226 research outputs found

    Unintended complication of intracranial subdural hematoma after percutaneous epidural neuroplasty.

    Get PDF
    Percutaneous epidural neuroplasty (PEN) is a known interventional technique for the management of spinal pain. As with any procedures, PEN is associated with complications ranging from mild to more serious ones. We present a case of intracranial subdural hematoma after PEN requiring surgical evacuation. We review the relevant literature and discuss possible complications of PEN and patholophysiology of intracranial subdural hematoma after PEN

    Radiculopathy as Delayed Presentations of Retained Spinal Bullet.

    Get PDF
    Bullet injuries to the spine may cause injury to the anatomical structures with or without neurologic deterioration. Most bullet injuries are acute, resulting from direct injury. However, in rare cases, delayed injury may occur, resulting in claudication. We report a case of intradural bullet at the L3-4 level with radiculopathy in a 30-year-old male. After surgical removal, radicular and claudicating pain were improved significantly, and motor power of the right leg also improved. We report the case of intradural bullet, which resulted in delayed radiculopathy

    Stereotactic guidance for navigated percutaneous sacroiliac joint fusion.

    Get PDF
    Arthrodesis of the sacroiliac joint (SIJ) for surgical treatment of SIJ dysfunction has regained interest among spine specialists. Current techniques described in the literature most often utilize intraoperative fluoroscopy to aid in implant placement; however, image guidance for SIJ fusion may allow for minimally invasive percutaneous instrumentation with more precise implant placement. In the following cases, we performed percutaneous stereotactic navigated sacroiliac instrumentation using O-armĀ® multidimensional surgical imaging with StealthStationĀ® navigation (Medtronic, Inc. Minneapolis, MN). Patients were positioned prone and an image-guidance reference frame was placed contralateral to the surgical site. O-armĀ® integrated with StealthStationĀ® allowed immediate auto-registration. The skin incision was planned with an image-guidance probe. An image-guided awl, drill and tap were utilized to choose a starting point and trajectory. Threaded titanium cage(s) packed with autograft and/or allograft were then placed. O-armĀ® image-guidance allowed for implant placement in the SIJ with a small skin incision. However, we could not track the cage depth position with our current system, and in one patient, the SIJ cage had to be revised secondary to the anterior breach of sacrum

    Antiretroviral Genotypic Resistance Mutations in HIV-1 Infected Korean Patients with Virologic Failure

    Get PDF
    Resistance assays are useful in guiding decisions for patients experiencing virologic failure (VF) during highly-active antiretroviral therapy (HAART). We investigated antiretroviral resistance mutations in 41 Korean human immunodeficiency virus type 1 (HIV-1) infected patients with VF and observed immunologic/virologic response 6 months after HAART regimen change. Mean HAART duration prior to resistance assay was 45.3Ā±27.5 months and commonly prescribed HAART regimens were zidovudine/lamivudine/nelfinavir (22.0%) and zidovudine/lamivudine/efavirenz (19.5%). Forty patients (97.6%) revealed intermediate to high-level resistance to equal or more than 2 antiretroviral drugs among prescribed HAART regimen. M184V/I mutation was observed in 36 patients (87.7%) followed by T215Y/F (41.5%) and M46I/L (34%). Six months after resistance assay and HAART regimen change, median CD4+ T cell count increased from 168 cells/ĀµL (interquartile range [IQR], 62-253) to 276 cells/ĀµL (IQR, 153-381) and log viral load decreased from 4.65 copies/mL (IQR, 4.18-5.00) to 1.91 copies/mL (IQR, 1.10-3.60) (P<0.001 for both values). The number of patients who accomplished viral load <400 copies/mL was 26 (63.4%) at 6 months follow-up. In conclusion, many Korean HIV-1 infected patients with VF are harboring strains with multiple resistance mutations and immunologic/virologic parameters are improved significantly after genotypic resistance assay and HAART regimen change

    Titanium Plate Fixation for a Dehisced Sternum Following Coronary Artery Bypass Grafting: A Case Report

