1,476 research outputs found

    Exercises for word analysis in grade II.

    Full text link
    Thesis (Ed.M.)--Boston University N.B.: the following pages are missing: cover page; pages 374-376 at end of text

    A study of the stress wave factor technique for nondestructive evaluation of composite materials

    Get PDF
    The acousto-ultrasonic method of nondestructive evaluation is an extremely sensitive means of assessing material response. Efforts continue to complete the understanding of this method. In order to achieve the full sensitivity of the technique, extreme care must be taken in its performance. This report provides an update of the efforts to advance the understanding of this method and to increase its application to the nondestructive evaluation of composite materials. Included are descriptions of a novel optical system that is capable of measuring in-plane and out-of-plane displacements, an IBM PC-based data acquisition system, an extensive data analysis software package, the azimuthal variation of acousto-ultrasonic behavior in graphite/epoxy laminates, and preliminary examination of processing variation in graphite-aluminum tubes

    A study of the stress wave factor technique for evaluation of composite materials

    Get PDF
    The acousto-ultrasonic approach for nondestructive evaluation provides a measurement procedure for quantifying the integrated effect of globally distributed damage characteristic of fiber reinforced composite materials. The evaluation procedure provides a stress wave factor that correlates closely with several material performance parameters. The procedure was investigated for a variety of materials including advanced composites, hybrid structure bonds, adhesive bonds, wood products, and wire rope. The research program focused primarily on development of fundamental understanding and applications advancements of acousto-ultrasonics for materials characterization. This involves characterization of materials for which detection, location, and identification of imperfections cannot at present be analyzed satisfactorily with mechanical performance prediction models. In addition to presenting definitive studies on application potentials, the understanding of the acousto-ultrasonic method as applied to advanced composites is reviewed

    A physical model for the acousto-ultrasonic method

    Get PDF
    A basic physical explanation, a model, and comments on NDE application of the acousto-ultrasonic (AU) method for composite materials are presented. The basis of this work is a set of experiments where a sending and a receiving piezoelectric transducer were both oriented normal to the surface, at different points, on aluminum plates, various composite plates, and a tapered aluminum plate. The purpose and basic idea is introduced. Also, general comments on the AU method are offered. A literature review is offered for areas pertinent, such as composite materials, wave propagation, ultrasonics, and the AU. Special emphasis is given to theory which is used later on and past experimental results that are important to the physical understanding of the AU method. The experimental set-up, procedure, and the ensuing analysis are described. The experimental results are presented in both a quantitative and qualitative manner. A physical understanding of experimental results based on elasticity solution is furnished. Modeling and applications of the AU method is discussed for composite material and general conclusions are stated. The physical model of the AU method for composite materials is offered, something which has been much needed and sorely lacking. This physical understanding is possible due to the extensive set of experimental measurements, also reported

    Non invasive prenatal diagnosis of aneuploidy: next generation sequencing or fetal DNA enrichment?

    Get PDF
    Current invasive procedures [amniocentesis and chorionic villus sampling (CVS)] pose a risk to mother and fetus and such diagnostic procedures are available only to high risk pregnancies limiting aneuploidy detection rate. This review seeks to highlight the necessity of investing in non invasive prenatal diagnosis (NIPD) and how NIPD would improve patient safety and detection rate as well as allowing detection earlier in pregnancy. Non invasive prenatal diagnosis can take either a proteomics approach or nucleic acid-based approach; this review focuses on the latter. Since the discovery of cell free fetal DNA (cffDNA) and fetal RNA in maternal plasma, procedures have been developed for detection for monogenic traits and for some have become well established (e.g., RHD blood group status). However, NIPD of aneuploidies remains technically challenging. This review examines currently published literature evaluating techniques and approaches that have been suggested and developed for aneuploidy detection, highlighting their advantages and limitations and areas for further research

    Exploring Human Response Times to Combinations of Audio, Haptic, and Visual Stimuli from a Mobile Device

