2,328 research outputs found

    Pointer States Via Engineered Dissipation

    Get PDF
    Pointer states are long-lasting high-fidelity states in open quantum systems. We show how any pure state in a non-Markovian open quantum system can be made to behave as a pointer state by suitably engineering the coupling to the environment via open-loop periodic control. Engineered pointer states are constructed as approximate fixed points of the controlled open-system dynamics, in such a way that they are guaranteed to survive over a long time with a fidelity determined by the relative precision with which the dynamics is engineered. We provide quantitative minimum-fidelity bounds by identifying symmetry and ergodicity conditions that the decoherence-inducing perturbation must obey in the presence of control, and develop explicit pulse sequences for engineering any desired set of orthogonal states as pointer states. These general control protocols are validated through exact numerical simulations as well as semiclassical approximations in realistic single- and two-qubit dissipative systems. We also examine the role of control imperfections, and show that while pointer-state engineering protocols are highly robust in the presence of systematic pulse errors, the latter can also lead to unintended pointer-state generation in dynamical decoupling implementations, explaining the initial-state selectivity observed in recent experiments

    Pre-corneal tear film thickness in humans measured with a novel technique.

    Get PDF
    PurposeThe purpose of this work was to gather preliminary data in normals and dry eye subjects, using a new, non-invasive imaging platform to measure the thickness of pre-corneal tear film.MethodsHuman subjects were screened for dry eye and classified as dry or normal. Tear film thickness over the inferior paracentral cornea was measured using laser illumination and a complementary metal-oxide-semiconductor (CMOS) camera. A previously developed mathematical model was used to calculate the thickness of the tear film by applying the principle of spatial auto-correlation function (ACF).ResultsMean tear film thickness values (±SD) were 3.05 μm (0.20) and 2.48 μm (0.32) on the initial visit for normals (n=18) and dry eye subjects (n=22), respectively, and were significantly different (p<0.001, 2-sample t-test). Repeatability was good between visit 1 and 2 for normals (intraclass correlation coefficient [ICC]=0.935) and dry eye subjects (ICC=0.950). Tear film thickness increased above baseline for the dry eye subjects following viscous drop instillation and remained significantly elevated for up to approximately 32 min (n=20; p<0.05 until 32 min; general linear mixed model and Dunnett's tests).ConclusionsThis technique for imaging the ocular surface appears to provide tear thickness values in agreement with other non-invasive methods. Moreover, the technique can differentiate between normal and dry eye patient types

    Chiral symmetry breaking in QED3{\rm QED}_{3} in presence of irrelevant interactions: a renormalization group study

    Full text link
    Motivated by recent theoretical approaches to high temperature superconductivity, we study dynamical mass generation in three dimensional quantum electrodynamics QED3{\rm QED}_{3}) in presence of irrelevant four-fermion quartic terms. The problem is reformulated in terms of the renormalization group flows of certain four-fermion couplings and charge, and then studied in the limit of large number of fermion flavors NN. We find that the critical number of fermions NcN_c below which the mass becomes dynamically generated depends continuously on a weak chiral-symmetry-breaking interaction. One-loop calculation in our gauge-invariant approach yields Nc0=6N_{c0} = 6 in pure QED3{\rm QED}_3. We also find that chiral-symmetry-preserving mass cannot become dynamically generated in pure QED3{\rm QED}_{3}.Comment: 7 pages, 7 figure

    Death from hemophagocytic lymphohistiocytosis syndrome due to generalized hemorrhage

