    Caring for Blue-Green Solutions (BGS) in Everyday Life: An Investigation of Recreational Use, Neighborhood Preferences and Willingness to Pay in Augustenborg, Malmo

    Get PDF
    In this article, we explore the production of socio-cultural values around blue-green solutions (BGS) through the perspective of care. We explore how values and preferences are formed through the complexity of everyday life engagements in a BGS environment. The data come from a questionnaire answered by 328 households in the neighborhood of Augustenborg in Malmo, Sweden. The questionnaire collects detailed information about inhabitants' possible recreational use (through Likert scale questions) and willingness to pay (WTP) (estimated through contingent valuation). The study evaluates if and how people care to use, care to live with, and care to pay for BGS. The result shows that people in Augustenborg relate in different and sometimes contradictory ways to BGS. A well-used BGS environment does not per se make the environment successful or result in people preferring a BGS environment in the future. Building awareness about BGS seems to increase the willingness to pay, whereas recreational use seems to decrease it. The study reveals a landscape of care that is constantly being formed and transformed. This suggests that both planning and research needs to focus more on the relation between BGS and social use over time

    Coordinated and tailored work rehabilitation: a randomized controlled trial with economic evaluation undertaken with workers on sick leave due to musculoskeletal disorders

    Get PDF
    Introduction In Denmark, the magnitude and impact of work disability on the individual worker and society has prompted the development of a new "coordinated and tailored work rehabilitation" (CTWR) approach. The aim of this study was to compare the effects of CTWR with conventional case management (CCM) on return-to-work of workers on sick leave due to musculoskeletal disorders (MSDs). Methods The study was a randomized controlled trial with economic evaluation undertaken with workers on sick leave for 4-12 weeks due to MSDs. CTWR consists of a work disability screening by an interdisciplinary team followed by the collaborative development of a RTW plan. The primary outcome variable was registered cumulative sickness absence hours during 12 months follow-up. Secondary outcomes were work status as well as pain intensity and functional disability, measured at baseline, 3 and 12 months follow-up. The economic evaluation (intervention costs, productivity loss, and health care utilization costs) was based on administrative data derived from national registries. Results For the time intervals 0-6 months, 6-12 months, and the entire follow-up period, the number of sickness absence hours was significantly lower in the CTWR group as compared to the control group. The total costs saved in CTWR participants compared to controls were estimated at US 1,366perpersonat6monthsfollowāˆ’upandUS 1,366 per person at 6 months follow-up and US 10,666 per person at 12 months follow-up. Conclusions Workers on sick leave for 4-12 weeks due to MSD who underwent "CTWR" by an interdisciplinary team had fewer sickness absence hours than controls. The economic evaluation showed that-in terms of productivity loss-CTWR seems to be cost saving for the society

    Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty 163,368 hip replacements in the Nordic Arthroplasty Register Association database with 5-11 years of follow-up

    Get PDF
    Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis.Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups).Results - The CPE version of the ZCA cup had a risk of revision for any reason similar to that of the XLPE version (p = 0.09), but showed a 6-fold higher risk of revision for aseptic loosening (p < 0.001). The CPE version of the Reflection All Poly cup had an 8-fold elevated risk of revision for any reason (p < 0.001) and a 5-fold increased risk of revision for aseptic loosening (p < 0.001). The Charnley Elite Ogee/Marathon cup and the Trilogy cup did not show such differences.Interpretation Whether XLPE has any advantage over CPE regarding revision risk may depend on the properties of the polyethylene materials being compared, as well as the respective cup designs, fixation type, and follow-up times. Further research is needed to elucidate how cup design factors interact with polyethylene type to affect the risk of revision

    Total hip arthroplasties in the Dutch Arthroplasty Register (LROI) and the Nordic Arthroplasty Register Association (NARA): comparison of patient and procedure characteristics in 475,685 cases

    Get PDF
    Background and purpose - Collaborations between arthroplasty registries are important in order to create the possibility of detecting inferior implants early and improve our understanding of differences between nations in terms of indications and outcomes. In this registry study we compared patient and procedure characteristics, and revision rates in the Nordic Arthroplasty Register Association (NARA) database and the Dutch Arthroplasty Register (LROI).Patients and methods - All total hip arthroplasties (THAs) performed in 2010-2016 were included from the LROI (n = 184,862) and the NARA database (n = 290,823), which contains data from Denmark, Norway, Sweden, and Finland. Descriptive statistics and Kaplan-Meier survival analyses based on all reasons for revision and stratified by fixation were performed and compared between countries.Results - In the Netherlands, the proportion of patients aged < 55 years (9%) and male patients (34%) was lower than in Nordic countries (< 55 years 11-13%; males 35-43%); the proportion of osteoarthritis (OA) (87%) was higher compared with Sweden (81%), Norway (77%), and Denmark (81%) but comparable to Finland (86%). Uncemented fixation was used in 62% of patients in the Netherlands, in 70% of patients in Denmark and Finland, and in 28% and 19% in Norway and Sweden, respectively. The 5-year revision rate for THAs for OA was lower in Sweden (2.3%, 95% CI 2.1-2.5) than in the Netherlands (3.0%, CI 2.9-3.1), Norway (3.8%, CI 3.6-4.0), Denmark (4.6%, CI 4.4-4.8), and Finland (4.4%, CI 4.3-4.5). Revision rates in Denmark, Norway, and Finland were higher for all fixation groups.Interpretation - Patient and THA procedure characteristics as well as revision rates evinced some differences between the Netherlands and the Nordic countries. The Netherlands compared best with Denmark in terms of patient and procedure characteristics, but resembled Sweden more in terms of short-term revision risk. Combining data from registries like LROI and the NARA collaboration is feasible and might possibly enable tracking of potential outlier implants

    New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>This report presents a new imaging technique for non-invasive study of six degrees of freedom (DOF) knee kinematics during treadmill gait.</p> <p>Materials and methods</p> <p>A treadmill was integrated into a dual fluoroscopic imaging system (DFIS) to formulate a gait analysis system. To demonstrate the application of the system, a healthy subject walked on the treadmill at four different speeds (1.5, 2.0, 2.5 and 3.0 MPH) while the DFIS captured the knee motion during three strides under each speed. Characters of knee joint motion were analyzed in 6DOF during the treadmill walking.</p> <p>Results</p> <p>The speed of the knee motion was lower than that of the treadmill. Flexion amplitudes increased with increasing walking speed. Motion patterns in other DOF were not affected by increase in walking speed. The motion character was repeatable under each treadmill speed.</p> <p>Conclusion</p> <p>The presented technique can be used to accurately measure the 6DOF knee kinematics at normal walking speeds.</p
    • ā€¦
    corecore