3 research outputs found

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    Get PDF
    Abstract Background This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p Conclusions In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH

    Real world data from a multi-centre study on the effects of cilostazol on pain symptoms and walking distance in patients with peripheral arterial disease

    No full text
    Objective: to assess the effects of cilostazol on pain-free walking distance in PAD patients with IC at 3 and 6 months in a real world, prospective, observational study. We included 1015 PAD patients presenting with IC (71.3% men, 93.5% white, mean age 69.2 ± 8.7 years). Patients were followed up for 6 months by their physicians. Results: Cilostazol significantly increased pain-free walking distance by a median of 285 and 387 m at 3 and 6 months, respectively (p < 0.01 for all comparisons). This effect was significant for patients 50–74 years (but not for those aged ≥ 75 years) and independent of smoking status, changes in physical activity, comorbidities and concomitant medication for PAD (i.e., acetylsalicylic acid and clopidogrel). Furthermore, significant reductions were observed in systolic (from 139 ± 16 to 133 ± 14 mmHg; p < 0.001) and diastolic blood pressure (from 84 ± 9 mmHg to 80 ± 10 mmHg; p < 0.001). Smoking cessation and increased physical activity were reported by the majority of participants. In conclusion, cilostazol was shown to safely decrease pain symptoms and improve pain-free walking in PAD patients with IC in a real world setting. Benefits also occurred in terms of BP and lifestyle changes. © 2022, The Author(s)

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    No full text
    Background: This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods: Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results: A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p &lt; 0.001). WCH phenomenon (high OBP with low HBP) was observed in 22.7% of the patients, MUCH (low OBP with high HBP) in 15.8%, uncontrolled hypertension (high OBP with high HBP) in 29.9%, and controlled hypertension (low OBP with low HBP) in 31.6%. In multivariate logistic regression analysis, WCH was determined by stage-1 systolic hypertension (odds ratio [OR] 8.6, 95% confidence intervals [CI] 5.7, 13.1) and female gender (OR 1.6, 95% CI 1.1, 2.4), whereas MUCH was determined by high-normal systolic OBP (OR 6.2, 95% CI 3.8, 10.1) and male gender (OR 2.0, 95% CI 1.2, 3.1). Conclusions: In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH. © 2019 Hellenic Society of Cardiolog
    corecore