19 research outputs found

    Towards Fluorescence-Guided Head and Neck Cancer Surgery

    Get PDF
    __Abstract__ Fluorescence-guided cancer surgery provides real-time intraoperative optical feedback on tumor margins and could therefore revolutionize surgical outcomes and patient survival. This thesis focuses on current modalities and cancer targeting strategies of fluorescence-guided head and neck cancer surgery. It was demonstrated in preclinical studies that head and neck tumors could be detected by targeting various hallmarks of cancer. The fundamental limitations of the technique are explained and future perspectives on its use are provided. When practical and technical surgical issues are considered with care, fluorescence imaging can be a very powerful intraoperative tool in guiding the future head and neck surgeon towards radical resection and optimal clinical results

    Optical Imaging of Tumor Response to Hyperbaric Oxygen Treatment and Irradiation in an Orthotopic Mouse Model of Head and Neck Squamous Cell Carcinoma

    Get PDF
    Purpose: Hyperbaric oxygen therapy (HBOT) is used in the treatment of radiation-induced tissue injury but its effect on (residual) tumor tissue is indistinct and therefore investigated in this study. Procedures: Orthotopic FaDu tumors were established in mice, and the response of the (irradiated) tumors to HBOT was monitored by bioluminescence imaging. Near infrared fluorescence imaging using AngioSense750 and Hypoxisense680 was applied to detect tumor vascular permeability and hypoxia. Results: HBOT treatment resulted in accelerated growth of non-irradiated tumors, but mouse survival was improved. Tumor vascular leakiness and hypoxia were enhanced after HBOT, whereas histological characteristics, epithelial-to-mesenchymal transition markers, and metastatic incidence were not influenced. Conclusions: Squamous cell carcinoma responds to HBOT with respect to tumor growth, vascular permeability, and hypoxia, which may have implications for its use in cancer patients. The ability to longitudinally analyze tumor characteristics highlights the versatility and potential of optical imaging methods in oncological research

    Detecting head and neck lymph node metastases with white light reflectance spectroscopy; a pilot study

    Get PDF
    Introduction: A challenge in the treatment of patients with head and neck cancer is the management of occult cervical lymph node (LN) metastases. Single-fiber reflectance (SFR) spectroscopy has the potential to detect physiological tissue changes that occur in a positive LN. This pilot study aimed to investigate whether SFR spectroscopy could serve as an alternative or additional technique to detect cervical lymph node metastases. Materials and Methods: We performed intraoperative SFR spectroscopy measurements of LNs with and without malignancies. We analyzed if physiological and scattering parameters were significantly altered in positive LNs. Results: Nine patients with a total of nineteen LNs were included. Three parameters, blood volume fraction (BVF), microvascular saturation (StO2), and Rayleigh amplitude, were significantly lower in positive LNs. They were combined into one optical parameter ‘delta’, using discriminant analysis. Delta was significantly decreased in positive LNs, p = 0,0006. It had a high diagnostic accuracy where the sensitivity, specificity, PPV, and NPV were 90,0%, 88.9%, 90,0%, and 88.9%, respectively. The area under the ROC curve was 96.7% (95% confidence interval 89.7–100.0%). Conclusion: This proof of principle study is a first step in the development of an SFR spectroscopy technique to detect LN metastases in real time. A next step towards this goal is replicating these results in LNs with smaller metastases and in a larger cohort of patients. This future study will combine SFR spectroscopy with fine-needle aspiration, using the same needle, to perform preoperative in vivo measurements.</p

    Characterization and Evaluation of the Artemis Camera for Fluorescence-Guided Cancer Surgery

    Get PDF
    Purpose: Near-infrared (NIR) fluorescence imaging can provide the surgeon with real-time visualization of, e.g., tumor margins and lymph nodes. We describe and evaluate the Artemis, a novel, handheld NIR fluorescence camera.Procedures: We evaluated minimal detectable cell numbers (FaDu-luc2, 7D12-IRDye 800CW), preclinical intraoperative detection of sentinel lymph nodes (SLN) using indocyanine green (ICG), and of orthotopic tongue tumors using 7D12-800CW. Results were compared with the Pearl imager. Clinically, three patients with liver metastases were imaged using ICG.Results: Minimum detectable cell counts for Artemis and Pearl were 2 × 105 and 4 × 104 cells, respectively. In vivo, seven SLNs were detected in four mice with both cameras. Orthotopic OSC-19-luc2-cGFP tongue tumors were clearly identifiable, and a minimum FaDu-luc2 tumor size of 1 mm3 could be identified. Six human malignant lesions were identified during three liver surgery procedures.Conclusions: Based on this study, the Artemis system has demonstrated its utility in fluorescence-guided cancer surgery

