288 research outputs found

    Multilocal fermionization

    Full text link
    We present a simple isomorphism between the algebra of one real chiral Fermi field and the algebra of n real chiral Fermi fields. This isomorphism preserves the vacuum state. This is possible by a "change of localization", and gives rise to new multilocal symmetries generated by the corresponding multilocal current and stress-energy tensor. The result gives a common underlying explanation of several remarkable recent results on the representation of the free Bose field in terms of free Fermi fields, and on the modular theory of the free Fermi algebra in disjoint intervals.Comment: 18 pages. v2: minor corrections, reference update

    Non-Anatomic Proximal Realignment for Recurrent Patellar Dislocation Does Not Sufficiently Prevent Redislocation

    Get PDF
    Several operative techniques have been described for recurrent patellar dislocation. Clinical results vary depending on the procedure and indication. The present study aimed to evaluate the clinical outcome of Insall’s proximal realignment for recurrent patellar dislocation at mid-term follow-up. Forty-five patients were reviewed with a mean follow-up period of 49 months after having undergone Insall’s procedure. Outcome measures included reports of redislocations, complications, patient-reported outcome scores (Kujala, Tegner activity scale) and subjective assessment. No statistically significant improvements (p < 0.05) in patient-reported outcome measures were noted. Sixteen patients (35%) had poor to fair results using the Kujala score. Subjective assessment revealed that 12 patients (27%) were dissatisfied with the outcome of their surgery and would not undergo the same procedure. Ten patients (22%) had suffered from redislocation at the latest follow-up. In 4 cases (9%), intra-articular knee hematoma occurred which required arthroscopic intervention. The overall mid-term outcome of the present study shows low patient satisfaction. Non-anatomic realignment for recurrent patellar dislocation does not adequately prevent redislocation

    Ultrafast electronic read-out of diamond NV centers coupled to graphene

    Get PDF
    Nonradiative transfer processes are often regarded as loss channels for an optical emitter1, since they are inherently difficult to be experimentally accessed. Recently, it has been shown that emitters, such as fluorophores and nitrogen vacancy centers in diamond, can exhibit a strong nonradiative energy transfer to graphene. So far, the energy of the transferred electronic excitations has been considered to be lost within the electron bath of the graphene. Here, we demonstrate that the trans-ferred excitations can be read-out by detecting corresponding currents with picosecond time resolution. We electrically detect the spin of nitrogen vacancy centers in diamond electronically and con-trol the nonradiative transfer to graphene by electron spin resonance. Our results open the avenue for incorporating nitrogen vacancy centers as spin qubits into ultrafast electronic circuits and for harvesting non-radiative transfer processes electronically

    Reproducibility of different screening classifications in ultrasonography of the newborn hip

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasonography of the hip has gained wide acceptance as a primary method for diagnosis, screening and treatment monitoring of developmental hip dysplasia in infants. The aim of the study was to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience.</p> <p>Methods</p> <p>In 207 consecutive newborns (101 boys; 106 girls) the following parameters were assessed: bony roof angle (α-angle) and cartilage roof angle (β-angle) according to Graf's basic standard method, "femoral head coverage" (FHC) as described by Terjesen, shape of the bony roof and position of the cartilaginous roof. Both hips were measured twice by each investigator with a 7.5 MHz linear transducer (SONOLINE G60S<sup>® </sup>ultrasound system, SIEMENS, Erlangen, Germany).</p> <p>Results</p> <p>Mean kappa-coefficients for the subjective parameters shape of the bony roof (0.97) and position of the cartilaginous roof (1.0) demonstrated high intra-observer reproducibility. Best results were achieved for α-angle, followed by β-angle and finally FHC. With respect to limits of agreement, inter-observer reproducibility was calculated less precisely.</p> <p>Conclusions</p> <p>Higher measurement differences were evaluated more in objective scorings. Those variations were observed by every investigator irrespective of level of experience.</p
    corecore