279 research outputs found

    Field modulation in Na-incorporated Cu(In,Ga)Se2 (CIGS) polycrystalline films influenced by alloy-hardening and pair-annihilation probabilities

    Get PDF
    The influence of Na on Cu(In,Ga)Se2 (CIGS) solar cells was investigated. A gradient profile of the Na in the CIGS absorber layer can induce an electric field modulation and significantly strengthen the back surface field effect. This field modulation originates from a grain growth model introduced by a combination of alloy-hardening and pair-annihilation probabilities, wherein the Cu supply and Na diffusion together screen the driving force of the grain boundary motion (GBM) by alloy hardening, which indicates a specific GBM pinning by Cu and Na. The pair annihilation between the ubiquitously evolving GBMs has a coincident probability with the alloy-hardening event

    Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

    Get PDF
    Background A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6–210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture

    Antitumorigenic effect of atmospheric-pressure dielectric barrier discharge on human colorectal cancer cells via regulation of Sp1 transcription factor

    Get PDF
    Human colorectal cancer cell lines (HT29 and HCT116) were exposed to dielectric barrier discharge (DBD) plasma at atmospheric pressure to investigate the anticancer capacity of the plasma. The dose- and time-dependent effects of DBDP on cell viability, regulation of transcription factor Sp1, cell-cycle analysis, and colony formation were investigated by means of MTS assay, DAPI staining, propidium iodide staining, annexin V-FITC staining, Western blot analysis, RT-PCR analysis, fluorescence microscopy, and anchorage-independent cell transformation assay. By increasing the duration of plasma dose times, significant reductions in the levels of both Sp1 protein and Sp1 mRNA were observed in both cell lines. Also, expression of negative regulators related to the cell cycle (such as p53, p21, and p27) was increased and of the positive regulator cyclin D1 was decreased, indicating that the plasma treatment led to apoptosis and cell-cycle arrest. In addition, the sizes and quantities of colony formation were significantly suppressed even though two cancer promoters, such as TPA and epidermal growth factor, accompanied the plasma treatment. Thus, plasma treatment inhibited cell viability and colony formation by suppressing Sp1, which induced apoptosis and cell-cycle arrest in these two human colorectal cancer cell lines.1

    Association between Positional Dependency and Obstruction Site in Obstructive Sleep Apnea Syndrome

    Get PDF
    ObjectivesThe purpose of this study is to find out associations between positional dependency and obstructive levels based on sleep videofluoroscopy (SVF) in patients with obstructive sleep apnea syndrome (OSAS).MethodsRetrospective review was made of 91 OSAS patients who underwent polysomnography and SVF from August 2009 through June 2010. Polysomnography variables including apnea-hypopnea index (AHI), supine AHI, non-supine AHI, time spent in supine sleep position of the total sleep time and positional dependency (PD) were analyzed. Obstruction sites were evaluated as SVF variables.ResultsOf 91 patients, 65 (71.4%) were positional patients (PP) and 26 (28.6%) were non-positional patients (NPP). An analysis of polysomnography variables according to PD revealed that overall AHI, non-supine AHI and supine AHI in PP was significantly lower than that in NPP. The patients with soft palate obstruction (SP type) were more likely to have PD than the patients with tongue base obstruction (TB type; P=0.046). PD was inversely related to OSAS severity significantly (P=0.001).ConclusionThese results provide evidence that positional dependent patients may have higher success rate of soft palate OSA surgery alone than non-positional dependent patients. Although PD may be associated with obstruction site, PD only itself may not be useful in planning surgical treatment for OSAS

    Intra-Arterial Thrombolysis after Full-Dose Intravenous tPA via the "Drip and Ship" Approach in Patients with Acute Ischemic Stroke: Preliminary Report

    Get PDF
    According to the "drip and ship" concept, patients who are not responsive to intravenous tissue plasminogen activator (IV-tPA) at a community hospital may be candidates for subsequent intra-arterial (IA) thrombolysis at a comprehensive stroke center. We elucidated the efficacy and safety of combined IV/IA thrombolysis via the drip and ship approach. We retrospectively reviewed patients with acute ischemic stroke who underwent combined IV/IA thrombolysis between March 2006 and June 2009. The patients were divided into two groups (inside hospital IV-tPA vs. outside hospital IV-tPA). We compared the short- and long-term clinical outcome, recanalization rate, intracranial hemorrhage after the procedure, and onset to treatment time between the two groups. A total of 23 patients with inside hospital IV-tPA and 10 patients with outside hospital IV-tPA were included. The mean pre-treatment National Institutes of Health Stroke Scale (NIHSS) scores were 15.8 and 17.5, respectively. Baseline characteristics were not significantly different between the two groups. The NIHSS score at 1 week and favorable outcome rate (modified Rankin Scale ≤2) 3 months after the procedure were not significantly different (p=0.730 and p=0.141, respectively). The rate of recanalization and intracranial hemorrhage were not significantly different (p=0.560 and p=0.730, respectively). The onset to IA thrombolysis time was also not significantly different (222.7 vs. 239.3 minutes, p=0.455). Our results suggest that initiation of IV-tPA in a community hospital with rapid transfer to a comprehensive stroke center for subsequent IA thrombolysis can be a safe and feasible therapeutic option in acute stroke management

    Safety and Efficacy of Second-Generation Everolimus-Eluting Xience V Stents Versus Zotarolimus-Eluting Resolute Stents in Real-World Practice Patient-Related and Stent-Related Outcomes From the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries

    Get PDF
    ObjectivesThis study sought to compare the safety and efficacy of the Xience V/Promus everolimus-eluting stent (EES) (Abbott Vascular, Temecula, California) with the Endeavor Resolute zotarolimus-eluting stent (ZES-R) (Medtronic Cardiovascular, Santa Rosa, California) in “all-comer” cohorts.BackgroundOnly 2 randomized controlled trials have compared these stents.MethodsThe EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with the EES and 1,998 patients treated with the ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure [TLF]) and patient-related composite outcomes were compared in crude and propensity score-matched analyses.ResultsOf 5,054 patients, 3,830 (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (82 [2.7%] vs. 58 [2.9%], p = 0.662) and the patient-related outcome (225 [7.4%] vs. 153 [7.7%], p = 0.702) did not differ between EES and ZES-R, respectively, at 1 year, which was corroborated by similar results from the propensity score-matched cohort. The rate of definite or probable stent thrombosis (18 [0.6%] vs. 7 [0.4%], p = 0.306) also was similar. In multivariate analysis, off-label indication was the strongest predictor of TLF (adjusted hazard ratio: 2.882; 95% confidence interval: 1.226 to 6.779; p = 0.015).ConclusionsIn this robust real-world registry with unrestricted use of EES and ZES-R, both stents showed comparable safety and efficacy at 1-year follow-up. Overall incidences of TLF and definite stent thrombosis were low, even in the patients with off-label indication, suggesting excellent safety and efficacy of both types of second-generation drug-eluting stents
    corecore