    EpCAM as multi-tumour target for near-infrared fluorescence guided surgery

    Get PDF
    Background: Evaluation of resection margins during cancer surgery can be challenging, often resulting in incomplete tumour removal. Fluorescence-guided surgery (FGS) aims to aid the surgeon to visualize tumours and resection margins during surgery. FGS relies on a clinically applicable imaging system in combination with a specific tumour-targeting contrast agent. In this study EpCAM (epithelial cell adhesion molecule) is evaluated as target for FGS in combination with the novel Artemis imaging system. Methods: The NIR fluorophore IRDye800CW was conjugated to the well-established EpCAM specific monoclonal antibody 323/A3 and an isotype IgG1 as control. The anti-EpCAM/800CW conjugate was stable in serum and showed preserved binding capacity as evaluated on EpCAM positive and negative cell lines, using flow cytometry and cell-based plate assays. Four clinically relevant orthotopic tumour models, i.e. colorectal cancer, breast cancer, head and neck cancer, and peritonitis carcinomatosa, were used to evaluate the performance of the anti-EpCAM agent with the clinically validated Artemis imaging system. The Pearl Impulse small animal imaging system was used as reference. The specificity of the NIRF signal was confirmed using bioluminescence imaging and green-fluorescent protein. Results: All tumour types could clearly be delineated and resected 72 h after injection of the imaging agent. Using NIRF imaging millimetre sized tumour nodules were detected that were invisible for the naked eye. Fluorescence microscopy demonstrated the distribution and tumour specificity of the anti-EpCAM agent. Conclusions: This study shows the potential of an EpCAM specific NIR-fluorescent agent in combination with a clinically validated intraoperative imaging system to visualize various tumours during surgery

    Early and long-term morbidity after total laryngopharyngectomy

    Get PDF
    To determine the early and long-term morbidity of patients treated with a total laryngopharyngectomy and reconstruction using a jejunum interposition or gastric pull-up procedure. It is a retrospective study; and it is conducted in tertiairy referral center. Sixty-three patients were included in whom 70 reconstructions were performed (51 jejunum interpositions and 19 gastric pull-up procedures) between 1990 and 2007. The studied parameters were success rate of the reconstruction, early and long-term complication rate, and functional outcome including quality of life. Subjective quality of life analysis was determined by two questionnaires: the EORTC Quality of Life Questionnaire (QLQ)-C30 Dutch version 3.0, and the EORTC-Head and Neck (H & N 35). The success rates were 84 and 74%, respectively. The procedures were associated with a high complication rate (63% after jejunum interposition and 89% after gastric pull-up), and a lengthy rehabilitation. Surviving patients were found to have a good long-term quality of life. Complete oral intake was achieved in 97%, and speech rehabilitation in 95%. These procedures are associated with significant morbidity, high complication rates, lengthy rehabilitation, but a good long-term quality of life

    Optical Imaging of Tumor Response to Hyperbaric Oxygen Treatment and Irradiation in an Orthotopic Mouse Model of Head and Neck Squamous Cell Carcinoma

    Get PDF
    PURPOSE: Hyperbaric oxygen therapy (HBOT) is used in the treatment of radiation-induced tissue injury but its effect on (residual) tumor tissue is indistinct and therefore investigated in this study. PROCEDURES: Orthotopic FaDu tumors were established in mice, and the response of the (irradiated) tumors to HBOT was monitored by bioluminescence imaging. Near infrared fluorescence imaging using AngioSense750 and Hypoxisense680 was applied to detect tumor vascular permeability and hypoxia. RESULTS: HBOT treatment resulted in accelerated growth of non-irradiated tumors, but mouse survival was improved. Tumor vascular leakiness and hypoxia were enhanced after HBOT, whereas histological characteristics, epithelial-to-mesenchymal transition markers, and metastatic incidence were not influenced. CONCLUSIONS: Squamous cell carcinoma responds to HBOT with respect to tumor growth, vascular permeability, and hypoxia, which may have implications for its use in cancer patients. The ability to longitudinally analyze tumor characteristics highlights the versatility and potential of optical imaging methods in oncological research. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11307-015-0834-8) contains supplementary material, which is available to authorized users

    Intraoperative Assessment of the Resection Specimen Facilitates Achievement of Adequate Margins in Oral Carcinoma

    Get PDF
    Background: Inadequate resection margins in oral cavity squamous cell carcinoma have an adverse effect on patient outcome. Intraoperative assessment provides immediate feedback enabling the surgeon to achieve adequate resection margins. The goal of this study was to evaluate the value of specimen-driven intraoperative assessment by comparing the margin status in the period before and the period after the introduction of specimen-driven assessment as a standard of care (period 2010–2012 vs period 2013–2017). Methods: A cohort of patients surgically treated for oral squamous cell carcinoma at the Erasmus MC Cancer Institute, Rotterdam, between 2010–2012 was studied retrospectively and compared to results of a prospectively collected cohort between 2013–2017. The frequency, type and results of intraoperative assessment of resection margins were analyzed. Results: One hundred seventy-four patients were included from 2010–2012, 241 patients were included from 2013–2017. An increase in the frequency of specimen-driven assessment was seen between the two periods, from 5% in 2010–2012 to 34% in 2013–2017. When performing specimen-driven assessment, 16% tumor-positive resection margins were found in 2013–2017, compared to 43% tumor-positive resection margins overall in 2010–2012. We found a significant reduction of inadequate resection margins for specimen-driven intraoperative assessment (p < 0.001). Also, tumor recurrence significantly decreased, and dise
    corecore