    Noise Reduction Using Singular Value Decomposition with Jensen–Shannon Divergence for Coronary Computed Tomography Angiography

    Get PDF
    Coronary computed tomography angiography (CCTA) is widely used due to its improvements in computed tomography (CT) diagnostic performance. Unlike other CT examinations, CCTA requires shorter rotation times of the X-ray tube, improving the temporal resolution and facilitating the imaging of the beating heart in a stationary state. However, reconstructed CT images, including those of the coronary arteries, contain insufficient X-ray photons and considerable noise. In this study, we introduce an image-processing technique for noise reduction using singular value decomposition (SVD) for CCTA images. The threshold of SVD was determined on the basis of minimization of Jensen–Shannon (JS) divergence. Experiments were performed with various numerical phantoms and varying levels of noise to reduce noise in clinical CCTA images using the determined threshold value. The numerical phantoms produced 10% higher-quality images than the conventional noise reduction method when compared on a quantitative SSIM basis. The threshold value determined by minimizing the JS–divergence was found to be useful for efficient noise reduction in actual clinical images, depending on the level of noise

    Tomographic Image Reconstruction Based on Minimization of Symmetrized Kullback-Leibler Divergence

    Get PDF
    Iterative reconstruction (IR) algorithms based on the principle of optimization are known for producing better reconstructed images in computed tomography. In this paper, we present an IR algorithm based on minimizing a symmetrized Kullback-Leibler divergence (SKLD) that is called Jeffreys’ J-divergence. The SKLD with iterative steps is guaranteed to decrease in convergence monotonically using a continuous dynamical method for consistent inverse problems. Specifically, we construct an autonomous differential equation for which the proposed iterative formula gives a first-order numerical discretization and demonstrate the stability of a desired solution using Lyapunov’s theorem. We describe a hybrid Euler method combined with additive and multiplicative calculus for constructing an effective and robust discretization method, thereby enabling us to obtain an approximate solution to the differential equation.We performed experiments and found that the IR algorithm derived from the hybrid discretization achieved high performance

    Two-step recrystallization of water in concentrated aqueous solution of poly(ethylene glycol).

    Get PDF
    Crystallization behavior of water in a concentrated aqueous solution of poly(ethylene glycol) (PEG) with a water content of 37.5 wt % was investigated by temperature variable mid-infrared (mid-IR) spectroscopy in a temperature range of 298-170 K. The mid-IR spectrum of water at 298 K showed that a large water cluster was not formed and that most of the water molecules were associated with the PEG chain. Ice formation, however, occurred as found in previous studies by differential scanning calorimetory. Ice formations were grouped into three types: crystallization at 231 K during cooling, that at 198 K during heating, and that at 210 K during heating. The latter two were just recrystallization. These ice formations were the direct transition from hydration species to ice without condensation regardless of crystallization or recrystallization. This means that the recrystallized water in the present system was not generated from low-density amorphous solid water. At a low cooling rate, nearly complete crystallization at 231 K during cooling and no recrystallization were observed. At a high cooling rate, no crystallization and two-step recrystallization at 198 and 210 K were observed. The former and latter recrystallizations were found to be generated from water associated with the PEG chains with ttg (the sequence -O-CH(2)-CH(2)-O- having a trans (t) conformation about the -C-O- bond and a gauche (g) conformation about the -C-C- bond) and random conformations, respectively. These results indicate that recrystallizable water does not have a single specific water structure

    Noise-Robust Image Reconstruction Based on Minimizing Extended Class of Power-Divergence Measures

    Get PDF
    The problem of tomographic image reconstruction can be reduced to an optimization problem of finding unknown pixel values subject to minimizing the difference between the measured and forward projections. Iterative image reconstruction algorithms provide significant improvements over transform methods in computed tomography. In this paper, we present an extended class of power-divergence measures (PDMs), which includes a large set of distance and relative entropy measures, and propose an iterative reconstruction algorithm based on the extended PDM (EPDM) as an objective function for the optimization strategy. For this purpose, we introduce a system of nonlinear differential equations whose Lyapunov function is equivalent to the EPDM. Then, we derive an iterative formula by multiplicative discretization of the continuous-time system. Since the parameterized EPDM family includes the Kullback–Leibler divergence, the resulting iterative algorithm is a natural extension of the maximum-likelihood expectation-maximization (MLEM) method. We conducted image reconstruction experiments using noisy projection data and found that the proposed algorithm outperformed MLEM and could reconstruct high-quality images that were robust to measured noise by properly selecting parameters

    Differences in image density adjustment parameters on the image matching accuracy of a floor-mounted kV X-ray image-guided radiation therapy system