    Get PDF
    Sternal dehiscence is one of the most troublesome complications following cardiac surgery. Treatment failure and consequent lethal results are very common, even with all the efforts to resolve sternal dehiscence such as removal of infectious tissue, muscle flap interposition, and sternal rewiring. We report on a case of sternal osteomyelitis following coronary artery bypass grafting that was successfully treated with wide sternal resection, titanium plate fixation, and pectoralis muscle flap interposition

    A Case of Acute Ventricular Capture Threshold Rise Associated with Flecainide Acetate

    Get PDF
    Antiarrhythmic agents may increase capture threshold, but this is rarely of clinical significance. Flecainide acetate, a class IC agent, is reported to have a significant effect on the myocardial capture threshold. In this presentation, we report the case of a 72-year-old male, with a previously implanted VVI pacemaker due to sick sinus syndrome, who was treated with flecainide acetate for paroxysmal atrial arrhythmia control. During the fifteenth day of treatment, an abrupt rise in the ventricular capture threshold with ventricular pacing failure was noted. The capture threshold decreased two days after discontinuation of flecainide acetate

    Microstructural evolution induced by micro-cracking during fast lithiation of single-crystalline silicon

    Get PDF
    h i g h l i g h t s Lithiation of Si results in various microstructures depending of crystal orientation. A complex vein-like microstructure of Li x Si was observed in {100} oriented Si. Micro-cracks provide a fast path for Li diffusion and cause a non-uniform lithiation. Crystalline Li x Si plays an important role in micro-crack generation. a r t i c l e i n f o t r a c t We report observations of microstructural changes in {100} and {110} oriented silicon wafers during initial lithiation under relatively high current densities. Evolution of the microstructure during lithiation was found to depend on the crystallographic orientation of the silicon wafers. In {110} silicon wafers, the phase boundary between silicon and Li x Si remained flat and parallel to the surface. In contrast, lithiation of the {100} oriented substrate resulted in a complex vein-like microstructure of Li x Si in a crystalline silicon matrix. A simple calculation demonstrates that the formation of such structures is energetically unfavorable in the absence of defects due to the large hydrostatic stresses that develop. However, TEM observations revealed micro-cracks in the {100} silicon wafer, which can create fast diffusion paths for lithium and contribute to the formation of a complex vein-like Li x Si network. This defect-induced microstructure can significantly affect the subsequent delithiation and following cycles, resulting in degradation of the electrode

    Association between apolipoprotein E genotype, chronic liver disease, and hepatitis B virus

    Get PDF
    Background/AimsApolipoprotein E (ApoE) plays an important role in regulating lipid and lipoprotein metabolism, and ApoE genotypes are known to affect plasma lipoprotein concentrations. We investigated whether ApoE genotype determines the disease outcome in hepatitis B virus (HBV)-infected individuals, and verified the association between ApoE genotype and the occurrence of hepatocellular carcinoma (HCC) in patients with chronic liver diseases of various etiologies.MethodsThis hospital-based, case-controlled study enrolled 156 subjects (47 healthy controls, 50 HBV-related liver cirrhosis patients, and 59 HCC patients). ApoE genotypes were determined using PCR-based ApoE genotyping kits. The biological significance of ApoE genotype was verified by measuring serum ApoE levels using an ELISA kits.ResultsThe Īµ3 allele was the most common allele, with allele frequencies among the entire cohort of 5.8%, 84.3%, and 9.9% for the Īµ2, Īµ3, and Īµ4 alleles, respectively. Significantly more of those patients carrying the Īµ3/3 genotype had developed liver cirrhosis compared to the control subjects. Being an ApoE4 carrier was associated with a lower probability of developing liver cirrhosis. The allele frequencies and genotype distribution of ApoE did not differ significantly between the liver cirrhosis and HCC patients. The serum level of ApoE was significantly higher in patients with liver cirrhosis than in the healthy controls, but did not differ significantly with the ApoE genotype.ConclusionsThe ApoE Īµ3/3 genotype frequency was higher in patients with HBV-associated liver cirrhosis than in the controls
    • ā€¦
    corecore