6 research outputs found

    Corrosion in Haas expanders with and without use of an antimicrobial agent: an in situ study

    Full text link
    OBJECTIVES: The purpose of this study was to evaluate in situ the occurrence of corrosion in the soldering point areas between the wire, silver brazing and band in Haas expanders. MATERIAL AND METHODS: Thirty-four 7-12-year-old patients who needed maxillary expansion with a Haas expander were randomly assigned to two groups of 17 individuals each, according to the oral hygiene protocol adopted during the orthodontic treatment: Group I (control), toothbrushing with a fluoride dentifrice and Group II (experimental), toothbrushing with the same dentifrice plus 0.12% chlorhexidine gluconate (Periogard(®)) mouthrinses twice a week. The appliances were removed after approximately 4 months. Fragments of the appliances containing a metallic band with a soldered wire were sectioned at random for examination by stereomicroscopy, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). Data were analyzed statistically by Fisher's test at 5% significance level. RESULTS: The analysis by optical microscopy revealed areas with color change suggestive of corrosion in the soldering point areas joining the band and the wire in all specimens of both groups, with no statistically significant difference between the groups (p=1). The peaks of chemical elements (Ni, Fe, Cr, O, C and P) revealed by EDS were also similar in both groups. CONCLUSION: Color changes and peaks of chemical elements suggestive of corrosion were observed in the soldering point areas between the wire, silver brazing and band in both control and experimental groups, which indicate that the 0.12% chlorhexidine gluconate mouthrinses did not influence the occurrence of corrosion in situ

    Electrochemical behavior and pH stability of artificial salivas for corrosion tests Comportamento eletroquímico e estabilidade de pH de salivas artificiais para testes de corrosão

    No full text
    It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.<br>Admite-se que as composições das salivas artificiais são semelhantes àquela da saliva humana. A utilização de soluções de composições distintas em estudos de corrosão in vitro, entretanto, pode fazer com que eletrólitos diferentes exibam diferenças no processo corrosivo e na estabilidade eletroquímica. Este estudo avaliou quatro salivas artificiais em relação a estabilidade do pH em função do tempo, potencial redox e resposta à polarização de um eletrodo de platina inerte. As soluções testadas foram: meio SAGF, saliva artificial Mondelli, saliva artificial UFRJ (preparada pela Faculdade de Farmácia da Universidade Federal do Rio de Janeiro, RJ, Brasil) e saliva artificial USP-RP (preparada pela Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, SP, Brasil). Foi observado que as variações de pH foram menores que 1 unidade durante as 50 horas de ensaio. O meio SAGF e as soluções UFRJ e USP-RP exibiram características mais oxidantes, enquanto a solução Mondelli apresentou propriedades redutoras. A polarização anódica mostrou oxidação dos eletrólitos avaliados a potenciais inferiores a +600 mV ECS. Foi observado que as soluções UFRJ e USP-RP são mais facilmente oxidadas e reduzidas se comparadas com as soluções Mondelli e SAGF

    Removable Partial Denture with Bar or Plate: How should We Decide?

    No full text
    corecore