194 research outputs found
Combination of linear classifiers using score function -- analysis of possible combination strategies
In this work, we addressed the issue of combining linear classifiers using
their score functions. The value of the scoring function depends on the
distance from the decision boundary. Two score functions have been tested and
four different combination strategies were investigated. During the
experimental study, the proposed approach was applied to the heterogeneous
ensemble and it was compared to two reference methods -- majority voting and
model averaging respectively. The comparison was made in terms of seven
different quality criteria. The result shows that combination strategies based
on simple average, and trimmed average are the best combination strategies of
the geometrical combination
Identification of amino acid residues lining the pore of a gap junction channel
Gap junctions represent a ubiquitous and integral part of multicellular organisms, providing the only conduit for direct exchange of nutrients, messengers and ions between neighboring cells. However, at the molecular level we have limited knowledge of their endogenous permeants and selectivity features. By probing the accessibility of systematically substituted cysteine residues to thiol blockers (a technique called SCAM), we have identified the pore-lining residues of a gap junction channel composed of Cx32. Analysis of 45 sites in perfused Xenopus oocyte pairs defined M3 as the major pore-lining helix, with M2 (open state) or M1 (closed state) also contributing to the wider cytoplasmic opening of the channel. Additional mapping of a close association between M3 and M4 allowed the helices of the low resolution map (Unger et al., 1999. Science. 283:1176–1180) to be tentatively assigned to the connexin transmembrane domains. Contrary to previous conceptions of the gap junction channel, the residues lining the pore are largely hydrophobic. This indicates that the selective permeabilities of this unique channel class may result from novel mechanisms, including complex van der Waals interactions of permeants with the pore wall, rather than mechanisms involving fixed charges or chelation chemistry as reported for other ion channels
FlashCam: A fully digital camera for CTA telescopes
The future Cherenkov Telescope Array (CTA) will consist of several tens of
telescopes of different mirror sizes. CTA will provide next generation
sensitivity to very high energy photons from few tens of GeV to >100 TeV.
Several focal plane instrumentation options are currently being evaluated
inside the CTA consortium. In this paper, the current status of the FlashCam
prototyping project is described. FlashCam is based on a fully digital camera
readout concept and features a clean separation between photon detector plane
and signal digitization/triggering electronics.Comment: In Proceedings of the 2012 Heidelberg Symposium on High Energy
Gamma-Ray Astronomy. All CTA contributions at arXiv:1211.184
Performance of a small size telescope (SST-1M) camera for gamma-ray astronomy with the Cherenkov Telescope Array
The foreseen implementations of the Small Size Telescopes (SST) in CTA will
provide unique insights into the highest energy gamma rays offering fundamental
means to discover and under- stand the sources populating the Galaxy and our
local neighborhood. Aiming at such a goal, the SST-1M is one of the three
different implementations that are being prototyped and tested for CTA. SST-1M
is a Davies-Cotton single mirror telescope equipped with a unique camera
technology based on SiPMs with demonstrated advantages over classical
photomultipliers in terms of duty-cycle. In this contribution, we describe the
telescope components, the camera, and the trigger and readout system. The
results of the commissioning of the camera using a dedicated test setup are
then presented. The performances of the camera first prototype in terms of
expected trigger rates and trigger efficiencies for different night-sky
background conditions are presented, and the camera response is compared to
end-to-end simulations.Comment: All CTA contributions at arXiv:1709.0348
Development of a strategy for calibrating the novel SiPM camera of the SST-1M telescope proposed for the Cherenkov Telescope Array
CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the
southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with
9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the
requirements of the next generation ground based gamma-ray observatory CTA in
the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of
gamma-ray telescopes can achieve good performance even during high night sky
background conditions. Defining a fully automated calibration strategy of SiPM
cameras is of great importance for large scale production validation and online
calibration. The SST-1M sub-consortium developed a software compatible with CTA
pipeline software (CTApipe). The calibration of the SST-1M camera is based on
the Camera Test Setup (CTS), a set of LED boards mounted in front of the
camera. The CTS LEDs are operated in pulsed or continuous mode to emulate
signal and night sky background respectively. Continuous and pulsed light data
analysis allows us to extract single pixel calibration parameters to be used
during CTA operation.Comment: All CTA contributions at arXiv:1709.0348
FlashCam: a fully-digital camera for the medium-sized telescopes of the Cherenkov Telescope Array
The FlashCam group is currently preparing photomultiplier-tube based cameras
proposed for the medium-sized telescopes (MST) of the Cherenkov Telescope Array
(CTA). The cameras are designed around the FlashCam readout concept which is
the first fully-digital readout system for Cherenkov cameras, based on
commercial FADCs and FPGAs as key components for the front-end electronics
modules and a high performance camera server as back-end. This contribution
describes the progress of the full-scale FlashCam camera prototype currently
under construction, as well as performance results also obtained with earlier
demonstrator setups. Plans towards the production and implementation of
FlashCams on site are also briefly presented.Comment: 8 pages, 6 figures. In Proceedings of the 34th International Cosmic
Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions
at arXiv:1508.0589
Performance Verification of the FlashCam Prototype Camera for the Cherenkov Telescope Array
The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is
planned to significantly improve upon the sensitivity and precision of the
current generation of Cherenkov telescopes. The observatory will consist of
several dozens of telescopes with different sizes and equipped with different
types of cameras. Of these, the FlashCam camera system is the first to
implement a fully digital signal processing chain which allows for a traceable,
configurable trigger scheme and flexible signal reconstruction. As of autumn
2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears
completion. First results of the ongoing system tests demonstrate that the
signal chain and the readout system surpass CTA requirements. The stability of
the system is shown using long-term temperature cycling.Comment: 5 pages, 13 figures, Proceedings of the 9th International Workshop on
Ring Imaging Cherenkov Detectors (RICH 2016), Lake Bled, Sloveni
- …