741 research outputs found
Modeling line-driven disk wind for broad absorption lines of quasars
The disk wind, which is powered by the radiation force due to spectral lines
(line force), is studied for broad absorption line (BAL) quasars. We
investigate the structure of the disk wind based on the non-hydrodynamic method
and compare with wind properties inferred from X-ray observations of BAL
quasars. In this paper, we apply the stellar wind theory to the initial
condition (the mass outflow rate at the base of the wind). We found the
funnel-shaped winds with a half opening angle of 50^{circ} for the case of
epsilon=0.3-0.9 and M_{BH}=10^{7-8.5}M_odot, where epsilon is the Eddington
ratio and M_{BH} is the black hole mass. Thus, the absorption features are
observed for an observer of which a viewing angle is around 50^{circ}. A
probability of BAL quasars is 7-11%, which is roughly consistent the abundance
ratio of BAL quasars, 10-15%. Here, the probability is estimated by the solid
angle, that the absorbing features would be detected, divided by 4pi. In
contrast, if the Eddington ratio is smaller than 0.01 or if the black hole is
very massive, M_{BH} < 10^9M_{odot}, the disk wind is not launched due to the
less effective line force. Then, the quasars are identified as non-BAL quasars
independently of the observer's viewing angle.Comment: 10 pages, 6 figures. Accepted for publication in PAS
Noise suppression using optimum filtering of OCs generated by a multiport encoder/decoder
We propose a novel receiver configuration using an extreme narrow band-optical band pass filter (ENB-OBPF) to reduce the multiple access interference (MAI) and beat noises in an optical code division multiplexing (OCDM) transmission. We numerically and experimentally demonstrate an enhancement of the code detectability, that allows us to increase the number of users in a passive optical network (PON) from 4 to 8 without any forward error correction (FEC)
Index of Donor Performance (2006 Edition): Selectivity and Project Proliferation Reconsidered
In this paper, we take up the Index of Donor Performance (IDP) constructed by the Center for Global Development (CGD), especially, discussing issues of selectivity and project proliferation in the IDP index. We argue theoretical issues of the Index from the aspect of the aid data characteristics.
Analysis of velocity profiles of blood flow in microchannels using confocal micro-PIV and particle method
The combination of computational and experimental investigations provides an
excellent approach to understand complex phenomena involved at a microscopic level. This
paper emphasizes a new experimental technique capable to quantify the flow patterns inside
microchannels with high spatial and temporal resolution. This technique, known as confocal
micro-PIV, consists of a spinning disk confocal microscope, high speed camera and a diodepumped
solid state (DPSS) laser. Velocity profiles of physiological fluids were measured
within different microchannels. The measured results agree reasonably well with the
predicted analytical values. This new PIV system is a very promising technique to confirm the
validity of the data obtained by numerical simulations, such as the MPS particle method
Os métodos computacionais em hemodinâmica
Até à última década do século XX, a investigação realizada em hemodinâmica limitava-se, essencialmente, a
estudos baseados em métodos experimentais e modelos matemáticos. No entanto, no final do século XX, os avanços
tecnológicos na área da computação e o custo mais baixo de aquisição propiciaram uma nova forma de investigar os
factores hemodinâmicos em termos fisiológicos e patológicos. Tal como tem acontecido em diversas áreas da ciência,
os métodos computacionais constituem um complemento bastante promissor para investigar e analisar uma série de
mecanismos fisiológicos e patológicos existentes nos vários órgãos do corpo humano. Este artigo trata, portanto, dos
métodos computacionais em hemodinâmica e faz uma breve descrição do processo e da aplicação destes métodos no
estudo do escoamento sanguÃne
Confocal micro-PIV measurements of blood flow in microchannels
The detail measurements of velocity profiles of blood flow in microchannels
are fundamental for a better understanding on the biomechanics of the
microcirculation. It is therefore very important to obtain measurements with
high accuracy and spatial resolution of the influence of the blood cells on
the plasma flow behaviour. This paper presents and compares measurements
of in vitro blood with different hematocrits within a square microchannel
obtained by a confocal particle image velocimetry (PIV) system. This emerging
technology by combining the conventional PIV system with a spinning confocal
microscope has the ability to obtain not only high spatial resolution images but