    Get PDF
    This study aimed to investigate the effect of two different image density adjustment parameters on the results of image matching at six degrees of freedom using radiographic images generated by the ExacTrac X-ray system in brain stereotactic radiosurgery (SRS). This study comprised 32 patients who underwent brain SRS at our hospital from January 2020 to December 2020. In this study, (1) the default parameter (an image density parameter between “tissue” and “bone”) was an image density parameter for digitally reconstructed radiograph (DRR) generation used at many facilities, and (2) the bone parameter was the steepest contrast parameter used at our hospital. Of the 32 patients, 24 (75%) had a couch angle of 0.5 mm or more in the translational direction or 0.5° or more in the rotational direction, and 10 (31%) had a couch angle of 1.0 mm or more in the translational direction or 1.0° or more in the rotational direction. Among the 131 cases of all couch angles, 46 (35%) cases had a translational direction of 0.5 mm or more or a rotational direction of 0.5° or more, and 15 (11%) had a translational direction of 1.0 mm or more or a rotational direction of 1.0° or more. The results of this study indicate the usefulness of using appropriate DRR parameters for each case, rather than using the default settings. The use of appropriate DRR parameters can lead to accurate position matching results, leading to fewer image-guided radiation therapy shots and a lower imaging dose

    レミフェンタニル麻酔中の1%糖負荷が高齢者の代謝に与える影響 : 無作為対照比較試験

    Get PDF
    Background: Previous studies showed that remifentanil-induced anesthesia can inhibit surgical stress response in non-diabetic adult patients and that low-dose glucose loading during anesthesia may attenuate fat catabolism. However, little is known about the influence of glucose loading on metabolism in elderly patients, whose condition may be influenced by decreased basal metabolism and increased insulin resistance. We hypothesized that, in elderly patients, intraoperative low glucose infusion may attenuate the catabolism of fat without causing harmful hyperglycemia during remifentanil-induced anesthesia. Methods: Elderly, non-diabetic patients scheduled to undergo elective surgery were enrolled and randomized to receive no glucose (0G group) or low-dose glucose infusion (0.1 g/kg/hr. for 1 h followed by 0.05 g/kg/hr. for 1 h; LG group) during surgery. Glucose, adrenocorticotropic hormone (ACTH), 3-methylhistidine (3-MH), insulin, cortisol, free fatty acid (FFA), creatinine (Cr), and ketone body levels were measured pre-anesthesia, 1 h post-glucose infusion, at the end of surgery, and on the following morning. Results: A total of 31 patients (aged 75–85) were included (0G, n = 16; LG, n = 15). ACTH levels during anesthesia decreased significantly in both groups. In the LG group, glucose levels increased significantly after glucose loading but hyperglycemia was not observed. During surgery, ketone bodies and FFA were significantly lower in the LG group than the 0G group. There were no significant differences in insulin, Cr, 3-MH, and 3-MH/Cr between the two groups. Conclusion: Remifentanil-induced anesthesia inhibited surgical stress response in elderly patients. Intraoperative low-dose glucose infusion attenuated catabolism of fat without inducing hyperglycemia

    現行の口内法デジタルX線撮影システム間の薄い対象物及び厚い対象物におけるコントラストの違いの評価

    Get PDF
    The purpose is to evaluate the performance of current intraoral digital detectors in detail using a precise phantom and new method. Two aluminum step wedges in 0.5 mm steps were exposed by two photostimulable phosphor plate (PSP) systems—one with automatic exposure compensation (AEC) and the other without AEC—and a CCD sensor. Images were obtained with 3 doses at 60 kV. The effect of metallic material also was evaluated. The contrast-to-noise ratio (CNR) for thinner steps and the low contrast value (LCV) for thicker steps were obtained. The CCD system was the best under all conditions ( < 0.001), although the Gray value was sensitive to the dose, and the Gray value-dose relation varied greatly. The PSP system with AEC was superior to that without AEC for the LCV ( < 0.001) but was inferior to it regarding the CNR ( < 0.001). CNR and LCV in the PSP system without AEC were not affected by the metallic plate. Intraoral digital imaging systems should be chosen according to their diagnostic purpose. PSP system with AEC may be the best for detecting molar proximal caries, whereas the PSP system without AEC may be better for evaluating small bone regeneration in periodontal disease. The CCD system provided the best performance

    体育科における授業改善のための試行(1) : フィードバック情報の活用

    Get PDF
    本研究は,小学校の体育授業において,授業観察の結果で得られた情報を授業者にフィードバックし,それが次の授業実践の改善に向けてどのように機能しているかを確かめる事例的試行の第1報である。本論文は,教師の教授技能の一つである学習者との「相互作用」に着目し,授業中の教師(現職)の学習者に向けられた助言内容を量的・質的の両面から分析した結果の情報(フィードバック情報)が,次の授業実践においてどのように機能したかを授業記錦の定量的分析及び学習者の授業評価をもとに検証しようと試みたものである。その結果,教師の「肯定的言葉かけ」や「めあてのもたせ方」などに有効に機能していることがわかった。This study aimed to clarity how some informations from the resrlts of instructional observations effected to improve next instruction in physical education. Two instructions at primary school were chosen for this study. In this study, interaction between a teacher and learners was focused on as one of teaching skills. Through analysis of instructional observation, the interactions were picked up from the view points of qualitative and quantitative. And next, the results of former analysis were given to the teacher as informations (feedback information) for purposes of improving next instruction. From these analysis it was concluded that the feedback informations were useful for improving teacher\u27s positive talk and method to let learners know purposes