7,378 research outputs found

    KIAA1114, a full-length protein encoded by the trophinin gene, is a novel surface marker for isolating tumor-initiating cells of multiple hepatocellular carcinoma subtypes

    Get PDF
    Identification of novel biomarkers for tumor-initiating cells (TICs) is of critical importance for developing diagnostic and therapeutic strategies against cancers. Here we identified the role of KIAA1114, a full-length translational product of the trophinin gene, as a distinctive marker for TICs in human liver cancer by developing a DNA vaccine-induced monoclonal antibody targeting the putative extracellular domain of KIAA1114. Compared with other established markers of liver TICs, KIAA1114 was unique in that its expression was detected in both alpha fetoprotein (AFP)-positive and AFP-negative hepatocellular carcinoma (HCC) cell lines with the expression levels of KIAA1114 being positively correlated to their tumorigenic potentials. Notably, KIAA1114 expression was strongly detected in primary hepatic tumor, but neither in the adjacent non-tumorous tissue from the same patient nor normal liver tissue. KIAA1114(high) cells isolated from HCC cell lines displayed TIC-like features with superior functional and phenotypic traits compared to their KIAA1114(low) counterparts, including tumorigenic abilities in xenotransplantation model, in vitro colony- and spheroid-forming capabilities, expression of stemness-associated genes, and migratory capacity. Our findings not only address the value of a novel antigen, KIAA1114, as a potential diagnostic factor of human liver cancer, but also as an independent biomarker for identifying TIC populations that could be broadly applied to the heterogeneous HCC subtypes.X1110Nsciescopu

    Response to imatinib rechallenge in a patient with a recurrent gastrointestinal stromal tumor after adjuvant therapy: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Adjuvant imatinib improves recurrence-free survival of patients following resection of primary KIT-positive gastrointestinal stromal tumors. However, it is unknown whether patients who previously received adjuvant imatinib therapy will respond to imatinib rechallenge as treatment for recurrent disease. Here we present the first report documenting the benefits of imatinib rechallenge in a patient previously exposed to imatinib during adjuvant treatment.</p> <p>Case presentation</p> <p>A 51-year-old Asian woman with a wedge-resected primary gastric gastrointestinal stromal tumor at high risk of relapse underwent two years of adjuvant treatment with imatinib. Only 10 months after the completion of adjuvant imatinib treatment, a computed tomography scan revealed gastrointestinal stromal tumor recurrence in this patient, with multiple peritoneal nodules in the upper abdomen being detected. Our patient was rechallenged with imatinib 400 mg/day and had a partial response after one month of treatment. Imatinib rechallenge was well tolerated by our patient; the only adverse events she experienced were grade 1 edema, anemia and fatigue. Our patient maintained a partial response two years and six months after the imatinib rechallenge. However, computed tomography scans three months later showed that our patient had disease progression.</p> <p>Conclusions</p> <p>This case report demonstrates that a patient with a gastrointestinal stromal tumor who had previously received adjuvant imatinib therapy responded to imatinib rechallenge as treatment for her recurrent disease. These results indicate that imatinib sensitivity can be maintained in a patient with previous exposure to adjuvant imatinib therapy.</p

    Simulation of the deflected cutting tool trajectory in complex surface milling

    Get PDF
    Since industry is rapidly developing, either locally or globally, manufacturers witness harder challenges due to the growing competitivity. This urges them to better consider the four factors linked to production and output: quality, quantity, cost and price, quality being of course the most important factor which constitutes their main concern. Efforts will be concentrated—in this research—on improving the quality and securing more accuracy for a machined surface in ball-end milling. Quality and precision are two essential criteria in industrial milling. However, milling errors and imperfections, duemainly to the cutting tool deflection, hinder the full achieving of these targets. Our task, all along this paper, consists in studying and realizing the simulation of the deflected cutting tool trajectory, by using the methods which are available. In a future stage, and in the frame of a deeper research, the simulation process will help to carry out the correction and the compensation of the errors resulting from the tool deflection. The corrected trajectory which is obtained by the method mirror will be sent to the machine. To achieve this goal, the next process consists—as a first step—in selecting a model of cutting forces for a ball-end mill. This allows to define—later on—the behavior of this tool, and the emergence of three methods namely the analytical model, the finite elements method, and the experimental method. It is possible to tackle the cutting forces simulation, all along the tool trajectory, while this latter is carrying out the sweeping of the part to be machined in milling and taking into consideration the cutting conditions, as well as the geography of the workpiece. A simulation of the deflected cutting tool trajectory dependent on the cutting forces has been realized

    Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology

    Get PDF
    Background: In the evaluation of upper limb impairment post stroke there remains a gap between detailed kinematic analyses with expensive motion capturing systems and common clinical assessment tests. In particular, although many clinical tests evaluate the performance of functional tasks, metrics to characterise upper limb kinematics are generally not applicable to such tasks and very limited in scope. This paper reports on a novel, user-friendly methodology that allows for the assessment of both signal magnitude and timing variability in upper limb movement trajectories during functional task performance. In order to demonstrate the technique, we report on a study in which the variability in timing and signal magnitude of data collected during the performance of two functional tasks is compared between a group of subjects with stroke and a group of individually matched control subjects. Methods: We employ dynamic time warping for curve registration to quantify two aspects of movement variability: 1) variability of the timing of the accelerometer signals' characteristics and 2) variability of the signals' magnitude. Six stroke patients and six matched controls performed several trials of a unilateral ('drinking') and a bilateral ('moving a plate') functional task on two different days, approximately 1 month apart. Group differences for the two variability metrics were investigated on both days. Results: For 'drinking from a glass' significant group differences were obtained on both days for the timing variability of the acceleration signals' characteristics (p = 0.002 and p = 0.008 for test and retest, respectively); all stroke patients showed increased signal timing variability as compared to their corresponding control subject. 'Moving a plate' provided less distinct group differences. Conclusion: This initial application establishes that movement variability metrics, as determined by our methodology, appear different in stroke patients as compared to matched controls during unilateral task performance ('drinking'). Use of a user-friendly, inexpensive accelerometer makes this methodology feasible for routine clinical evaluations. We are encouraged to perform larger studies to further investigate the metrics' usefulness when quantifying levels of impairment

    Intravaginal Administration of Fc-Fused IL7 Suppresses the Cervicovaginal Tumor by Recruiting HPV DNA Vaccine-Induced CD8 T Cells

    Get PDF
    Purpose: The induction of tissue-localized virus-specific CD8 T-cell response is essential for the development of an effective therapeutic vaccine against genital diseases, such as cervical cancer and genital herpes. Here, we aimed to elucidate the immunologic role of IL7 in the induction of mucosal cellular immunity. Experimental Design: IL7 was engineered through Fc fusion to enhance mucosal delivery across the genital epithelial barrier. The immunomodulatory role of IL7 was evaluated by monitoring the kinetics of various immune cells and measuring the expression of chemokines and cytokines after intravaginal administration of Fc-fused IL7 (IL7-Fc). The antitumor effects of intramuscular human papillomavirus (HPV) DNA vaccine or topical IL7-Fc alone or in a combinational regimen on mice survival were compared using a orthotopic cervical cancer model. Results: Intravaginal treatment of IL7-Fc, but not native IL7, induces upregulation of chemokines (CXCL10, CCL3, CCL4, and CCL5), cytokines (IFN-gamma, TNF alpha, IL6, and IL1 beta), and an adhesion molecule (VCAM-1) in the genital tract, leading to the recruitment of several leukocytes, including CD4, CD8, gamma delta T cells, and dendritic cells. Importantly, in this murine cervical cancer model, topical administration of IL7-Fc after intramuscular HPV DNA vaccination increases the number of HPV-specific CD8 T cells in the genital mucosa, but not in the spleen, leading to stronger antitumor activity than the HPV DNA vaccine alone. Conclusions: Our findings provide an important insight into the immunomodulatory role of IL7-Fc via topical application and the design of therapeutic vaccine regimen that induces effective genital-mucosal CD8 T-cell responses.1110Ysciescopu

