4 research outputs found

    Long‐term indoor gunshot exposure of special police forces induces bronchitic reactions and elevated blood lead levels—The Berlin shooting range study

    Get PDF
    Background Gunshot emissions contain toxic elements that can harm those frequently exposed, such as police officers. Several years ago, police indoor firing ranges were closed by the Berlin municipality in response to police officer health complaints, and an investigation was launched into the possible respiratory health risks of frequent gunshot emission exposure. We, therefore, conducted an exploratory cross-sectional study to investigate clinical and functional parameters of respiratory health as well as the burden of trace elements in policemen with long-term high exposure to indoor gunshot emissions, compared to low-exposure and control groups. Methods We conducted lung function tests and collected blood and urine samples from Berlin police officers and government employees who were divided into three subject groups based on exposure to gunshot emissions: high exposure (n = 53), low exposure (n = 94) and no exposure (n = 76). Lung function was examined using body plethysmography. Blood and urine samples were tested via inductively coupled plasma mass spectrometry for the presence of common gunshot powder elements (antimony, lead and manganese). Exposure and symptoms were assessed using records as well as questionnaires. Results Higher exposure was associated with more respiratory symptoms during gun shooting practice (64% vs. 21%, P < 0.001) compared to the low-exposure group. Headache, cough, discoloured mucous and shortness of breath were also more common as were some other symptoms. The cough symptomatology of the high-exposure group also persisted significantly longer (median: 0.67 vs. 0.01 days, range: 0 to 5 days, P = 0.029) compared to the low-exposure group. They also showed a lower forced expiratory volume in 1 s/forced vital capacity quotient (Tiffeneau index), P = 0.018 between the three groups and P = 0.005 for the high-exposure group, a possible marker of early, subclinical bronchial obstruction. We observed increased blood lead concentrations depending on subject's age (+1.2% per year, 95% confidence interval: 0.5–1.9%, P < 0.001) and cumulative gunshot exposure (+0.34% per 100 000 shots, 0.02–0.66%, P = 0.037). Conclusions These first results suggest that long-term exposure to indoor gunshot emissions induces bronchitic reactions due to repeated irritation of the airways. Higher levels of exposure lead to more negatively impacted lung function and higher blood lead levels with the possible reason that more frequent exposure may mean shorter regeneration phases for the respiratory mucous membrane. We recommend a reduction of exposure to gunshot emissions in order to decrease symptoms and avoid any—even small—deterioration in spirometry

    Measuring Core Body Temperature Using a Non-invasive, Disposable Double-Sensor During Targeted Temperature Management in Post-cardiac Arrest Patients

    Get PDF
    Background: Precisely measuring the core body temperature during targeted temperature management after return of spontaneous circulation is mandatory, as deviations from the recommended temperature might result in side effects such as electrolyte imbalances or infections. However, previous methods are invasive and lack easy handling. A disposable, non-invasive temperature sensor using the heat flux approach (Double Sensor), was tested against the standard method: an esophagus thermometer. Methods: The sensor was placed on the forehead of adult patients (n = 25, M/F, median age 61 years) with return of spontaneous circulation after cardiac arrest undergoing targeted temperature management. The recorded temperatures were compared to the established measurement method of an esophageal thermometer. A paired t-test was performed to examine differences between methods. A Bland-Altman-Plot and the intraclass correlation coefficient were used to assess agreement and reliability. To rule out possible influence on measurements, the patients' medication was recorded as well. Results: Over the span of 1 year and 3 months, data from 25 patients were recorded. The t-test showed no significant difference between the two measuring methods (t = 1.47, p = 0.14, n = 1,319). Bland-Altman results showed a mean bias of 0.02 degrees C (95% confidence interval 0.00-0.04) and 95% limits of agreement of -1.023 degrees C and 1.066 degrees C. The intraclass correlation coefficient was 0.94. No skin irritation or allergic reaction was observed where the sensor was placed. In six patients the bias differed noticeably from the rest of the participants, but no sex-based or ethnicity-based differences could be identified. Influences on the measurements of the Double Sensor by drugs administered could also be ruled out. Conclusions: This study could demonstrate that measuring the core body temperature with the non-invasive, disposable sensor shows excellent reliability during targeted temperature management after survived cardiac arrest. Nonetheless, clinical research concerning the implementation of the sensor in other fields of application should be supported, as well as verifying our results by a larger patient cohort to possibly improve the limits of agreement

    Tapering Canakinumab Monotherapy in Patients with Systemic Juvenile Idiopathic Arthritis in Clinical Remission: Results from an Open\u2010label, Randomized Phase IIIb/IV Study

    No full text

    Proceedings of the 23rd Paediatric Rheumatology European Society Congress: part one

    No full text
    corecore