313 research outputs found
Recommended from our members
Noise reduction of dental drill noise
Dental drills produce a characteristic noise that is uncomfortable for patients and is also known to be harmful to dentists under prolonged exposure. It is therefore desirable to protect the patient and dentist whilst allowing two-way communication, which will require a headphone - type system. Re-establishing good communication between the dentist and patient will be achieved through a combination of three noise cancellation technologies, namely, Passive Noise Control (PNC), Adaptive Filtering (AF) and Active Noise Control (ANC). This paper describes how far a test-rig has been developed to achieve sufficient noise reduction that the uncomfortable noise can no longer be heard
Recommended from our members
Active noise control on high frequency narrow band dental drill noise: Preliminary results
Dental drills produce a characteristic noise that is uncomfortable for patients and is also known to be harmful to dentists under prolonged exposure. It is therefore desirable to protect the patient and dentist whilst allowing two-way communication. A solution is to use a combination of the three main noise cancellation methods, namely, Passive Noise Control, Adaptive Filtering and Active Noise Control. Dental drill noise occurs at very high frequency ranges in relation to conventional ANC, typically 2kHz to 6kHz and it has a narrow band characteristic due to the direct relation of the noise to the rotational speed of the bearing. This paper presents a design of an experimental rig where first applications of ANC on dental drill noise are executed using the standard filtered reference Least Mean Square (FXLMS) algorithm. The secondary path is kept as simple as possible, due to the high frequency range of interest, and hence is chosen as the space between headphone loudspeaker and error microphone placed in the ear (input of the headphone loudspeaker and the output of the error microphone). A standard headphone loudspeaker is used for the control source and the microphone inside of an âEar and Cheek Simulator Type 43AGâ is used as the error microphone. The secondary path transfer function is obtained and preliminary results of the application of ANC are discussed
Recommended from our members
Testing medical drills for noise emissions
Copyright @ 2007 TUT PressA comparative study of drills from a range of manufacturers was carried out in the laboratory. These tests were made under a variety of loading conditions to assess the characteristics of the noise likely in the dentistâs surgery. Details of the test setup are given, and some of the issues in analysing the results considered. Simultaneous Recordings were made of the noise on a minidisk recorder, a hand held sound meter, and a sound analyser. The results from these are considered. These are significant for dentistâs hearing, and the patientâs perception of visiting the dentists. The performance of different designs of pneumatic drill varies much with type and load
Recommended from our members
Dental drill noise reduction using a combination of active noise control, passive noise control and adaptive filtering
Dental drills produce a characteristic high frequency, narrow band noise that is uncomfortable for patients and is also known to be harmful to dentists under prolonged exposure. It is therefore desirable to protect the patient and dentist whilst allowing two-way communication. A solution is to use a combination of the three main noise control methods, namely, Passive Noise Control (PNC), Adaptive Filtering (AF) and Active Noise Control (ANC). This paper discusses the application of the three methods to reduce dental drill noise while allowing two-way communication. Experimental setup for measuring the noise reduction by PNC is explained and results from different headphones and headphone types are presented. The implementation and results of an AF system using the Least Mean Square (LMS) algorithm are shown. ANC requires a modification of the LMS algorithm due to the introduction of the electro-acoustical cancellation path transfer function to compensate for the delays introduced by the control system. Therefore a cancellation path transfer function modeling method based on the filtered reference LMS (FXLMS) algorithm is presented along with preliminary results of the implementation
Recommended from our members
Active noise control for high frequencies
