10 research outputs found

    Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure.

    No full text
    Prosthetic elevated vacuum is a suspension method used to reduce daily volume changes of the residual limb. Evaluation of the effectiveness of these systems is limited due to a lack of correlation to actual socket air pressure, particularly during unconstrained movements. This may explain some of the variability in functional outcomes reported in the literature. Our objective was to develop a light-weight portable socket measurement system to quantify internal socket air pressure, temperature, and acceleration; and to present preliminary results from implementation with three transtibial prosthesis users with mechanical elevated vacuum pumps. Participants completed five functional tasks with and without the vacuum pumps actively connected, including the 2-Minute Walk test, 5-Times Sit-to-Stand test, 4-Square Step test, L-Test, and Figure-8 test. Results demonstrated different gait profiles and pressure ranges for each user. Two of the participants demonstrated substantially lower air pressure (higher vacuum) over time while the pump was active compared to inactive. The minimum air pressure measured for all participants was -34.6 ± 7.7 kPa. One participant did not show substantial changes in pressure over time for either pump condition. Functional task performance was not significantly different between pump conditions. Correlation with accelerometer readings indicated peak positive pressures occurred just following initial contact of the foot in early stance, and the most negative pressures (highest vacuum) were observed throughout swing. This study has demonstrated the use of a portable data logging tool that may serve the clinical and research communities to quantify the operation of elevated vacuum systems, and better understand the variability of mechanical pump operation and overall system performance

    Characterization of interfacial socket pressure in transhumeral prostheses: A case series

    No full text
    <div><p>One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user’s morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.</p></div

    Experimental results for participant 2.

    No full text
    <p>kPa denotes units of pressure in kilopascals. Note: The posterior pressure maps view are shown with slight medial rotation to reveal pressures around curve of the posterior axilla.</p

    Characterization of interfacial socket pressure in transhumeral prostheses: A case series - Fig 2

    No full text
    <p>Equilibration and calibration apparatuses, a. equilibration setup schematically described and demonstrated on a participant, b. calibration setup demonstrated on a participant.</p