563 research outputs found
Performance of the active sidewall boundary-layer removal system for the Langley 0.3-meter Transonic Cryogenic Tunnel
A performance evaluation of an active sidewall boundary-layer removal system for the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) was evaluated in 1988. This system uses a compressor and two throttling digital valves to control the boundary-layer mass flow removal from the tunnel. The compressor operates near the maximum pressure ratio for all conditions. The system uses a surge prevention and flow recirculation scheme. A microprocessor based controller is used to provide the necessary mass flow and compressor pressure ratio control. Initial tests on the system indicated problems in realizing smooth mass flow control while running the compressor at high speed and high pressure ratios. An alternate method has been conceived to realize boundary-layer mass flow control which avoids the recirculation of the compressor mass flow and operation near the compressor surge point. This scheme is based on varying the speed of the compressor for a sufficient pressure ratio to provide needed mass flow removal. The system has a mass flow removal capability of about 10 percent of test section flow at M = 0.3 and 4 percent at M = 0.8. The system performance has been evaluated in the form of the compressor map, and compressor tunnel interface characteristics covering most of the 0.3-m TCT operational envelope
A feasibility study of using Langley 0.3-m transonic cryogenic tunnel sidewall boundary-layer removal system for heavy gas testing
This report presents the results of a preliminary study for using the 0.3-m Transonic Cryogenic Tunnel sidewall boundary-layer removal system with heavy gas sulfur hexafluoride as the test medium. It is shown that the drive motor speed/power of the existing system and the additional heat load on the tunnel heat exchanger are the major problems limiting the boundary-layer removal system performance. Overcoming these problems can provide the capability to remove about 1.5 percent of the test section mass flow at Mach number M = 0.8 and about 5 percent at M = 0.25. Previous studies have shown that these boundary-layer mass flow removal rates can reduce the boundary-layer thickness by a factor of two at the model station. Also the effect of upstream boundary-layer removal on the airfoil test data is not likely to be significant under high lifting conditions. Near design conditions, corrections to the test Mach number may be necessary to account for sidewall boundary-layer effects
Welding, brazing, and soldering handbook
Handbook gives information on the selection and application of welding, brazing, and soldering techniques for joining various metals. Summary descriptions of processes, criteria for process selection, and advantages of different methods are given
Pilot weather advisor
The results of the work performed by ViGYAN, Inc., to demonstrate the Pilot Weather Advisor cockpit weather data system using a broadcast satellite communication system are presented. The Pilot Weather Advisor demonstrated that the technical problems involved with transmitting significant amount of weather data to an aircraft in-flight or on-the-ground via satellite are solvable with today's technology. The Pilot Weather Advisor appears to be a viable solution for providing accurate and timely weather information for general aviation aircraft
Full-scale aircraft simulation with cryogenic tunnels and status of the National Transonic Facility
The effect of thermal and caloric imperfections in cryogenic nitrogen on boundary layers was determined to indicate that in order to simulate nonadiabatic laminar or turbulent boundary layers in a cryogenic nitrogen wind tunnel, the flight enthalpy ratio, rather than the temperature ratio, should be reproduced. The absence of significant real gas effects on both viscous and inviscid flows makes it unlikely that there will be large real gas effects on the cryogenic tunnel simulation of shock boundary layer interactions or other complex flow conditions encountered in flight. Condensation effects were studied to determine the minimum usable temperature and indicated that under most circumstances free stream Mach number rather than maximum local Mach number determines the onset of condensation effects
Recent Enhancements to the National Transonic Facility (Mixed Mode Operations)
The U.S. National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the development of a Mixed-mode of operations that combine Air-mode operations with Nitrogen-mode operations. This implementation and operational results of this new Mixed-mode expands the ambient temperature transonic region of testing beyond the Air-mode limitations at a significantly reduced cost over Nitrogen Mode operation
Snowmass 2001: Jet Energy Flow Project
Conventional cone jet algorithms arose from heuristic considerations of LO
hard scattering coupled to independent showering. These algorithms implicitly
assume that the final states of individual events can be mapped onto a unique
set of jets that are in turn associated with a unique set of underlying hard
scattering partons. Thus each final state hadron is assigned to a unique
underlying parton. The Jet Energy Flow (JEF) analysis described here does not
make such assumptions. The final states of individual events are instead
described in terms of flow distributions of hadronic energy. Quantities of
physical interest are constructed from the energy flow distribution summed over
all events. The resulting analysis is less sensitive to higher order
perturbative corrections and the impact of showering and hadronization than the
standard cone algorithms.Comment: REVTeX4, 13 pages, 6 figures; Contribution to the P5 Working Group on
QCD and Strong Interactions at Snowmass 200
Exact N3LO results for qq ′ → H + X
We compute the contribution to the total cross section for the inclusive production of a Standard Model Higgs boson induced by two quarks with different flavour in the initial state. Our calculation is exact in the Higgs boson mass and the partonic center-of-mass energy. We describe the reduction to master integrals, the construction of a canonical basis, and the solution of the corresponding differential equations. Our analytic result contains both Harmonic Polylogarithms and iterated integrals with additional letters in the alphabet. © 2015, The Author(s)
Analysis of Flow Angularity Repeatability Tests in the NTF
An extensive data base of flow angularity repeatability measurements from four NTF check standard model tests is analyzed for statistical consistency and to characterize the results for prediction of angle-of-attack uncertainty for customer tests. A procedure for quality assurance for flow angularity measurements during customer tests is also presented. The efficacy of the procedure is tested using results from a customer test
Next-to-Next-to-Leading Order Higgs Production at Hadron Colliders
The Higgs boson production cross section at pp and p\bar{p} colliders is
calculated in QCD at next-to-next-to-leading order (NNLO). We find that the
perturbative expansion of the production cross section is well behaved and that
scale dependence is reduced relative to the NLO result. These findings give us
confidence in the reliability of the prediction. We also report an error in the
NNLO correction to Drell-Yan production.Comment: 5 pages, 4 figures, minor change
- …