There are many applications that can benefit from Active Noise Control (ANC) such as in aircraft cabins and air conditioning ducts, i.e. in situations where technology interferes with human hearing in a harmful way or disrupts communication. Headsets with analogue ANC circuits have been used in the armed forces for attenuating frequencies below 1 kHz, which when combined with passive filtering offers protection across the whole frequency range of human hearing. A dental surgery is also a noisy environment; in which dental drill noise is commonly off-putting for many patients and is believed to harm the dentistâs hearing over a long period of time. However, dealing with dental drill noise is a different proposition from the applications mentioned above as the frequency range of the peak amplitudes goes from approximately 1.5 kHz to 12 kHz, whereas conventional ANC applications consider a maximum of 1.5 kHz. This paper will review the application of ANC at low frequencies and justify an approach for dealing with dental noise using digital technologies at higher frequencies. The limits of current ANC technologies will be highlighted and the means of improving performance for this dental application will be explored. In particular, technicalities of implementing filtering algorithms on a Digital Signal Processor will be addressed
Recommended from our members
Real-time adaptive filtering of dental drill noise using a digital signal processor
The application of noise reduction methods requires the integration of acoustics engineering and digital signal processing, which is well served by a mechatronic approach as described in this paper. The Normalised Least Mean Square (NLMS) algorithm is implemented on the Texas Instruments TMS320C6713 DSK Digital Signal Processor (DSP) as an adaptive digital filter for dental drill noise. Blocks within the Matlab/Simulink Signal Processing Blockset and the Embedded Target for TI C6000 DSP family are used. A working model of the algorithm is then transferred to the Code Composer Studio (CCS), where the desired code can be linked and transferred to the target DSP. The experimental rig comprises a noise reference microphone, a microphone for the desired signal, the DSK and loudspeakers. Different load situations of the dental drill are considered as the noise characteristics change when the drill load changes. The result is that annoying drill noise peaks, which occur in a frequency range from 1.5 kHz to 10 kHz, are filtered out adaptively by the DSP. Additionally a schematic design for its implementation in a dentistâs surgery will also be presented
Recommended from our members
Experimental and bond graph based sensitivity calculations for micro-scale robust engineering design
Copyright @ 2005 IEEEBond graph modeling and sensitivity analysis are used to provide a platform for the robust design of a small mechatronic device, a behind-the-ear (BTE) hearing aid. Two key components of the device, namely the telecoil and the receiver, are considered. Experimental measurements, bond graph simulation models and analytic sensitivity analysis are used to investigate the interaction between these components in order to gain insight into the effect of component placement on the robustness of the final product
Microsatellite development for the genus Guibourtia (Fabaceae, Caesalpinioideae) reveals diploid and polyploid species
Premise of the study: Nuclear microsatellites (nSSRs) were designed for Guibourtia tessmannii (Fabaceae, Caesalpinioideae), a highly exploited African timber tree, to study population genetic structure and gene flow.
Methods and Results: We developed 16 polymorphic nSSRs from a genomic library tested in three populations of G. tessmannii and two populations of G. coleosperma. These nSSRs display three to 14 alleles per locus (mean 8.94) in G. tessmannii. Cross-amplification tests in nine congeneric species demonstrated that the genus Guibourtia contains diploid and polyploid species. Flow cytometry results combined with nSSR profiles suggest that G. tessmannii is octoploid.
Conclusions: nSSRs revealed that African Guibourtia species include both diploid and polyploid species. These markers will provide information on the mating system, patterns of gene flow, and genetic structure of African Guibourtia species
Function Approximation Using Probabilistic Fuzzy Systems
We consider function approximation by fuzzy systems. Fuzzy systems are typically used for approximating deterministic functions, in which the stochastic uncertainty is ignored. We propose probabilistic fuzzy systems i
The European Union, borders and conflict transformation: the case of Cyprus
Much of the existing literature on the European Union (EU), conflict transformation and border dynamics has been premised on the assumption that the nature of the border determines EU intervention and the consequences that flow from this in terms of EU impact. The article aims to transcend this literature through assessing how domestic interpretations influence EU border transformation in conflict situations, taking Cyprus as a case study. Moreover, the objective is to fuse the literature on EU bordering impact and perceptions of the EUâs normative projection in conflict resolution. Pursuing this line of inquiry is an attempt to depart from the notion of borders being constructed solely by unidirectional EU logics of engagement or bordering practices to a conceptualization of the border as co-constituted space, where the interpretations of the EUâs normative projections by conflict parties, and the strategies that they pursue, can determine the relative openness of the EU border
- âŚ