58 research outputs found

    Community-Based Risk Assessment for Humanitarian Mine Action : A Case Study of Cambodia

    Get PDF

    The Hobbesian Absolute Value : An Analysis of the Middle Ground

    Get PDF

    Acute intervention during myocardial infarction in patients with prior coronary bypass surgery

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/28662/1/0000479.pd

    The effect of different mechanisms of myocardial ischemia on left ventricular function

    Full text link
    Myocardial ischemia may be produced by limitation of blood flow as in abrupt coronary occlusion, termed supply-type ischemia, or by increasing myocardial oxygen demand in the setting of restricted flow, termed demand-type ischemia. To examine the comparative extent and severity of the dysfunction related to both forms of ischemia, we studied anesthetized, open-chest dogs by means of two-dimensional echocardiography and tracer microspheres. Supply-type ischemia was produced by total occlusion of the LCx (n = 7); demand-type ischemia was induced by infusion of dobutamine after creation of a critical LCx stenosis (n = 6). At the time of the production of ischemia, the group with demand-type ischemia had significant increases in both heart rate (p p p p p p < 0.05). Thus these data suggest that supply-type ischemia produced by coronary occlusion results in a greater extent and degree of left ventricular functional abnormality than pharmacologically induced demand-type ischemia.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/27575/1/0000619.pd

    Planning and delivery of intensity modulated bolus electron conformal therapy

    Get PDF
    PURPOSE: Bolus electron conformal therapy (BECT) is a clinically useful, well-documented, and available technology. The addition of intensity modulation (IM) to BECT reduces volumes of high dose and dose spread in the planning target volume (PTV). This paper demonstrates new techniques for a process that should be suitable for planning and delivering IM-BECT using passive radiotherapy intensity modulation for electrons (PRIME) devices. METHODS: The IM-BECT planning and delivery process is an addition to the BECT process that includes intensity modulator design, fabrication, and quality assurance. The intensity modulator (PRIME device) is a hexagonal matrix of small island blocks (tungsten pins of varying diameter) placed inside the patient beam-defining collimator (cutout). Its design process determines a desirable intensity-modulated electron beam during the planning process, then determines the island block configuration to deliver that intensity distribution (segmentation). The intensity modulator is fabricated and quality assurance performed at the factory (.decimal, LLC, Sanford, FL). Clinical quality assurance consists of measuring a fluence distribution in a plane perpendicular to the beam in a water or water-equivalent phantom. This IM-BECT process is described and demonstrated for two sites, postmastectomy chest wall and temple. Dose plans, intensity distributions, fabricated intensity modulators, and quality assurance results are presented. RESULTS: IM-BECT plans showed improved D CONCLUSION: These results demonstrated the feasibility of translating IM-BECT to the clinic using the techniques presented for treatment planning, intensity modulator design and fabrication, and quality assurance processes

    Effect of afterload alterations on the functional border zone measured with two-dimensional echocardiography during acute coronary occlusion

    Full text link
    In the setting of acute myocardial infarction, pharmacologic intervention resulting in afterload changes are common but the effect of these changes on regional left ventricular function, and specifically the functional border zone, has not been fully investigated. Accordingly, we studied the effects of afterload manipulation on circumferential flow-function relationships and the functional border zone in 16 open-chest, anesthetized dogs. During left circumflex coronary artery occlusion, eight animals were infused with phenylephrine to increase afterload; eight others received nitroprusside for afterload reduction. Following coronary artery occlusion, subendocardial blood flow and wall thickening decreased in the ischemic zone (p p = ns). Similarly, when blood pressure was increased by 47%, the extent of the functional border zone did not change (32 +/- 10 degrees vs 37 +/- 10 degrees). Therefore circumferential flow-function relations and the spatial extent of the functional border zone are not altered by changing afterload during acute left circumflex coronary artery occlusion in this model.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/27132/1/0000125.pd

    Single mutation to a sex pheromone receptor provides adaptive specificity between closely related moth species

