9,853 research outputs found

    Vehicular Causation Factors and Conceptual Design Modifications to Reduce Aortic Strain in Numerically Reconstructed Real World Nearside Lateral Automotive Crashes

    Get PDF
    Aortic injury (AI) leading to disruption of the aorta is an uncommon but highly lethal consequence of trauma in modern society. Most recent estimates range from 7,500 to 8,000 cases per year from a variety of causes. It is observed that more than 80% of occupants who suffer an aortic injury die at the scene due to exsanguination into the chest cavity. It is evident that effective means of substantially improving the outcome of motor vehicle crash-induced AIs is by preventing the injury in the first place. In the current study, 16 design of computer experiments (DOCE) were carried out with varying levels of principal direction of force (PDOF), impact velocity, impact height, and impact position of the bullet vehicle combined with occupant seating positions in the case vehicle to determine the effects of these factors on aortic injury. Further, a combination of real world crash data reported in the Crash Injury Research and Engineering Network (CIREN) database, Finite Element (FE) vehicle models, and the Wayne State Human Body Model-II (WSHBM-II) indicates that occupant seating position, impact height, and PDOF, in that order play, a primary role in aortic injury

    Biomechanics of the Neck

    Get PDF

    Why Is CA3 More Vulnerable Than CA1 in Experimental Models of Controlled Cortical Impact-Induced Brain Injury?

    Get PDF
    One interesting finding of controlled cortical impact (CCI) experiments is that the CA3 region of the hippocampus, which is positioned further from the impact than the CA1 region, is reported as being more injured. The current literature has suggested a positive correlation between brain tissue stretch and neuronal cell loss. However, it is counterintuitive to assume that CA3 is stretched more during CCI injury. Recent mechanical studies of the brain have reported on a level of spatial heterogeneity not previously appreciated—the finding that CA1 was significantly stiffer than all other regions tested and that CA3 was one of the most compliant. We hypothesized that mechanical heterogeneity of anatomical structures could underlie the proposed heterogeneous mechanical response and hence the pattern of cell death. As such, we developed a three-dimensional finite element (FE) rat brain model representing detailed hippocampal structures and simulated various CCI experiments. Four groups of material properties based on recent experiments were tested. In group 1, hyperelastic material properties were assigned to various hippocampal structures, with CA3 more compliant than CA1. In group 2, linear viscoelastic material properties were assigned to hippocampal structures, with CA3 more com- pliant than CA1. In group 3, the hippocampus was represented by homogenous linear viscoelastic material properties. In group 4, a homogeneous nonlinear hippocampus was adopted. Simulation results demonstrated that for CCI with a 5-mm diameter, flat shape impactor, CA3 experienced increased tensile strains over a larger area and to a greater magnitude than did CA1 for group 1, which best explained why CA3 is more sensitive to CCI injury. However, for groups 2-4, the total volume with high strain (\u3e 30%) in CA3 was smaller than that in CA1. The FE rat brain model, with detailed hippocampal structures presented here, will help to engineer desired experimental neurotrauma models by virtually characterizing brain biomechanics before testing

    Towards a More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies

    Get PDF
    Objective.The compressive tolerance of the cervical spine has traditionally been reported in terms of axial force at failure. Previous studies suggest that axial compressive force at failure is particularly sensitive to the alignment of the cervical vertebra and the end conditions of the test methodology used. The present study was designed to develop a methodology to combine the data of previous experiments into a diverse dataset utilizing multiple test methods to allow for the evaluation of the robustness of current and proposed eccentricity based injury criteria. Methods. Data was combined from two studies composed of dynamic experiments including whole cervical spine and head kinematics that utilized different test methodologies with known end conditions, spinal posture, injury outcomes and measured kinetics at the base of the neck. Loads were transformed to the center of the C7-T1 intervertebral disc and the eccentricity of the sagittal plane resultant force relative to the center of the disc was calculated. The correlation between sagittal plane resultant force and eccentricity at failure was evaluated and compared to the correlation between axial force and sagittal plane moment and axial force alone. Results. Accounting for the eccentricity of the failure loads decreased the scatter in the failure data when compared to the linear combination of axial force and sagittal plane moment and axial force alone. A correlation between axial load and sagittal plane flexion moment at failure (R2 = 0.44) was identified. The sagittal plane extension moment at failure did not have an identified correlation with the compressive failure load for the tests evaluated in this data set (R2 = 0.001). The coefficients of determination for the linear combinations of sagittal plane resultant force with anterior and posterior eccentricity are 0.56 and 0.29 respectively. These correlations are an improvement compared to the combination of axial force and sagittal plane moment. Conclusions. Results using the outlined approach indicate that the combination of lower neck sagittal plane resultant force and the anterior-posterior eccentricity at which the load is applied generally correlate with the type of cervical damage identified. These results show promise at better defining the tolerance for compressive cervical fractures in male Post Mortem Human Subjects (PMHS) than axial force alone. The current analysis requires expansion to include more tolerance data so the robustness of the approach across various applied loading vectors and cervical postures can be evaluated

    Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures

    Get PDF
    Abstract Background We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Methods Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons Results The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Conclusions Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used

    Rural Redemption: A Model to Help Understand the Perspectives of Rural Americans Related to Vaccine Science

    Get PDF
    Rural communities are vital to the foundation of American agriculture and are currently disproportionately affected by health and environmental challenges that will require broad scientific solutions. Cooperative Extension professionals and agricultural communicators are increasingly tasked with communicating about the science surrounding these topics and need effective tools for determining strategic communication tactics to influence personal behaviors. The purpose of this study was to understand the role of community-based social marketing (CBSM) concepts and trust in science on rural Americans’ intentions and attitudes toward the COVID-19 vaccine. A hypothesized model was developed that included concepts of CBSM, trust in science, intentions, and attitudes all related to the COVID-19 vaccine. Results showed that CBSM principles had significant explanatory power for predicting intentions to receive the COVID-19 vaccine. CBSM and trust in science were also significant predictors of rural Americans attitudes toward the COVID-19 vaccine. Implications for this study reveal a need for future research and practice related to communicating about science and vaccines to rural Americans while building community-based principles for increasing trust and advancing perceptions of science. Future research should determine the impact of CBSM and trust in science on the end-state behavior of receiving the vaccine. Additionally, Extension professionals and agricultural communicators should prioritize CBSM concepts when developing programming and messages related to health behaviors

    Governance of Offshore IT Outsourcing at Shell Global Functions IT-BAM Development and Application of a Governance Framework to Improve Outsourcing Relationships

    Get PDF
    The lack of effective IT governance is widely recognized as a key inhibitor to successful global IT outsourcing relationships. In this study we present the development and application of a governance framework to improve outsourcing relationships. The approach used to developing an IT governance framework includes a meta model and a customization process to fit the framework to the target organization. The IT governance framework consists of four different elements (1) organisational structures, (2) joint processes between in- and outsourcer, (3) responsibilities that link roles to processes and (4) a diverse set of control indicators to measure the success of the relationship. The IT governance framework is put in practice in Shell GFIT BAM, a part of Shell that concluded to have a lack of management control over at least one of their outsourcing relationships. In a workshop the governance framework was used to perform a gap analysis between the current and desired governance. Several gaps were identified in the way roles and responsibilities are assigned and joint processes are set-up. Moreover, this workshop also showed the usefulness and usability of the IT governance framework in structuring, providing input and managing stakeholders in the discussions around IT governance

    Neutrino Mass and Grand Unification

    Full text link
    Seesaw mechanism appears to be the simplest and most appealing way to understand small neutrino masses observed in recent experiments. It introduces three right handed neutrinos with heavy masses to the standard model, with at least one mass required by data to be close to the scale of conventional grand unified theories. This may be a hint that the new physics scale implied by neutrino masses and grand unification of forces are one and the same. Taking this point of view seriously, I explore different ways to resolve the puzzle of large neutrino mixings in grand unified theories such as SO(10) and models based on its subgroup SU(2)LĂ—SU(2)RĂ—SU(4)cSU(2)_L\times SU(2)_R\times SU(4)_c.Comment: 17 pages, 5 figures; Invited talk at the Nobel Symposium 129 on Neutrinos at Haga Slott, Sweden, August, 200
    • …
    corecore