139 research outputs found

    Micro-scale blood plasma separation: from acoustophoresis to egg-beaters

    Get PDF

    Design, test and biological validation of microfluidic systems for blood plasma separation

    Get PDF
    Sample preparation has been described as the weak link in microfluidics. In particular, plasma has to be extracted from whole blood for many analysis including protein analysis, cell-free DNA detection for prenatal diagnosis and transplant monitoring. The lack of suitable devices to perform the separation at the microscale means that Lab On Chip (LOC) modules cannot be fully operated without sample preparation in a full-scale laboratory. In order to address this issue, blood flow in microchannels has been studied, and red blood cells behaviours in different geometrical environments have been classified. Several designs have been subsequently proposed to exploit some natural properties of blood flow and extract pure plasma without disturbing the cells. Furthermore, a high-level modelling method was developed to predict the behaviour of passive microfluidic networks. Additionally, the technique proposed provides useful guidance over the use of systems in more complex external environments. Experimental results have shown that plasma could be separated from undiluted whole blood in 10μm width microchannels at a flow rate of 2mL/hr. Using slightly larger structures (20μm) suitable for mass-manufacturing, diluted blood can be separated with 100% purity efficiency at high flow rate. An extensive biological validation of the extracted plasma was carried out to demonstrate its quality. To this effect Polymerase Chain Reaction (PCR) was performed to amplify targeted human genomic sequence from cell-free DNA present in the plasma. Furthermore, the influence of the sample dilution and separation efficiency on the amplification was characterised. It was shown that the sample dilution does have an influence on the amplification of house-keeping gene, but that amplification can be achieved even on high diluted samples. Additionally amplification can also be obtained on plasma samples with a range of separation efficiencies from 100% to 84%. In particular, two main points have been demonstrated (i) the extraction of plasma using combination of constrictions and bifurcations, (ii) the biological validation of the extracted plasma

    Parametrical modeling and design optimization of blood plasma separation device with microchannel mechanism

    Get PDF
    This paper presents an analysis of biofluid behavior in a T-shaped microchannel device and a design optimization for improved biofluid performance in terms of particle liquid separation. The biofluid is modeled with single phase shear rate non-Newtonian flow with blood property. The separation of red blood cell from plasma is evident based on biofluid distribution in the microchannels against various relevant effects and findings, including Zweifach-Fung bifurcation law, Fahraeus effect, Fahraeus-Lindqvist effect and cell free phenomenon. The modeling with the initial device shows that this T-microchannel device can separate red blood cell from plasma but the separation efficiency among different bifurcations varies largely. In accordance with the imbalanced performance, a design optimization is conducted. This includes implementing a series of simulations to investigate the effect of the lengths of the main and branch channels to biofluid behavior and searching an improved design with optimal separation performance. It is found that changing relative lengths of branch channels is effective to both uniformity of flow rate ratio among bifurcations and reduction of difference of the flow velocities between the branch channels, whereas extending the length of the main channel from bifurcation region is only effective for uniformity of flow rate ratio

    From equitable access to equitable innovation:Rethinking bioengineering for global health

    Get PDF
    What does global health equity mean? In bioengineering, ‘equity’ is often interpreted as global ‘access’ to technologies, thereby neglecting wider structural inequalities. Here we suggest that the concepts of equity need to be expanded to incorporate principles of equitable representation and recognition within the innovation ecosystem

    Effect of fluid dynamics and device mechanism on biofluid behaviour in microchannel systems: modelling biofluids in a microchannel biochip separator

    Get PDF
    Biofluid behaviour in microchannel systems is investigated in this paper through the modelling of a microfluidic biochip developed for the separation of blood plasma. Based on particular assumptions, the effects of some mechanical features of the microchannels on behaviour of the biofluid are explored. These include microchannel, constriction, bending channel, bifurcation as well as channel length ratio between the main and side channels. The key characteristics and effects of the microfluidic dynamics are discussed in terms of separation efficiency of the red blood cells with respect to the rest of the medium. The effects include the Fahraeus and Fahraeus-Lindqvist effects, the Zweifach-Fung bifurcation law, the cell-free layer phenomenon. The characteristics of the microfluid dynamics include the properties of the laminar flow as well as particle lateral or spinning trajectories. In this paper the fluid is modelled as a single-phase flow assuming either Newtonian or Non-Newtonian behaviours to investigate the effect of the viscosity on flow and separation efficiency. It is found that, for a flow rate controlled Newtonian flow system, viscosity and outlet pressure have little effect on velocity distribution. When the fluid is assumed to be Non-Newtonian more fluid is separated than observed in the Newtonian case, leading to reduction of the flow rate ratio between the main and side channels as well as the system pressure as a whole

    Versatile hybrid acoustic micromixer with demonstration of circulating cell-free DNA extraction from sub-ml plasma samples

    Get PDF
    A low-cost and easy to implement acoustic micromixer compatible with multiple fabrication technologies that can provide efficient and vigorous mixing
    • …
    corecore