    Novel Monte Carlo dose calculation algorithm for robotic radiosurgery with multi leaf collimator: Dosimetric evaluation

    No full text
    Purpose: At introduction in 2014, dose calculation for the first MLC on a robotic SRS/SBRT platform was limited to a correction-based Finite-Size Pencil Beam (FSPB) algorithm. We report on the dosimetric accuracy of a novel Monte Carlo (MC) dose calculation algorithm for this MLC, included in the Precision (TM) treatment planning system. Methods: A phantom was built of one slab (5.0 cm) of lung-equivalent material (0.09...0.29 g/cc) enclosed by 3.5 cm (above) and 5 cm (below) slabs of solid water (1.045 g/cc). This was irradiated using rectangular (15.4 x 15.4 mm(2) to 53.8 x 53.7 mm(2)) and two irregular MLC-fields. Radiochromic film (EBT3) was positioned perpendicular to the slabs and parallel to the beam. Calculated dose distributions were compared to film measurements using line scans and 2D gamma analysis. Results: Measured and MC calculated percent depth dose curves showed a characteristic dose drop within the low-density region, which was not correctly reproduced by FSPB. Superior average gamma pass rates (2%/1 mm) were found for MC (91.2 +/- 1.5%) compared to FSPB (55.4 +/- 2.7%). However, MC calculations exhibited localized anomalies at mass density transitions around 0.15 g/cc, which were traced to a simplification in electron transport. Absence of these anomalies was confirmed in a modified build of the MC engine, which increased gamma pass rates to 96.6 +/- 1.2%. Conclusions: The novel MC algorithm greatly improves dosimetric accuracy in heterogeneous tissue, potentially expanding the clinical use of robotic radiosurgery with MLC. In-depth, independent validation is paramount to identify and reduce the residual uncertainties in any software solution

    A novel external/internal tumor tracking approach to compensate for respiratory motion baseline drifts

    No full text
    Objective. Real-time respiratory tumor tracking as implemented in a robotic treatment unit is based on continuous optical measurement of the position of external markers and a correlation model between them and internal target positions, which are established with X-ray imaging of the tumor, or fiducials placed in or around the tumor. Correlation models are created with fifteen simultaneously measured external/internal marker position pairs divided over the respiratory cycle. Every 45-150 s, the correlation model is updated by replacing the three first acquired data pairs with three new pairs. Tracking simulations for &gt;120.000 computer-generated respiratory tracks demonstrated that this tracking approach resulted in relevant inaccuracies in internal target position predictions, especially in case of presence of respiratory motion baseline drifts. Approach. To better cope with drifts, we introduced a novel correlation model with an explicit time dependence, and we proposed to replace the currently applied linear-motion tracking (LMT) by mixed-model tracking (MMT). In MMT, the linear correlation model is extended with an explicit time dependence in case of a detected baseline drift. MMT prediction accuracies were then established for the same &gt;120.000 computer-generated patients as used for LMT. Main results. For 150 s update intervals, MMT outperformed LMT in internal target position prediction accuracy for 93.7 ∣ 97.2% of patients with 0.25 ∣ 0.5 mm min−1 linear respiratory motion baseline drifts with similar numbers of X-ray images and similar treatment times. For the upper 25% of patients, mean 3D internal target position prediction errors reduced by 0.7 ∣ 1.8 mm, while near maximum reductions (upper 10% of patients) were 0.9 ∣ 2.0 mm. Significance. For equal numbers of acquired X-ray images, MMT greatly improved tracking accuracy compared to LMT, especially in the presence of baseline drifts. Even with almost 50% less acquired X-ray images, MMT still outperformed LMT in internal target position prediction accuracy.</p

    The feasibility, safety and optimization of multiple prolonged breath-holds for radiotherapy.

    Get PDF
    BACKGROUND & PURPOSE Multiple, short breath-holds are now used in single radiotherapy treatment sessions. Here we investigated the feasibility and safety of multiple prolonged breath-holds in a single session. We measured how long is a second breath-hold if we prematurely terminate a single, prolonged breath-hold of >5 min either by using a single breath of oxygen (O), or by reintroducing preoxygenation and hypocapnia. We also investigated the feasibility and safety of undertaking 9 prolonged breath-holds in a row. MATERIALS & METHODS 30 healthy volunteers with no previous breath-holding experience were trained to perform single prolonged breath-holds safely. RESULTS Their mean single, prolonged breath-hold duration was 6.1 ± 0.3 se minutes (n = 30). In 18/18 subjects, premature termination (at 5.1 ± 0.2 min) with a single breath of 60% O, enabled a 2nd safe breath-hold lasting 3.3 ± 0.2 min. In 18/18 subjects, premature termination at 5.3 ± 0.2 min) by reintroducing preoxygenation and hypocapnia, enabled a 2nd safe breath-hold lasting 5.8 ± 0.3 min. 17/17 subjects could safely perform 9 successive prolonged breath-holds, each terminated (at 4.3 ± 0.2 min) by reintroducing preoxygenation and hypocapnia for 3.1 ± 0.2 min. The 9th unconstrained breath-hold (mean of 6.0 ± 0.3 min) lasted as long as their single breath-hold. CONCLUSIONS Multiple prolonged breath-holds are possible and safe. In a ∼19 min treatment session, it would therefore be possible to have ∼13 min for radiotherapy treatment (3 breath-holds) and ∼6 min for setup and recovery. In a 65 min session, it would be possible to have 41 min for radiotherapy and 25 min for setup and recovery

    Safely achieving single prolonged breath-holds of > 5 minutes for radiotherapy in the prone, front crawl position.

    No full text
    OBJECTIVE Breast cancer radiotherapy is increasingly delivered supine with multiple, short breath-holds. There may be heart and lung sparing advantages for locoregional breast cancer of both prone treatment and in a single breath-hold. We test here whether single prolonged breath-holds are possible in the prone, front crawl position. METHODS 19 healthy volunteers were trained to deliver supine, single prolonged breath-holds with pre-oxygenation and hypocapnia. We tested whether all could achieve the same durations in the prone, front crawl position. RESULTS 19 healthy volunteers achieved supine, single prolonged breath-holds for mean of 6.2 ± 0.3 min. All were able to hold safely for the same duration while prone (6.1 ± 0.2 min . by paired ANOVA). With prone, the increased weight on the chest did not impede chest inflation, nor the ability to hold air in the chest. Thus, the rate of chest deflation (mean anteroposterior deflation movement of three craniocaudally arranged surface markers on the spinal cord) was the same (1.2 ± 0.2, 2.0 ± 0.4 and 1.2 ± 0.4 mm/min) as found previously during supine prolonged breath-holds. No leakage of carbon dioxide or air was detectable into the facemask. CONCLUSION Single prolonged (>5 min) breath-holds are equally possible in the prone, front crawl position. ADVANCES IN KNOWLEDGE Prolonged breath-holds in the front crawl position are possible and have the same durations as in the supine position. Such training would therefore be feasible for some patients with breast cancer requiring loco-regional irradiation. It would have obvious advantages for hypofractionation
    • …