    Get PDF
    Sex pheromone communication, acting as a prezygotic barrier to mating, is believed to have contributed to the speciation of moths and butterflies in the order Lepidoptera. Five decades after the discovery of the first moth sex pheromone, little is known about the molecular mechanisms that underlie the evolution of pheromone communication between closely related species. Although Asian and European corn borers (ACB and ECB) can be interbred in the laboratory, they are behaviorally isolated from mating naturally by their responses to subtly different sex pheromone isomers, (E)-12- and (Z)-12-tetradecenyl acetate and (E)-11- and (Z)-11-tetradecenyl acetate (ACB: E12, Z12; ECB; E11, Z11). Male moth olfactory systems respond specifically to the pheromone blend produced by their conspecific females. In vitro, ECB(Z) odorant receptor 3 (OR3), a sex pheromone receptor expressed in male antennae, responds strongly to E11 but also generally to the Z11, E12, and Z12 pheromones. In contrast, we show that ACB OR3, a gene that has been subjected to positive selection (ω = 2.9), responds preferentially to the ACB E12 and Z12 pheromones. In Ostrinia species the amino acid residue corresponding to position 148 in transmembrane domain 3 of OR3 is alanine (A), except for ACB OR3 that has a threonine (T) in this position. Mutation of this residue from A to T alters the pheromone recognition pattern by selectively reducing the E11 response ∼14-fold. These results suggest that discrete mutations that narrow the specificity of more broadly responsive sex pheromone receptors may provide a mechanism that contributes to speciation

    A randomized trial comparing digital and live lecture formats [ISRCTN40455708

    Get PDF
    BACKGROUND: Medical education is increasingly being conducted in community-based teaching sites at diverse locations, making it difficult to provide a consistent curriculum. We conducted a randomized trial to assess whether students who viewed digital lectures would perform as well on a measure of cognitive knowledge as students who viewed live lectures. Students' perceptions of the digital lecture format and their opinion as whether a digital lecture format could serve as an adequate replacement for live lectures was also assessed. METHODS: Students were randomized to either attend a lecture series at our main campus or view digital versions of the same lectures at community-based teaching sites. Both groups completed the same examination based on the lectures, and the group viewing the digital lectures completed a feedback form on the digital format. RESULTS: There were no differences in performance as measured by means or average rank. Despite technical problems, the students who viewed the digital lectures overwhelmingly felt the digital lectures could replace live lectures. CONCLUSIONS: This study provides preliminary evidence digital lectures can be a viable alternative to live lectures as a means of delivering didactic presentations in a community-based setting

    The implementation of a mobile problem-specific electronic CEX for assessing directly observed student—patient encounters

    Get PDF
    Background: Facilitating direct observation of medical students' clinical competencies is a pressing need. Methods: We developed an electronic problem-specific Clinical Evaluation Exercise (eCEX) based on a national curriculum. We assessed its feasibility in monitoring and recording students' competencies and the impact of a grading incentive on the frequency of direct observations in an internal medicine clerkship. Students (n=56) at three clinical sites used the eCEX and comparison students (n=56) at three other clinical sites did not. Students in the eCEX group were required to arrange 10 evaluations with faculty preceptors. Students in the second group were required to document a single, faculty observed ‘Full History and Physical’ encounter with a patient. Students and preceptors were surveyed at the end of each rotation. Results: eCEX increased students' and evaluators' understanding of direct-observation objectives and had a positive impact on the evaluators' ability to provide feedback and assessments. The grading incentive increased the number of times a student reported direct observation by a resident preceptor. Conclusions: eCEX appears to be an effective means of enhancing student evaluation

    Effects of video frame averaging, smoothing and edge enhancement on the accuracy and precision of quantitative coronary arteriography

    Full text link
    Digital analysis of cine film provides numerous options for altering images by frame averaging or filtering algorithms that either smooth or enhance edges. While these may subjectively enhance image quality, there is no uniformity in their use among laboratories and effects on quantitative coronary analysis may not be ideal. To determine which processing algorithms might help or hinder quantitative coronary arteriography, cine film images of precision drilled stenotic cylinders (0.83 to 1.83 mm diameter) implanted in dog coronary arteries were analyzed with and without such algorithms. Video frame averaging of 1 to 49 frames had no effect on measures of accuracy (mean differences) but precision (standard deviation of mean differences) was improved from 0.23 to 0.17 mm (p<0.05) with video averaging of ≥25 frames. Edge enhancement filtering algorithms resulted in slight deterioration of accuracy and precision and smoothing filtering algorithms caused modest improvements in these parameters; however, these changes were not significantly different from unprocessed images. Using edge enhancement filtering algorithms, accuracy was significantly worse (−0.27 mm) compared to a smoothing filter enhancement algorithm (−0.08 mm, p<0.001). The combination of video averaging and smoothing algorithms had no additional beneficial effects. Thus, precision of quantitative coronary analysis of cine film can be optimized by appropriate video averaging. Edge enhancement filtering algorithms should be avoided whereas smoothing filter enhancement algorithms may improve accuracy.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42544/1/10554_2005_Article_BF01797840.pd
    • …
    corecore