    The Maximal U(1)LU(1)_L Inverse Seesaw from d=5d=5 Operator and Oscillating Asymmetric Sneutrino Dark Matter

    Get PDF
    The maximal U(1)LU(1)_L supersymmetric inverse seesaw mechanism (MLLSIS) provides a natural way to relate asymmetric dark matter (ADM) with neutrino physics. In this paper we point out that, MLLSIS is a natural outcome if one dynamically realizes the inverse seesaw mechanism in the next-to minimal supersymmetric standard model (NMSSM) via the dimension-five operator (N)2S2/M(N)^2S^2/M_*, with SS the NMSSM singlet developing TeV scale VEV; it slightly violates lepton number due to the suppression by the fundamental scale MM_*, thus preserving U(1)LU(1)_L maximally. The resulting sneutrino is a distinguishable ADM candidate, oscillating and favored to have weak scale mass. A fairly large annihilating cross section of such a heavy ADM is available due to the presence of singlet.Comment: journal versio

    Do mutual funds have consistency in their performance?

    Get PDF
    Using a comprehensive data set of 714 Chinese mutual funds from 2004 to 2015, the study investigates these funds’ performance persistence by using the Capital Asset Pricing model, the Fama-French three-factor model and the Carhart Four-factor model. For persistence analysis, we categorize mutual funds into eight octiles based on their one year lagged performance and then observe their performance for the subsequent 12 months. We also apply Cross-Product Ratio technique to assess the performance persistence in these Chinese funds. The study finds no significant evidence of persis- tence in the performance of the mutual funds. Winner (loser) funds do not continue to be winner (loser) funds in the subsequent time period. These findings suggest that future performance of funds cannot be predicted based on their past performance.info:eu-repo/semantics/publishedVersio

    What guidance are researchers given on how to present network meta-analyses to end-users such as policymakers and clinicians? A systematic review

    Get PDF
    © 2014 Sullivan et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Introduction: Network meta-analyses (NMAs) are complex methodological approaches that may be challenging for non-technical end-users, such as policymakers and clinicians, to understand. Consideration should be given to identifying optimal approaches to presenting NMAs that help clarify analyses. It is unclear what guidance researchers currently have on how to present and tailor NMAs to different end-users. Methods: A systematic review of NMA guidelines was conducted to identify guidance on how to present NMAs. Electronic databases and supplementary sources were searched for NMA guidelines. Presentation format details related to sample formats, target audiences, data sources, analysis methods and results were extracted and frequencies tabulated. Guideline quality was assessed following criteria developed for clinical practice guidelines. Results: Seven guidelines were included. Current guidelines focus on how to conduct NMAs but provide limited guidance to researchers on how to best present analyses to different end-users. None of the guidelines provided reporting templates. Few guidelines provided advice on tailoring presentations to different end-users, such as policymakers. Available guidance on presentation formats focused on evidence networks, characteristics of individual trials, comparisons between direct and indirect estimates and assumptions of heterogeneity and/or inconsistency. Some guidelines also provided examples of figures and tables that could be used to present information. Conclusions: Limited guidance exists for researchers on how best to present NMAs in an accessible format, especially for non-technical end-users such as policymakers and clinicians. NMA guidelines may require further integration with end-users' needs, when NMAs are used to support healthcare policy and practice decisions. Developing presentation formats that enhance understanding and accessibility of NMAs could also enhance the transparency and legitimacy of decisions informed by NMAs.The Canadian Institute of Health Research (CIHR) Drug Safety and Effectiveness Network (Funding reference number – 116573)
    corecore