504 research outputs found

    Side Differences of Thigh Muscle Cross-Sectional Areas and Maximal Isometric Muscle Force in Bilateral Knees with the Same Radiographic Disease Stage, but Unilateral Frequent Pain – Data from the Osteoarthritis Initiative

    Get PDF
    Objective To determine whether anatomical thigh muscle cross-sectional areas (MCSAs) and strength differ between osteoarthritis (OA) knees with frequent pain compared with contra-lateral knees without pain, and to examine the correlation between MCSAs and strength in painful vs painless knees. Methods Forty-eight subjects (31 women; 17 men; age 45–78 years) were drawn from 4,796 Osteoarthritis Initiative (OAI) participants, in whom both knees displayed the same radiographic stage (KLG2 or 3), one with frequent pain (most days of the month within the past 12 months) and the contra-lateral one without pain. Axial MR images were used to determine MCSAs of extensors, flexors and adductors at 35% femoral length (distal to proximal) and in two adjacent 5 mm images. Maximal isometric extensor and flexor forces were used as provided from the OAI database. Results Painful knees showed 5.2% lower extensor MCSAs (P = 0.00003; paired t-test), and 7.8% lower maximal extensor muscle forces (P = 0.003) than contra-lateral painless knees. There were no significant differences in flexor forces, or flexor and adductor MCSAs (P > 0.39). Correlations between force and MCSAs were similar in painful and painless OA knees (0.44 < r < 0.66). Conclusions Knees with frequent pain demonstrate lower MCSAs and force of the quadriceps (but not of other thigh muscles) compared with contra-lateral knees without knee pain with the same radiographic stage. Frequent pain does not appear to affect the correlations between MCSAs and strength in OA knees. The findings suggest that quadriceps strengthening exercise may be useful in treating symptomatic knee OA

    Large non-thermal contribution to picosecond strain pulse generation using the photo-induced phase transition in VO2

    Get PDF
    Picosecond strain pulses are a versatile tool for investigation of mechanical properties of meso-and nano-scale objects with high temporal and spatial resolutions. Generation of such pulses is traditionally realized via ultrafast laser excitation of a light-to-strain transducer involving thermoelastic, deformation potential, or inverse piezoelectric effects. These approaches unavoidably lead to heat dissipation and a temperature rise, which can modify delicate specimens, like biological tissues, and ultimately destroy the transducer itself limiting the amplitude of generated picosecond strain. Here we propose a novel non-thermal mechanism for generating picosecond strain pulses via ultrafast photo-induced first-order phase transitions (PIPTs). We perform experiments on vanadium dioxide VO2 films, which exhibit a first-order PIPT accompanied by a lattice change. We demonstrate that during femtosecond optical excitation of VO2 the PIPT alone contributes to ultrafast expansion of this material as large as 0.45%, which is not accompanied by heat dissipation, and, for excitation density of 8 mJ cm-2 , exceeds the contribution from thermoelastic effect by the factor of five.

    Comparison of debulking followed by stenting versus stenting alone for saphenous vein graft aortoostial lesions: immediate and one-year clinical outcomes

    Get PDF
    AbstractOBJECTIVESWe compared in-hospital and one-year clinical outcomes in patients undergoing debulking followed by stent implantation versus stenting alone for saphenous vein graft (SVG) aortoostial lesions.BACKGROUNDStent implantation in SVG aortoostial lesions may improve procedural and late clinical outcomes. However, the impact of debulking before stenting in this complex lesion subset is unknown.METHODSWe studied 320 consecutive patients (340 SVG aortoostial lesions) treated with Palmaz-Schatz stents. Debulking with excimer laser or atherectomy was performed in 133 patients (139 lesions) before stenting (group I), while 187 patients (201 lesions) underwent stent implantation without debulking (group II). Procedural success and late clinical outcomes were compared between the groups.RESULTSOverall procedural success (97.6%) was similar between the groups. Procedural complications were also similar (2.2% for group I and 2.6% for group II). At one-year follow-up, target lesion revascularization (TLR) was 19.4% for group I and 18.2% for group II (p = 0.47). There was no difference in cumulative death or Q wave myocardial infarction between the groups. Overall cardiac event-free survival was similar (69% for group I and 68% for group II). By Cox regression analysis, the independent predictors of late cardiac events were final lumen cross-sectional area (CSA) by intravascular ultrasound (IVUS) (p = 0.001) and restenotic lesions (p = 0.01). Similarly, final IVUS lumen CSA (p = 0.0001) and restenotic lesions (p = 0.006) were found to predict TLR at one year.CONCLUSIONSThese results suggest that, in most patients with SVG aortoostial lesions, debulking before stent implantation may not be necessary

