1,355 research outputs found

    Silver-Zinc Battery Separator Material Development

    Get PDF
    Ethylene/acrylic acid separators for silver zinc battery application

    Cryo-Electron Ptychography: Applications and Potential in Biological Characterisation

    Full text link
    There is a clear need for developments in characterisation techniques that provide detailed information about structure-function relationships in biology. Using electron microscopy to achieve high resolution while maintaining a broad field of view remains a challenge, particularly for radiation sensitive specimens where the signal-to-noise ratio required to maintain structural integrity is limited by low electron fluence. In this review, we explore the potential of cryogenic electron ptychography as an alternative method for characterisation of biological systems under low fluence conditions. Using this method with increased information content from multiple sampled regions of interest, potentially allows 3D reconstruction with far fewer particles than required in conventional cryo-electron microscopy. This is important for achieving higher resolution for systems where distributions of homogeneous single particles are difficult to obtain. We discuss the progress, limitations and potential areas for future development of this approach for both single particle analysis and in applications to heterogeneous large objects

    Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons

    Full text link
    In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imagin

    Characterisation of the Medipix3 detector for 60 and 80 keV electrons

    Get PDF
    In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies &lt;100 keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging

    Detectors—The ongoing revolution in scanning transmission electron microscopy and why this important to material characterization

    Get PDF
    Detectors are revolutionizing possibilities in scanning transmission electron microscopy because of the advent of direct electron detectors that record at a high quantum efficiency and with a high frame rate. This allows the whole back focal plane to be captured for each pixel in a scan and the dataset to be processed to reveal whichever features are of interest. There are many possible uses for this advance of direct relevance to understanding the nano- and atomic-scale structure of materials and heterostructures. This article gives our perspective of the current state of the field and some of the directions where it is likely to go next. First, a wider overview of the recent work in this area is given before two specific examples of its application are given: one is imaging strain in thin films and the other one is imaging changes in periodicity along the beam direction as a result of the formation of an ordered structure in an epitaxial thin film. This is followed by an outlook that presents future possible directions in this rapidly expanding field

    New Dromaeosaurids (Dinosauria: Theropoda) from the Lower Cretaceous of Utah, and the Evolution of the Dromaeosaurid Tail

    Get PDF
    Background: The Yellow Cat Member of the Cedar Mountain Formation (Early Cretaceous, Barremian? – Aptian) of Utah has yielded a rich theropod fauna, including the coelurosaur Nedcolbertia justinhofmanni, the therizinosauroid Falcarius utahensis, the troodontid Geminiraptor suarezarum, and the dromaeosaurid Utahraptor ostrommaysorum. Recent excavation has uncovered three new dromaeosaurid specimens. One specimen, which we designate the holotype of the new genus and species Yurgovuchia doellingi, is represented by a partial axial skeleton and a partial left pubis. A second specimen consists of a right pubis and a possibly associated radius. The third specimen consists of a tail skeleton that is unique among known Cedar Mountain dromaeosaurids. Methodology/Principal Findings: Y. doellingi resembles Utahraptor ostrommaysorum in that its caudal prezygapophyses are elongated but not to the degree present in most dromaeosaurids. The specimen represented by the right pubis exhibits a pronounced pubic tubercle, a velociraptorine trait that is absent in Y. doellingi. The specimen represented by the tail skeleton exhibits the extreme elongation of the caudal prezygapophyses that is typical of most dromaeosaurids. Here we perform a phylogenetic analysis to determine the phylogenetic position of Y. doellingi. Using the resulting phylogeny as a framework, we trace changes in character states of the tail across Coelurosauria to elucidate the evolution of the dromaeosaurid tail. Conclusions/Significance: The new specimens add to the known diversity of Dromaeosauridae and to the known diversity within the Yellow Cat paleofauna. Phylogenetic analysis places Y. doellingi in a clade with Utahraptor, Achillobator, and Dromaeosaurus. Character state distribution indicates that the presence of intermediate-length caudal prezygapophyses in that clade is not an evolutionarily precursor to extreme prezygapophyseal elongation but represents a secondary shortening of caudal prezygapophyses. It appears to represent part of a trend within Dromaeosauridae that couples an increase in tail flexibility with increasing size

    Direct detection of electron backscatter diffraction patterns.

    No full text
    We report the first use of direct detection for recording electron backscatter diffraction patterns. We demonstrate the following advantages of direct detection: the resolution in the patterns is such that higher order features are visible; patterns can be recorded at beam energies below those at which conventional detectors usefully operate; high precision in cross-correlation based pattern shift measurements needed for high resolution electron backscatter diffraction strain mapping can be obtained. We also show that the physics underlying direct detection is sufficiently well understood at low primary electron energies such that simulated patterns can be generated to verify our experimental data

    Silver-Zinc Battery Separator Material Development

    Get PDF
    Ethylene/methyl acrylate copolymer synthesis for silver-zinc battery separator
    • …
    corecore