18 research outputs found

    Comparison of intra-individual coefficients of variation on the paired sampling data when inter-individual variations are different between measures

    Get PDF
    Additional file 2. Supplemental figures for the pain intensity data (residual plots, P–P plots and Cook’s distance against leverage/(1-leverage))

    Bacterial contamination upon the opening of injection needles

    No full text
    Abstract Introduction Two opening methods are used for injection needle products: the “peel-apart method” where the adhesive surface of the packaging mount is peeled off, and the “push-off top method,” where the needle hub is pressed against the mount to break it. However, the risks of bacterial contamination as a result of opening method remain unknown. The aim of our study was to evaluate the bacterial contamination of needle hubs upon the opening of injection needles by the peel-apart or push-off top method under various conditions. Methods Bacterial contamination upon the opening of injection needles was examined in two materials, paper and plastic. Various concentrations of Staphylococcus aureus were applied to the mount and were maintained under wet or dry conditions. Injection needles were opened using the peel-apart or push-off top method. Needle hub contamination was examined using agar medium colony counting. Clinically assumed conditions (the hands and saliva of anesthesiologists) were also evaluated. Data were statistically examined using the Cochran-Mantel-Haenszel, Jonckheere, and Fisher’s exact tests. Results The lateral surfaces of needle hubs were contaminated using the push-off top method, but not by the peel-apart method, in a manner that was dependent on S. aureus concentrations. No significant differences were observed between mount materials. Needle hub contamination was significantly more severe for the wet than for the dry opening portion. The clinically assumed condition study revealed that the lateral and bottom surfaces of the needle hub were contaminated significantly more in the saliva contamination group than in the dry and wet hand groups. Conclusions The bacterial contamination of needle hubs may occur upon the opening of injection needles when the push-off top method is used and may be affected by hands contaminated with saliva under clinical conditions

    Murine cell line SX9 bearing a mutation in the dna-pkcs gene exhibits aberrant V(D)J recombination not only in the coding joint but also in the signal joint.

    No full text
    We established the radiosensitive cell line SX9 from mammary carcinoma cell line FM3A. In SX9 cells a defect of DNA-dependent protein kinase (DNA-PK) activity was suggested. Additionally, a complementation test suggested that the SX9 cell line belongs to a x-ray cross-complementing group (XRCC) 7. Isolation and sequence analyses of DNA-dependent protein kinase catalytic subunit (dna-pkcs) cDNA in SX9 cells disclosed nucleotide "T" (9572) to "C" transition causing substitution of amino acid residue leucine (3191) to proline. Interestingly, the mutation occurs in one allele, and transcripts of the dna-pkcs expressed exclusively from mutated allele. V(D)J recombination assay using extrachromosomal vector revealed the defects of not only coding but also signal joint formation. The frequency of the signal joint decreased to approximately one-tenth and the fidelity drastically decreased to 12. 2% as compared with the normal cell line. To confirm the responsibility of the dna-pkcs gene for abnormal V(D)J recombination in SX9, the full-length dna-pkcs gene was introduced into SX9. As a result, restoration of V(D)J recombination by wild type dna-pkcs cDNA was observed. SX9 is a novel dna-pkcs-deficient cell line
    corecore