    Improving and Assessing Planet Sensitivity of the GPI Exoplanet Survey with a Forward Model Matched Filter

    Full text link
    We present a new matched filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar Point Spread Function (PSF) is first subtracted using a Karhunen-Lo\'eve Image Processing (KLIP) algorithm with Angular and Spectral Differential Imaging (ADI and SDI). The KLIP-induced distortion of the astrophysical signal is included in the matched filter template by computing a forward model of the PSF at every position in the image. To optimize the performance of the algorithm, we conduct extensive planet injection and recovery tests and tune the exoplanet spectra template and KLIP reduction aggressiveness to maximize the Signal-to-Noise Ratio (SNR) of the recovered planets. We show that only two spectral templates are necessary to recover any young Jovian exoplanets with minimal SNR loss. We also developed a complete pipeline for the automated detection of point source candidates, the calculation of Receiver Operating Characteristics (ROC), false positives based contrast curves, and completeness contours. We process in a uniform manner more than 330 datasets from the Gemini Planet Imager Exoplanet Survey (GPIES) and assess GPI typical sensitivity as a function of the star and the hypothetical companion spectral type. This work allows for the first time a comparison of different detection algorithms at a survey scale accounting for both planet completeness and false positive rate. We show that the new forward model matched filter allows the detection of 50%50\% fainter objects than a conventional cross-correlation technique with a Gaussian PSF template for the same false positive rate.Comment: ApJ accepte

    Dynamical Mass Measurement of the Young Spectroscopic Binary V343 Normae AaAb Resolved With the Gemini Planet Imager

    Full text link
    We present new spatially resolved astrometry and photometry from the Gemini Planet Imager of the inner binary of the young multiple star system V343 Normae, which is a member of the beta Pictoris moving group. V343 Normae comprises a K0 and mid-M star in a ~4.5 year orbit (AaAb) and a wide 10" M5 companion (B). By combining these data with archival astrometry and radial velocities we fit the orbit and measure individual masses for both components of M_Aa = 1.10 +/- 0.10 M_sun and M_Ab = 0.290 +/- 0.018 M_sun. Comparing to theoretical isochrones, we find good agreement for the measured masses and JHK band magnitudes of the two components consistent with the age of the beta Pic moving group. We derive a model-dependent age for the beta Pic moving group of 26 +/- 3 Myr by combining our results for V343 Normae with literature measurements for GJ 3305, which is another group member with resolved binary components and dynamical masses.Comment: 12 pages, 7 figures. Accepted to A

    A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument

    Get PDF
    We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical bearings relatively small but allows for a large (305 mm) diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows for precise positioning and prevents undesired rotation when the motors are depowered. A custom-built optical encoder system monitors the bearing angle to an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider during its successful 16 day flight.Comment: 11 pages, 7 figures, Published in Review of Scientific Instruments. v2 includes reviewer changes and longer literature revie

    GPI spectra of HR 8799 c, d, and e from 1.5 to 2.4μ\mum with KLIP Forward Modeling

    Full text link
    We explore KLIP forward modeling spectral extraction on Gemini Planet Imager coronagraphic data of HR 8799, using PyKLIP and show algorithm stability with varying KLIP parameters. We report new and re-reduced spectrophotometry of HR 8799 c, d, and e in H & K bands. We discuss a strategy for choosing optimal KLIP PSF subtraction parameters by injecting simulated sources and recovering them over a range of parameters. The K1/K2 spectra for HR 8799 c and d are similar to previously published results from the same dataset. We also present a K band spectrum of HR 8799 e for the first time and show that our H-band spectra agree well with previously published spectra from the VLT/SPHERE instrument. We show that HR 8799 c and d show significant differences in their H & K spectra, but do not find any conclusive differences between d and e or c and e, likely due to large error bars in the recovered spectrum of e. Compared to M, L, and T-type field brown dwarfs, all three planets are most consistent with mid and late L spectral types. All objects are consistent with low gravity but a lack of standard spectra for low gravity limit the ability to fit the best spectral type. We discuss how dedicated modeling efforts can better fit HR 8799 planets' near-IR flux and discuss how differences between the properties of these planets can be further explored.Comment: Accepted to AJ, 25 pages, 16 Figure
    • …
    corecore