    Full text link
    Auditory, haptic, and visual stimuli provide alerts, notifications, and information for a wide variety of applications ranging from virtual reality to wearable and hand-held devices. Response times to these stimuli have been used to assess motor control and design human-computer interaction systems. In this study, we investigate human response times to 26 combinations of auditory, haptic, and visual stimuli at three levels (high, low, and off). We developed an iOS app that presents these stimuli in random intervals and records response times on an iPhone 11. We conducted a user study with 20 participants and found that response time decreased with more types and higher levels of stimuli. The low visual condition had the slowest mean response time (mean +/- standard deviation, 528 +/- 105 ms) and the condition with high levels of audio, haptic, and visual stimuli had the fastest mean response time (320 +/- 43 ms). This work quantifies response times to multi-modal stimuli, identifies interactions between different stimuli types and levels, and introduces an app-based method that can be widely distributed to measure response time. Understanding preferences and response times for stimuli can provide insight into designing devices for human-machine interaction.Comment: Accepted to World Haptics Conference 202

    Dielectronic Recombination of Ground-State and Metastable Li+ Ions

    Get PDF
    Dielectronic recombination has been investigated for Delta-n = 1 resonances of ground-state Li+(1s^2) and for Delta-n = 0 resonances of metastable Li+(1s2s ^3S). The ground-state spectrum shows three prominent transitions between 53 and 64 eV, while the metastable spectrum exhibits many transitions with energies < 3.2 eV. Reasonably good agreement of R-matrix, LS coupling calculations with the measured recombination rate coefficient is obtained. The time dependence of the recombination rate yields a radiative lifetime of 52.2 +- 5.0 s for the 2 ^3S level of Li+.Comment: Submitted to Phys. Rev. A; REVTeX, 4 pages, 3 figure

    Dose Effects of Oxaliplatin on Persistent and Transient Na+ Conductances and the Development of Neurotoxicity

    Get PDF
    BACKGROUND: Oxaliplatin, a platinum-based chemotherapy utilised in the treatment of colorectal cancer, produces two forms of neurotoxicity--acute sensorimotor neuropathic symptoms and a dose-limiting chronic sensory neuropathy. Given that a Na(+) channelopathy has been proposed as the mechanism underlying acute oxaliplatin-induced neuropathy, the present study aimed to determine specific mechanisms of Na(+) channel dysfunction. METHODOLOGY/PRINCIPAL FINDINGS: Specifically the function of transient and persistent Na(+) currents were followed during treatment and were investigated in relation to oxaliplatin dose level. Eighteen patients were assessed before and after a single oxaliplatin infusion with motor and sensory axonal excitability studies performed on the median nerve at the wrist. While refractoriness (associated with Na(+) channel inactivation) was significantly altered post-oxaliplatin infusion in both motor (Pre: 31.7±6.4%; Post: 68.8±14.5%; P≤.001) and sensory axons (Pre: 31.4±5.4%; Post: 21.4±5.5%; P<.05), strength-duration time constant (marker of persistent Na(+) conductances) was not significantly altered post-infusion (Motor Pre: 0.395±0.01 ms; Post: 0.394±0.02 ms; NS; Sensory Pre:0.544±0.03 ms; Post: 0.535±0.05 ms; NS). However, changes in strength-duration time constant were significantly correlated with changes in refractoriness in motor and sensory axons (Motor correlation coefficient = -.65; P<.05; Sensory correlation coefficient = .67; P<.05). CONCLUSIONS/SIGNIFICANCE: It is concluded that the predominant effect of acute oxaliplatin exposure in human motor and sensory axons is mediated through changes in transient rather than persistent Na(+) conductances. These findings are likely to have implications for the design and trial of neuroprotective strategies

    Photoelectron spectroscopy measurements and theoretical calculations of the lowest doubly hollow lithium state

    Get PDF
    We have measured, using electron spectroscopy, the lowest-energy doubly hollow lithium triply excited (3l3l′3l″) 2P state. Energies, widths, and partial cross sections have been measured and calculated using the saddle-point technique and the R-matrix approximation. Our results show good agreement between experimental and theoretical data for the energy and the width of the doubly hollow state
    corecore