    Melatonin in Childhood Epilepsy and in Child Neurology

    Get PDF
    Melatonin (MLT) was isolated as a hormone by Lerner in 1958, and since then, intense studies have been under way with respect to its action and possibilities of application in various fields of medicine. Despite the existence of multiple antiepileptic medications and progress that has taken place in neurosurgical treatment of epilepsy, drug-resistant epilepsy continues to be a phenomenon that occurs in 30–35% children treated for epileptic seizures. Reports presented in the study have shown that children with epilepsy suffer from sleep disorders. Sleep deprivation may cause seizures, and on the other hand, an increased frequency of seizures may lead to sleep disturbances

    Design and development of a novel Invasive Blood Pressure simulator for patient's monitor testing

    Get PDF
    This paper presents a newly-designed and realized Invasive Blood Pressure (IBP) device for the simulation on patient’s monitors. This device shows improvements and presents extended features with respect to a first prototype presented by the authors and similar systems available in the state-of-the-art. A peculiarity of the presented device is that all implemented features can be customized from the developer and from the point of view of the end user. The realized device has been tested, and its performances in terms of accuracy and of the back-loop measurement of the output for the blood pressure regulation utilization have been described. In particular, an accuracy of ±1 mmHg at 25 °C, on a range from −30 to 300 mmHg, was evaluated under different test conditions. The designed device is an ideal tool for testing IBP modules, for zero setting, and for calibrations. The implemented extended features, like the generation of custom waveforms and the Universal Serial Bus (USB) connectivity, allow use of this device in a wide range of applications, from research to equipment maintenance in clinical environments to educational purposes. Moreover, the presented device represents an innovation, both in terms of technology and methodologies: It allows quick and efficient tests to verify the proper functioning of IBP module of patients’ monitors. With this innovative device, tests can be performed directly in the field and faster procedures can be implemented by the clinical maintenance personnel. This device is an open source project and all materials, hardware, and software are fully available for interested developers or researchers.Web of Science201art. no. 25

    A wavelet-based VCG QRS loop boundaries and isoelectric coordinates detector

    Get PDF
    This paper deals with a wavelet-based algorithm for automatic detection of isoelectric coordinates of individual QRS loops of VCG record. Fiducial time instants of QRS peak, QRS onset, QRS end, and isoelectric PQ interval are evaluated on three VCG leads (X, Y, Z) together with global QRS boundaries of a record to spatiotemporal QRS loops alignment. The algorithm was developed and optimized on 161 VCG records of PTB diagnostic database of healthy control subjects (HC), patients with myocardial infarction (MI) and patients with bundle branch block (BBB) and validated on CSE multilead measurement database of 124 records of the same diagnostic groups. The QRS peak was evaluated correctly for all of 1,467 beats. QRS onset, QRS end were detected with standard deviation of 5,5 ms and 7,8 ms respectively from the referee annotation. The isoelectric 20 ms length PQ interval window was detected correctly between the P end and QRS onset for all the cases. The proposed algorithm complies the (2 sigma(CSE)) limits for the QRS onset and QRS end detection and provides comparable or better results to other well-known algorithms. The algorithm evaluates well a wide QRS based on automated wavelet scale switching. The designed multi-lead approach QRS loop detector accomplishes diagnostic VCG processing, aligned QRS loops imaging and it is suitable for beat-to-beat variability assessment and further automatic VCG classification.Web of Science13art. no. 94182

    Circadian Profile of Salivary Melatonin Secretion in Hypoxic Ischemic Encephalopathy

    Get PDF
    Purpose. In the present study, the salivary melatonin secretion in the hypoxic ischemic encephalopathy (HIE) children was measured. The logit model was fitted to the data to obtain the salivary dim light melatonin onsets (DLMOs), and the results were compared with the values estimated from the classic threshold method with a linear interpolation and those previously published for the blood measurements. Materials and Methods. 9 patients suffering from HIE aged from 65 to 80 months were included in the study. The melatonin levels were assessed by a radioimmunoassay (RIA). The diurnal melatonin secretion was estimated using a nonlinear least squares method. Student’s t-test and the Mann–Whitney U test were used for the comparisons of the obtained parameters. Results. The circadian profiles of the melatonin secretion for both calculation methods do not differ statistically. The DLMO parameters obtained in the blood and saliva samples in children with hypoxic is chemic encephalopathy were similar

