44,413 research outputs found
Device for measuring the contour of a surface
Light from a source is imaged by a lens onto a surface so that the energy from the source is concentrated into a spot. As the spot across the surface is scanned, the surface moves relative to the point of perfect focus. When the surface moves away from perfect focus the spot increases in size, while the total energy in the spot remains virtually constant. The lens then reimages the light reflected by the surface onto two detectors through two different sized apertures. The light energy going to the two detectors is separated by a beam splitter. This second path of the light energy through the lens further defocuses the spot, but as a result of the different sizes of the apertures in each light detector path, the amount of defocus for each is different. The ratio of the outputs of the two detectors which are indicative of the contour of the surface is obtained by a divider
Identifying studies for systematic reviews - An example from medical imaging
Objectives: To determine if published figures on the proportion of articles included in systematic reviews and identified in electronic databases are applicable to an example from medical imaging.
Methods: A systematic review was performed. Additionally, sensitivity and precision of a MEDLINE search were compared with values from three published searches, each customized for a specific field.
Results: All articles included in the systematic review were in electronic databases. The MEDLINE search had low precision compared with searches in other fields.
Conclusions: in a specific area of medical imaging, electronic databases, including MEDLINE, are reliable sources of articles
Mapping CS in Starburst Galaxies: Disentangling and Characterising Dense Gas
Aims. We observe the dense gas tracer CS in two nearby starburst galaxies to
determine how the conditions of the dense gas varies across the circumnuclear
regions in starburst galaxies. Methods. Using the IRAM-30m telescope, we mapped
the distribution of the CS(2-1) and CS(3-2) lines in the circumnuclear regions
of the nearby starburst galaxies NGC 3079 and NGC 6946. We also detected the
formaldehyde (H2CO) and methanol (CH3OH) in both galaxies. We marginally detect
the isotopologue C34S. Results. We calculate column densities under LTE
conditions for CS and CH3OH. Using the detections accumulated here to guide our
inputs, we link a time and depth dependent chemical model with a molecular line
radiative transfer model; we reproduce the observations, showing how conditions
where CS is present are likely to vary away from the galactic centres.
Conclusions. Using the rotational diagram method for CH3OH, we obtain a lower
limit temperature of 14 K. In addition to this, by comparing the chemical and
radiative transfer models to observations, we determine the properties of the
dense gas as traced by CS (and CH3OH). We also estimate the quantity of the
dense gas. We find that, provided that there are a between 10^5 and 10^6 dense
cores in our beam, for both target galaxies, emission of CS from warm (T = 100
- 400 K), dense (n(H2) = 10^5-6 cm-3) cores, possibly with a high cosmic ray
ionisation rate (zeta = 100 zeta0) best describes conditions for our central
pointing. In NGC 6946, conditions are generally cooler and/or less dense
further from the centre, whereas in NGC 3079, conditions are more uniform. The
inclusion of shocks allows for more efficient CS formation, leading to an order
of magnitude less dense gas being required to replicate observations in some
cases.Comment: 14 pages, 10 figures, accepted to A&
Spectrometer integrated with a facsimile camera
This invention integrates a spectrometer capability with the basic imagery function of facsimile cameras without significantly increasing mechanical or optical complexity, or interfering with the imaging function. The invention consists of a group of photodetectors arranged in a linear array in the focal plane of the facsimile camera with a separate narrow band interference filter centered over each photodetector. The interference filter photodetector array is on a line in the focal plane of the facsimile camera along the direction of image motion due to the rotation of the facsimile camera's vertical mirror. As the image of the picture element of interest travels down the interference filter photodetector array, the photodetector outputs are synchronously selected and sampled to provide spectral information on the single picture element
Electronic structure induced reconstruction and magnetic ordering at the LaAlOSrTiO interface
Using local density approximation (LDA) calculations we predict
GdFeO-like rotation of TiO octahedra at the -type interface between
LaAlO and SrTiO. The narrowing of the Ti bandwidth which results
means that for very modest values of , LDA calculations predict charge
and spin ordering at the interface. Recent experimental evidence for magnetic
interface ordering may be understood in terms of the close proximity of an
antiferromagnetic insulating ground state to a ferromagnetic metallic excited
state
A colimit decomposition for homotopy algebras in Cat
Badzioch showed that in the category of simplicial sets each homotopy algebra
of a Lawvere theory is weakly equivalent to a strict algebra. In seeking to
extend this result to other contexts Rosicky observed a key point to be that
each homotopy colimit in simplicial sets admits a decomposition into a homotopy
sifted colimit of finite coproducts, and asked the author whether a similar
decomposition holds in the 2-category of categories Cat. Our purpose in the
present paper is to show that this is the case.Comment: Some notation changed; small amount of exposition added in intr
- …