CD4(+)CD28(-) T-cells. CONCLUSION: In summary, in vivo depletion of peripheral CD3(+)CD4(+)CD28(-) T-cells by ATG-F in transplant recipients was paralleled in vitro by ATG-F induced apoptosis. CD25 expression and chemokine receptor down-regulation in CD4(+)CD28(-) T-cells only partly explain the underlying mechanism

    Reply

    No full text

    Reply

    No full text

    Reply

    No full text

    A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet)

    Get PDF
    AbstractObjectivesThis study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system—a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting.BackgroundThe risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period.MethodsA total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland.ResultsThe primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm3. The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm3) lesion in relation to the 48-h scan.ConclusionsThe use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period
    corecore