    Electronic invasive blood pressure simulator device for patient monitor testing

    No full text
    This work deal with design and realization of invasive blood pressure patient‘s side bad monitor testing by our original electronic device. Designed device enable to generate precise and wide range of pressure- voltage curve signal for using on any IBP monitors. User adaptive interface with display and control buttons makes it easy for use. The primary applications of these invasive blood pressure simulations are calibrating the patient’s monitors that are the general usages of the developed device. Ill. 9, bibl. 5, tabl. 3 (in English; abstracts in English and Lithuanian).Web of Science1196544

    Melatonin in Tuberous Sclerosis Complex Analysis Using Modern Mathematical Modeling Methods

    No full text
    Purpose. The aim of the study was to assess melatonin secretion pattern in children with TSC and to compare it with the secretion patterns in children with and without epilepsy. Material and Methods. Melatonin secretion was measured every three hours using the RIA method in four children with recognized TSC. The parameters of the melatonin secretion models were interpreted and compared with those obtained for the patients with epilepsy (n=76) and the children from the control, nonepileptic group (n=36). To describe the diurnal melatonin secretion, mathematical model was constructed and nonlinear least squares method with the Levenberg-Marquardt optimization algorithm was applied to approximate its parameters. The dim light melatonin onset (DLMO) parameters were also estimated from the model. Results and Conclusions. Statistically significant differences were found between the TSC melatonin secretion profiles and the nonepileptic control group. The profiles for the epileptic and TSC groups were found to be similar. For the TSC group, though a small one, the variations in the MLT release amplitudes seem to be independent of the total number of seizures; however, the MLT release shift appears to depend on the number of seizures

    Melatonin in Hypoxic-Ischemic Brain Injury in Term and Preterm Babies

    No full text
    Melatonin may serve as a potential therapeutic free radical scavenger and broad-spectrum antioxidant. It shows neuroprotective properties against hypoxic-ischemic brain injury in animal models. The authors review the studies focusing on the neuroprotective potential of melatonin and its possibility of treatment after perinatal asphyxia. Melatonin efficacy, low toxicity, and ability to readily cross through the blood-brain barrier make it a promising molecule. A very interesting thing is the difference between the half-life of melatonin in preterm neonates (15 hours) and adults (45-60 minutes). Probably, the use of synergic strategies—hypothermia coupled with melatonin treatment—may be promising in improving antioxidant action. The authors discuss and try to summarize the evidence surrounding the use of melatonin in hypoxic-ischemic events in term and preterm babies

    Melatonin in Epilepsy: A New Mathematical Model of Diurnal Secretion

    No full text
    Purpose. The main objective of the study was to create a mathematical model that describes the melatonin circadian secretion and, then the functionality of the model was tested by a comparison of the melatonin secretions in children with and without epilepsy. Material and Methods. The patients were divided into the epilepsy group (EG, n=52) and the comparison group (CG, n=30). The melatonin level was assessed by a radioimmunoassay method. The diurnal melatonin secretion was described using a nonlinear least squares method. Spearman’s rank correlation coefficient was chosen to estimate the dependence of the acquired data. The model reproduces blood concentration profiles and its parameters were statistically analyzed using the Mann-Whitney-Wilcoxon test and logistic regression. Results. The correlation analysis performed for the EG and CG groups showed moderate correlations between age and the melatonin secretion model parameters. Patients with epilepsy are characterized by an increased phase shift of melatonin release

    Present results and methods of vectorcardiographic diagnostics of ischemic heart disease

    No full text
    : This article presents an overview of existing approaches to perform vectorcardiographic (VCG) diagnostics of ischemic heart disease (IHD). Individual methodologies are divided into categories to create a comprehensive and clear overview of electrical cardiac activity measurement, signal pre-processing, features extraction and classification procedures. An emphasis is placed on methods describing the electrical heart space (EHS) by several features extraction techniques based on spatiotemporal characteristics or signal modelling and signal transformations. Performance of individual methodologies are compared depending on classification of extent of ischemia, acute forms - myocardial infarction (MI) and myocardial scars localization. Based on a comparison of imaging methods, the advantages of VCG over the standard 12-leads ECG such as providing a 3D orthogonal leads imaging, better performance, and appropriate computer processing are highlighted. The issues of electrical cardiac activity measurements on body surface, the lack of VKG databases supported by a more accurate imaging method, possibility of comparison with the physiology of individual cases are outlined as potential reserves for future research