    Get PDF
    Hemophagocytic lymphohistiocytosis (HLH) is the result of excessive cytokine release, leading to over-response by immune cells, such as macrophages and T lymphocytes. Here, we report a lethal case of HLH with a complete clinical course. The patient was a 45-year-old man with fever and chills since two months ago plus splenomegaly, hepatomegaly, and pancytopenia. The Anti-HBc IgM was positive, but the HBS antigen, anti-HCV, and HBS antibody were negative. Assessment for cirrhosis was carried out by FibroScan, which showed F4 grade. The biopsy sampling was impossible due to the low platelet count. During admission, generalized bleeding was developed and led to alveolar hemorrhage, which subsequently resulted in the patient's death. Liver necropsy certified the diagnosis of hemophagocytic syndrome. Overall, according to the reported case in this paper, it should be remembered that secondary HLH is an inflammatory phenomenon due to different conditions, such as latent newly-developed infections. © 2019

    Statistics of fluctuations for two types of crossover: from ballistic to diffusive regime and from orthogonal to unitary ensemble

    Full text link
    In our previous publication [Kogan et al, Phys. Rev. {\bf 48}, 9404 (1993)] we considered the issue of statistics of radiation diffusively propagating in a disordered medium. The consideration was in the framework of diagrammatic techniques and a new representation for the intensity distribution function in terms of connected diagrams only was proposed. Here we use similar approach to treat the issue of statistics in the regime of the crossover between ballistic and diffusive transport. We find that even small contribution from coherent component decreases by one half the intensity distribution function for small values of intensity and also produces oscillations of the distribution function. We also apply this method to study statistics of fluctuations of wave functions of chaotic electrons in a quantum dot in an arbitrary magnetic field, by calculating the single state local density in the regime of the crossover between the orthogonal and unitary ensemble.Comment: Revtex, 3 pages + 2 ps.figures in uuencoded file, a version which clarifies and unites the results of two previous submission

    Analysis of the compatibility of dental implant systems in fibula free flap reconstruction

    Get PDF
    As a result of major ablative surgery, head and neck oncology patients can be left with significant defects in the orofacial region. The resultant defect raises the need for advanced reconstruction techniques. The reconstruction in this region is aimed at restoring function and facial contour. The use of vascularised free flaps has revolutionised the reconstruction in the head and neck. Advances in reconstruction techniques have resulted in continuous improvement of oral rehabilitation. For example, endosteal implants are being used to restore the masticatory function by the way of prosthetic replacement of the dentition. Implant rehabilitation usually leads to improved facial appearance, function, restoration of speech and mastication. Suitable dental implant placement’s site requires satisfactory width, height and quality of bone. Reconstruction of hard tissue defects therefore will need to be tailored to meet the needs for implant placement. The aim of this feasibility study was to assess the compatibility of five standard commercially available dental implant systems (Biomet 3i, Nobel Biocare, Astra tech, Straumann and Ankylos) for placement into vascularised fibula graft during the reconstruction of oromandibular region. Radiographs (2D) of the lower extremities from 142 patients in the archives of the Department of Radiology in University College London Hospitals (UCLH) were analysed in this study. These radiographs were from 61 females and 81 males. Additionally, 60 unsexed dry fibular bones, 30 right sided, acquired from the collection of the Department of Anatomy, University College London (UCL) were also measured to account for the 3D factor. In the right fibula (dry bone), 90% of the samples measured had a width of 13.1 mm. While in the left fibula (dry bone), 90% of the samples measured had a width of 13.3 mm. Fibulas measured on radiographs had a width of 14.3 mm in 90% of the samples. The length ranges of the dental implants used in this study were: 7-13 mm (Biomet 3i), 10-13 mm (Nobel biocare), 8-13 mm (Astra Tech), 8-12 mm (Straumann ) and 8-11 mm (Ankylos). This study reached a conclusion that the width of fibula is sufficient for placement of most frequently used dental implants for oral rehabilitation after mandibular reconstructive procedures

    Schubert calculus and Gelfand-Zetlin polytopes

    Full text link
    We describe a new approach to the Schubert calculus on complete flag varieties using the volume polynomial associated with Gelfand-Zetlin polytopes. This approach allows us to compute the intersection products of Schubert cycles by intersecting faces of a polytope.Comment: 33 pages, 4 figures, introduction rewritten, Section 4 restructured, typos correcte
    corecore