also three-dimensional (3D) optical sectioning velocity measurements. Velocity
measurements of plasma seeded with 1 ~tm diameter fluorescent particles were
performed at different locations along the depth of 100 ~tm square microchannel
at a constant flow rate (0.15~tl/min) and Reynolds number (Re) of 0.025. By
using our confocal micro-PIV system, it was possible to obtain time-series of
instantaneous velocity profiles with high spatial resolution of 28.24 18.83 ~tm
at time intervals of 5 ms between two images. The ensemble-averaged velocity
results of blood flow with different hematocrits (up to 25%) have shown velocity
profiles very close to a parabolic shape. However, by analysing the temporal
variance of the instantaneous velocity profiles of different hematocrits, we
have observed a substantial increase of the instantaneous velocity fluctuations
by increasing the hematocrit within the plasma flow. Besides, some possible
effects from the measurements accuracy and flow rate instabilities from the
syringe pump, this observation also suggests that there is a direct correlation
between the level of hematocrit and the temporal instantaneous velocity
fluctuations
Confocal micro-PIV measurements of three-dimensional profiles of cell suspension flow in a square microchannel
A detailed measurement of the blood flow velocity profile in microchannels in vitro is fundamental to better understand the biomechanics of microcirculation. Therefore it is very important to determine the influence of suspended blood cells on the flow behaviour with high accuracy and spatial resolution. We measured the flow of blood cells suspended in a physiological fluid within a square microchannel using a confocal particle image velocimetry (PIV) system and compared it to pure water. This emerging technology combines a conventional PIV system with a spinning confocal microscope and has the ability to obtain high-resolution images and three-dimensional (3D) optical section velocity measurements. The good agreement obtained between the measured and estimated results suggests that macroscale flow theory can be used to predict the flow behaviour of a homogeneous fluid within a 100 μm square microchannel. Our results also demonstrated the potential of the confocal system for generating 3D profiles and consequently obtaining detailed information on microscale effects in microchannels using both homogeneous and non-homogeneous fluids, such
as a suspension of blood cells. Furthermore, the results obtained from our confocal micro-PIV system show the ability of this system to measure velocities up to 0.52 mm s−1 in a blood cell suspension fluid
Velocity measurements of physiological flows in microchannels using a confocal micro-PIV system
The detail measurements of velocity profiles of in vitro blood
flow in micorchannels are fundamental for a better understanding
on the biomechanics of the microcirculation. Despite the high
amount of research in microcirculation, there is not yet any
detailed experimental information about flow velocity profiles,
RBCs deformability and aggregation in microvessels (diameter in
the order of 100μm or less). These lack of knowledge is mainly
due to the absence of adequate techniques to measure and
quantitatively evaluate fluid mechanical effects at a microscopic
level [1, 2].
During the years the most research work in this area has focused
in experimental studies using techniques such as laser Doppler
anemometry (LDA) or conventional particle image velocimetry
(PIV). However, due to limitations of those techniques to study
effects at a micro-scale level, Meinhart and his colleagues [3] have
proposed a measurement technique that combines the PIV system
with an inverted epi-fluorescent microscope, which increases the
resolution of the conventional PIV systems [3]. More recently,
considerable progress in the development of confocal microscopy
and consequent advantages of this microscope over the
conventional microscopes [4, 5] have led to a new technique
known as confocal micro-PIV. This technique combines the
conventional PIV system with a spinning disk confocal
microscope (SDCM). Due to its outstanding spatial filtering
technique together with the multiple point light illumination
system, this kind of microscope has the ability to obtain in-focus
images with optical thickness less than 1 μm, task extremely
difficult to be achieved by using a conventional microscope. As a
result, by combining SDCM with the conventional PIV system it
is possible to achieve a PIV system with not only extremely high
spatial resolution but also with capability to generate 3D velocity
profiles.
The main purpose of the present study is to evaluate the
performance of our confocal micro-PIV system in order to
investigate its ability to study the behaviour of non-homogenous
fluids such as physiological fluids
- …