73 research outputs found

    Factual survey of the clinical use of deformable image registration software for radiotherapy in Japan

    Get PDF
    Deformable image registration (DIR) has recently become commercially available in the field of radiotherapy. However, there was no detailed information regarding the use of DIR software at each medical institution. Thus, in this study, we surveyed the status of the clinical use of DIR software for radiotherapy in Japan. The Japan Society of Medical Physics and the Japanese Society for Radiation Oncology mailing lists were used to announce this survey. The questionnaire was created by investigators working under the research grant of the Japanese Society for Radiation Oncology (2017–2018) and intended for the collection of information regarding the use of DIR in radiotherapy. The survey was completed by 161 institutions in Japan. The survey results showed that dose accumulation was the most frequent purpose for which DIR was used in clinical practice (73%). Various commissioning methods were performed, although they were not standardized. Qualitative evaluation with actual patient images was the most commonly used method (28%), although 30% of the total number of responses (42% of institutions) reported that they do not perform commissioning. We surveyed the current status of clinical use of DIR software for radiotherapy in Japan for the first time. Our results indicated that a certain number of institutions used DIR software for clinical practice, and various commissioning methods were performed, although they were not standardized. Taken together, these findings highlight the need for a technically unified approach for commissioning and quality assurance for the use of DIR software in Japan

    A virtual audit system for intensity-modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study

    Full text link
    PURPOSE The Medical Physics Working Group of the Radiation Therapy Study Group at the Japan Clinical Oncology Group is currently developing a virtual audit system for intensity-modulated radiation therapy dosimetry credentialing. The target dosimeters include films and array detectors, such as ArcCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA) and Delta4 (ScandiDos, Uppsala, Sweden). This pilot study investigated the feasibility of our virtual audit system using previously acquired data. METHODS We analyzed 46 films (32 and 14 in the axial and coronal planes, respectively) from 29 institutions. Global gamma analysis between measured and planned dose distributions used the following settings: 3%/3 mm criteria (the dose denominator was 2 Gy), 30% threshold dose, no scaling of the datasets, and 90% tolerance level. In addition, 21 datasets from nine institutions were obtained for array evaluation. Five institutions used ArcCHECK, while the others used Delta4. Global gamma analysis was performed with 3%/2 mm criteria (the dose denominator was the maximum calculated dose), 10% threshold dose, and 95% tolerance level. The film calibration and gamma analysis were conducted with in-house software developed using Python (version 3.9.2). RESULTS The means ± standard deviations of the gamma passing rates were 99.4 ± 1.5% (range, 92.8%-100%) and 99.2 ± 1.0% (range, 97.0%-100%) in the film and array evaluations, respectively. CONCLUSION This pilot study demonstrated the feasibility of virtual audits. The proposed virtual audit system will contribute to more efficient, cheaper, and more rapid trial credentialing than on-site and postal audits; however, the limitations should be considered when operating our virtual audit system

    Survey of imaging dose in HDR brachytherapy

    Get PDF
    Institutional imaging protocols for the verification of brachytherapy applicator placements were investigated in a survey study of domestic radiotherapy institutions. The survey form designed by a free on-line survey system was distributed via the mailing-list system of the Japanese Society for Radiation Oncology. Survey data of 75 institutions between August 2019 and October 2019 were collected. The imaging modalities used were dependent on resources available to the institutions. The displacement of a brachytherapy applicator results in significant dosimetric impact. It is essential to verify applicator placements using imaging modalities before treatment. Various imaging modalities used in institutions included a computed tomography (CT) scanner, an angiography X-ray system, a multi-purpose X-ray system and a radiotherapy simulator. The median total exposure time in overall treatment sessions was ≤75 s for gynecological and prostate cancers. Some institutions used fluoroscopy to monitor the brachytherapy source movement. Institutional countermeasures for reducing unwanted imaging dose included minimizing the image area, changing the imaging orientation, reducing the imaging frequency and optimizing the imaging conditions. It is worth noting that half of the institutions did not confirm imaging dose regularly. This study reported on the usage of imaging modalities for brachytherapy in Japan. More caution should be applied with interstitial brachytherapy with many catheters that can lead to potentially substantial increments in imaging doses for monitoring the actual brachytherapy source using fluoroscopy. It is necessary to share imaging techniques, standardize imaging protocols and quality assurance/quality control among institutions, and imaging dose guidelines for optimization of imaging doses delivered in radiotherapy should be developed

    Clinical Outcome of Patients with Pelvic and Retroperitoneal Bone and Soft Tissue Sarcoma : A Retrospective Multicenter Study in Japan

    Get PDF
    This study aimed to retrospectively analyze the clinical outcomes of patients with pelvic and retroperitoneal bone and soft tissue sarcoma (BSTS). Overall, 187 patients with BSTS in the pelvis and retroperitoneal region treated at 19 specialized sarcoma centers in Japan were included. The prognostic factors related to overall survival (OS), local control (LC), and progression-free survival (PFS) were evaluated. The 3-year OS and LC rates in the 187 patients were 71.7% and 79.1%, respectively. The 3-year PFS in 166 patients without any distant metastases at the time of primary tumor diagnosis was 48.6%. Osteosarcoma showed significantly worse OS and PFS than other sarcomas of the pelvis and retroperitoneum. In the univariate analyses, larger primary tumor size, soft tissue tumor, distant metastasis at the time of primary tumor diagnosis, P2 location, chemotherapy, and osteosarcoma were poor prognostic factors correlated with OS. Larger primary tumor size, higher age, soft tissue tumor, chemotherapy, and osteosarcoma were poor prognostic factors correlated with PFS in patients without any metastasis at the initial presentation. Larger primary tumor size was the only poor prognostic factor correlation with LC. This study has clarified the epidemiology and prognosis of patients with pelvic and retroperitoneal BSTS in Japan

    Granisetron plus aprepitant versus granisetron in preventing nausea and vomiting during CHOP or R-CHOP regimen in malignant lymphoma: a retrospective study.

    Get PDF
    Background:Cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) regimen includes a high dose of prednisolone (100 mg/body), which exhibits an anticancer and antiemetic effect. However, its optimal use for antiemetic therapy has not been established yet. We assessed the efficacy of granisetron plus aprepitant versus granisetron for CHOP or rituximab-CHOP (R-CHOP) regimen-induced nausea and vomiting in malignant lymphoma.Methods:This retrospective and observational clinical study included patients who received CHOP or R-CHOP regimen as initiating chemotherapy between July 2010 and March 2016 (N = 39). Patients were assigned to an aprepitant [aprepitant (125 mg on day 1, 80 mg on days 2-3) plus granisetron (3 mg); n = 15] or control regimen group [granisetron (3 mg); n = 24]. Complete response (CR), defined as no vomiting and no use of rescue therapy during overall phase (0-120 h), was the primary endpoint. Secondary endpoints included the time to first vomiting and using rescue medication and complete protection (CP) defined as no vomiting and no retching and/or no nausea and no rescue therapy. The patient records were investigated, and data were retrospectively analyzed.Results:CR rate CP rates did not significantly differ between the groups during the observation period (80.0% versus 83.3%, p = 1.000; and 80.0% versus 79.2%, p = 1.000, respectively). Additionally, the time to first vomiting and using rescue medication in did not significantly differ between the groups (p = 0.909).Conclusions:This study suggests that granisetron alone could be one treatment option in the management of CINV in patients with non-Hodgkin lymphoma receiving CHOP or R-CHOP regimen
    corecore