150 research outputs found

    Development of solid-lubricated ball-screws for use in space

    Get PDF
    Ball-screws lubricated by solid lubricant films containing molybdenum disulphide are developed. The ball-screws (shaft diameter: phi 25 mm, length: 667 mm) were operated under a load of 40 to 120 N at a speed of 1.5 to 200 rpm at 10(exp -5) Pa. First, ball-screws made of stainless steel SUS 440C were studied using test equipment originally designed for this study. To reduce weight, the next step taken was to develop a ball-screw made of 6Al-4V-titanium. Long wear-life of more than 1 x 10(exp 7) revolutions was achieved with solid lubricated ball-screws made of SUS 440C and 6Al-4V-titanium in a hard vacuum. According to the surface profile of the shaft measured after 1 x 10(exp 7) revolutions, more solid lubricant remained on the surface of 6Al-4V-titanium than that of stainless steel. Auger and EPMA analysis confirmed lubrication was maintained by solid lubricant on nuts and screws after the lubricant films on the balls were worn off

    Ureterolithotripsy for a Ureteral Calculus at the Ureteroureterostomy of a Renal-transplant Recipient

    Get PDF
    We describe a 40-year-old living-donor renal-transplant recipient who underwent successful ureterolithotripsy. He had been on hemodialysis for >15 years pre-transplant and underwent ureteroureterostomy along with the surgery. One year post-transplant, ultrasound examination demonstrated hydronephrosis, and CT showed a 6-mm ureteral calculus at the ureteroureterostomy site. No pain and no elevated serum creatinine were present. As the ureter was easily accessed, we performed a ureterolithotripsy, which would confirm whether a suture caused the calculus. Despite ureteral tortuosity, laser stone fragmentation succeeded. The calculus was completely removed with an antegrade guidewire. Mild postoperative ureteral stenosis resolved with a temporary ureteral stent without balloon dilation. Ureterolithotripsy is effective even in renal transplant recipients with ureteroureterostomy

    Determination of the Major Impurity Radiators in the Reheat Mode Discharges in the Compact Helical System

    Get PDF
    Radiation brightness and impurity behaviors have been studied for reheat mode discharges in the Compact Helical System (CHS) by three different types of impurity diagnostics. Total radiation power measured by a pyroelectric detector significantly reduces after entering the reheat mode, whereas the line-averaged radiation brightness measured by an absolute extreme ultraviolet (AXUV) photodiode array increases especially for a center viewing chord due to the impurity accumulation in the plasma core. One possible reason for this opposite behavior between the two bolometric detectors is the reduced sensitivity of the AXUV photodiode for lower energy photons in vacuum ultraviolet (VUV) region. This speculation is supported by temporal evolutions of VUV spectra measured by a grazing incidence spectrometer. These results demonstrate that the comparison of three impurity diagnostics would be beneficial to the determination of the major impurity radiators and a comprehensive understanding of impurity behaviors in the reheat mode discharges

    Robotic Renal Autotransplantation: First Case Outside of North America

    Get PDF
    A 38-year-old woman with a 2.7-cm left ureteral stenosis requiring chronic ureteral stent exchange elected to undergo robotic renal autotransplantation. Left ureteropelvic junction obstruction (UPJO) was also suspected. Robotic donor nephrectomy contributed to the fine dissection for desmoplastic changes. The kidney was removed through a Gelport and examined on ice. UPJO was not seen. An end-to-side robotic anastomosis was created between the renal and external iliac vessels. The console time was 507 min, and the warm ischemia time was 4 min 5 sec. She became stent-free. Robotic renal autotransplantation is a new, minimally invasive approach to renal preservation
    corecore