13 research outputs found

    Cross-reactive epitopes and their role in food allergy

    Get PDF
    Allergenic cross-reactivity among food allergens complicates the diagnosis and management of food allergy. This can result in many patients being sensitized (having allergen-specific IgE) to foods without exhibiting clinical reactivity. Some food groups such as shellfish, fish, tree nuts, and peanuts have very high rates of cross-reactivity. In contrast, relatively low rates are noted for grains and milk, whereas many other food families have variable rates of cross-reactivity or are not well studied. Although classical cross-reactive carbohydrate determinants are clinically not relevant, α-Gal in red meat through tick bites can lead to severe reactions. Multiple sensitizations to tree nuts complicate the diagnosis and management of patients allergic to peanut and tree nut. This review discusses cross-reactive allergens and cross-reactive carbohydrate determinants in the major food groups, and where available, describes their B-cell and T-cell epitopes. The clinical relevance of these cross-reactive B-cell and T-cell epitopes is highlighted and their possible impact on allergen-specific immunotherapy for food allergy is discussed

    Periodontal Tissue Regeneration Using Fibroblast Growth Factor -2: Randomized Controlled Phase II Clinical Trial

    Get PDF
    Background: The options for medical use of signaling molecules as stimulators of tissue regeneration are currently limited. Preclinical evidence suggests that fibroblast growth factor (FGF)-2 can promote periodontal regeneration. This study aimed to clarify the activity of FGF-2 in stimulating regeneration of periodontal tissue lost by periodontitis and to evaluate the safety of such stimulation. Methodology/Principal Findings: We used recombinant human FGF-2 with 3% hydroxypropylcellulose (HPC) as vehicle and conducted a randomized double-blinded controlled trial involving 13 facilities. Subjects comprised 74 patients displaying a 2- or 3-walled vertical bone defect as measured ?3 mm apical to the bone crest. Patients were randomly assigned to 4 groups: Group P, given HPC with no FGF-2; Group L, given HPC containing 0.03% FGF-2; Group M, given HPC cotaining 0.1% FGF-2; and Group H, given HPC Containing 0.3% FGF-2. Each patient underwent flap operation during which we administered 200 μL of the appropriate investigational drug to the bone defect. Before and for 36 weeks following administration, patients underwent periodontal tissue inspections and standardized radiography of the region under investigation. As a result, a significant difference (p = 0.021) in rate of increase in alveolar bone height was identified between Group P (23.92%) and Group H (58.62%) at 36 weeks. The linear increase in alveolar bone height at 36 weeks in Group P and H was 0.95 mm and 1.85 mm, respectively (p = 0.132). No serious adverse events attribute to the investigational drug were identified. Conclusions: Although no statistically significant differences were noted for gains in clinical attachment level and alveolar bone gain for FGF-2 groups versus Group P, the significant difference in rate of increase in alveolar bone height (p = 0.021) between Groups P and H at 36 weeks suggests that some efficacy could be expected from FGF-2 in stimulating regeneration of periodontal tissue in patients with periodontitis

    The CALET, CALorimetric Electron Telescope, Mission for the International Space Station

    No full text
    The CALorimetric Electron Telescope, CALET, mission is proposed for the Japanese Experiment Module Exposure Facility of the International Space Station. Major goals of the mission are precise measurements of the electrons in a few GeV - 10 TeV and the gamma-rays in 100 MeV - several TeV, keeping an energy resolution of a few % over 100 GeV. From the measurements, a systematic investigation of high-energy electromagnetic process in universe will be performed. A detector of SUSY particle which is a candidate of the dark matter would also be expected. The detector is composed of an imaging calorimeter of scinillating fibers and a total absorption calorimeter. Total thickness of absorber is 45 r.l for electron-magnetic particles and 2.1 m.f.p for protons. Total weight of the payload is nearly 2,200 kg, and the effective geometrical factor should be ~ 1.0 m2 sr. The hadron rejection power can be 10**6 for electrons
    corecore