11 research outputs found

    Aerosol Generating Procedures and Risk of Transmission of Acute Respiratory Infections to Healthcare Workers: A Systematic Review

    Get PDF
    Aerosol generating procedures (AGPs) may expose health care workers (HCWs) to pathogens causing acute respiratory infections (ARIs), but the risk of transmission of ARIs from AGPs is not fully known. We sought to determine the clinical evidence for the risk of transmission of ARIs to HCWs caring for patients undergoing AGPs compared with the risk of transmission to HCWs caring for patients not undergoing AGPs. We searched PubMed, EMBASE, MEDLINE, CINAHL, the Cochrane Library, University of York CRD databases, EuroScan, LILACS, Indian Medlars, Index Medicus for SE Asia, international health technology agencies and the Internet in all languages for articles from 01/01/1990 to 22/10/2010. Independent reviewers screened abstracts using pre-defined criteria, obtained full-text articles, selected relevant studies, and abstracted data. Disagreements were resolved by consensus. The outcome of interest was risk of ARI transmission. The quality of evidence was rated using the GRADE system. We identified 5 case-control and 5 retrospective cohort studies which evaluated transmission of SARS to HCWs. Procedures reported to present an increased risk of transmission included [n; pooled OR(95%CI)] tracheal intubation [nβ€Š=β€Š4 cohort; 6.6 (2.3, 18.9), and nβ€Š=β€Š4 case-control; 6.6 (4.1, 10.6)], non-invasive ventilation [nβ€Š=β€Š2 cohort; OR 3.1(1.4, 6.8)], tracheotomy [nβ€Š=β€Š1 case-control; 4.2 (1.5, 11.5)] and manual ventilation before intubation [nβ€Š=β€Š1 cohort; OR 2.8 (1.3, 6.4)]. Other intubation associated procedures, endotracheal aspiration, suction of body fluids, bronchoscopy, nebulizer treatment, administration of O2, high flow O2, manipulation of O2 mask or BiPAP mask, defibrillation, chest compressions, insertion of nasogastric tube, and collection of sputum were not significant. Our findings suggest that some procedures potentially capable of generating aerosols have been associated with increased risk of SARS transmission to HCWs or were a risk factor for transmission, with the most consistent association across multiple studies identified with tracheal intubation

    Clinical effectiveness of rapid tests for methicillin resistant Staphylococcus aureus (MRSA) in hospitalized patients: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Methicillin resistant <it>Staphylococcus aureus </it>(MRSA) are often resistant to multiple classes of antibiotics. The research objectives of this systematic review were to evaluate the clinical effectiveness of polymerase chain reaction (PCR) versus chromogenic agar for MRSA screening, and PCR versus no screening for several clinical outcomes, including MRSA colonization and infection rates.</p> <p>Methods</p> <p>An electronic literature search was conducted on studies evaluating polymerase chain reaction techniques and methicillin (also spelled meticillin) resistant <it>Staphylococcus aureus </it>that were published from 1993 onwards using Medline, Medline In-Process & Other Non-Indexed Citations, BIOSIS Previews, and EMBASE. Due to the presence of heterogeneity in the selected studies, the clinical findings of individual studies were described.</p> <p>Results</p> <p>Nine studies that compared screening for MRSA using PCR versus screening using chromogenic agar in a hospital setting, and two studies that compared screening using PCR with no or targeted screening were identified. Some studies found lower MRSA colonization and acquisition, infection, and transmission rates in screening with PCR versus screening with chromogenic agar, and the turnaround time for screening test results was lower for PCR. One study reported a lower number of unnecessary isolation days with screening using PCR versus screening with chromogenic agar, but the proportion of patients isolated was similar between both groups. The turnaround time for test results and number of isolation days were lower for PCR versus chromogenic agar for MRSA screening.</p> <p>Conclusions</p> <p>The use of PCR for MRSA screening demonstrated a lower turnaround time and number of isolation days compared with chromogenic agar. Given the mixed quality and number of studies (11 studies), gaps remain in the published literature and the evidence remains insufficient. In addition to screening, factors such as the number of contacts between healthcare workers and patients, number of patients attended by one healthcare worker per day, probability of colonization among healthcare workers, and MRSA status of hospital shared equipment and hospital environment must be considered to control the transmission of MRSA in a hospital setting.</p

    Effectiveness of adverse effects search filters: drugs versus medical devices

    No full text
    Objective: The study tested the performance of adverse effects search filters when searching for safety information on medical devices, procedures, and diagnostic tests in MEDLINE and Embase. Methods: The sensitivity of 3 filters was determined using a sample of 631 references from 131 rapid reviews related to the safety of health technologies. The references were divided into 2 sets by type of intervention: drugs and nondrug health technologies. Keyword and indexing analysis were performed on references from the nondrug testing set that 1 or more of the filters did not retrieve. Results: For all 3 filters, sensitivity was lower for nondrug health technologies (ranging from 53%– 87%) than for drugs (88%–93%) in both databases. When tested on the nondrug health technologies set, sensitivity was lower in Embase (ranging from 53%–81%) than in MEDLINE (67%–87%) for all filters. Of the nondrug records that 1 or more of the filters missed, 39% of the missed MEDLINE records and 18% of the missed Embase records did not contain any indexing terms related to adverse events. Analyzing the titles and abstracts of nondrug records that were missed by any 1 filter, the most commonly used keywords related to adverse effects were: risk, complications, mortality, contamination, hemorrhage, and failure. Conclusions: In this study, adverse effects filters were less effective at finding information about the safety of medical devices, procedures, and tests compared to information about the safety of drugs

    Tracheal Intubation as Risk Factor of SARS Transmission.

    No full text
    <p>Tracheal Intubation as Risk Factor of SARS Transmission.</p

    Characteristics of included studies

    No full text
    <p>CoV: coronavirus; HCWs: health care workers; PCR: polymerase chain reaction; SARS: severe acute respiratory syndrome.</p
    corecore