1,224 research outputs found

    Performance Evaluation Factors Reflecting Player and Casting Judgments of Football Coaches

    Get PDF
    PURPOSE This study aimed to extract football coaches’ categories of performance evaluation factors (PEF) and examine the reflective characteristics of the football coaches’ player and casting judgments. METHODS PEF were extracted through an open-ended questionnaire and categorization from 80 AFC C or higher football coaches. Reflection was calculated in player and casting judgments through an analytic hierarchy process. The difference between the football coaches’ player and casting judgments was examined using SPSS 21.0. RESULTS First, the PEF of football coaches were categorized into four general categories: physical intelligence, psychological intelligence, growth potential, and competition intelligence. Second, the importance of football coaches’ player judgments were reflected by the PEF as football intelligence, situation judgment, football talent, tactical understanding, tactical operation, etc. The importance of the casting judgment were reflected by the PEF as tactical understanding, mediative skills, fitness, tactical operation, situation judgment, etc. Third, a statistically significant difference was noted between player and casting judgments. Football coaches tended to value growth potential and talent as sub-factors in the player evaluations. Football coaches’ PEF were aligned with the importance of player and casting judgments in psychological and competition intelligence as sub-factors such as skills, physical, attitude, passion, etc., but differed from physical intelligence and growth potential as sub-factors including mediative skills, physical, football talent, and tactical understanding. CONCLUSIONS In the football coaches’ player evaluations, the idealistic principle centered on growth potential. However, in the casting evaluation, the realistic principle centered on victory takes effect

    Spectrally narrowed edge emission from leaky waveguide modes in organic light-emitting diodes

    Get PDF
    A dramatic spectral line narrowing of the edge emission at room temperature from tris(quinolinolate) Al (Alq3), N,N′-diphenyl-N,N′-bis(1-naphthylphenyl)-1,1′-biphenyl-4,4′-diamine (NPD), 4,4′-bis(2,2′-diphenyl-vinyl)-,1′-biphenyl (DPVBi), and some guest-host small molecular organic light-emitting diodes(OLEDs), fabricated on indium tin oxide (ITO)-coated glass, is described. In all but the DPVBi OLEDs, the narrowed emission band emerges above a threshold thickness of the emitting layer, and narrows down to a full width at half maximum of only 5–10 nm. The results demonstrate that this narrowed emission is due to irregular waveguide modes that leak from the ITO to the glass substrate at a grazing angle. While measurements of variable stripe length l devices exhibit an apparent weak optical gain 0≤g≤1.86 cm−1, there is no observable threshold current or bias associated with this spectral narrowing. In addition, in the phosphorescent guest-host OLEDs, there is no decrease in the emission decay time of the narrowed edge emission relative to the broad surface emission. It is suspected that the apparent weak optical gain is due to misalignment of the axis of the waveguided mode and the axis of the collection lens of the probe. However, it is not clear if such a misalignment can account for all the effects of the observed evolution of the edge-emission spectra with l

    Effect of rhBMP-2 applied with a 3D-printed titanium implant on new bone formation in rabbit calvarium

    Get PDF
    Objective: This study sought to compare the biocompatibility of a three-dimensional (3D)-printed titanium implant with a conventional machined titanium product, as well as the effect of such implant applied with recombinant human Bone Morphogenetic Protein Type 2 (rhBMP-2) for guided bone regeneration. Methodology: Disk-shaped titanium specimens fabricated either by the conventional machining technique or by the 3D-printing technique were compared by MC3T3-E1 cells cytotoxicity assay. New bone formation was evaluated using a rapid prototype titanium cap applied to the calvaria of 10 rabbits, which were divided into two groups: one including an atelopeptide collagen plug on one side of the cap (group I) and the other including a plug with rhBMP-2 on the other side (group II). At six and 12 weeks after euthanasia, rabbits calvaria underwent morphometric analysis through radiological and histological examination. Results: Through the cytotoxicity assay, we identified a significantly higher number of MC3T3-E1 cells in the 3D-printed specimen when compared to the machined specimen after 48 hours of culture. Moreover, morphometric analysis indicated significantly greater bone formation at week 12 on the side where rhBMP-2 was applied when evaluating the upper portion immediately below the ca p. Conclusion: The results suggest that 3D-printed titanium implant applied with rhBMP-2 enables new bone formation

    Genetic diversity of Imjin virus in the Ussuri white-toothed shrew (Crocidura lasiura) in the Republic of Korea, 2004-2010

    Get PDF
    Recently, Imjin virus (MJNV), a genetically distinct hantavirus, was isolated from lung tissues of the Ussuri white-toothed shrew (Crocidura lasiura) captured near the demilitarized zone in the Republic of Korea. To clarify the genetic diversity of MJNV, partial M- and L-segment sequences were amplified from lung tissues of 12 of 37 (32.4%) anti-MJNV IgG antibody-positive Ussuri white-toothed shrews captured between 2004 and 2010. A 531-nucleotide region of the M segment (coordinates 2,255 to 2,785) revealed that the 12 MJNV strains differed by 0-12.2% and 0-2.3% at the nucleotide and amino acid levels, respectively. A similar degree of nucleotide (0.2-11.9%) and amino acid (0-3.8%) difference was found in a 632-nucleotide length of the L segment (coordinates 962 to 1,593) of nine MJNV strains. Phylogenetic analyses, based on the partial M and L segments of MJNV strains generated by the neighbor-joining and maximum likelihood methods, showed geographic-specific clustering, akin to the phylogeography of rodent-borne hantaviruses

    Surgical management of pilon fractures with large segmental bone defects using fibular strut allografts: a report of two cases

    Get PDF
    We present two patients with open pilon fractures with large bone defects treated successfully with fibular strut allografts. The patients were initially treated by massive irrigation, wound debridement, and temporary external fixation. After complete wound healing, the bone defects were managed. Because autologous iliac crest or fibular bone grafts were impossible to be harvested due to multiple fractures, the bone defects were reconstructed with fibular strut allografts. Fixation was performed with a periarticular distal tibia locking plate. At 2 months postoperatively, the patients ambulated with partial weight-bearing; at 6 months, they had full range of motion of the ankle joint and full weight-bearing

    Spectrally narrowed edge emission from organic light-emitting diodes

    Get PDF
    A dramatic spectrally narrowed edge emission (SNEE) from small molecular organic light-emitting diodes at room temperature, with a full width at half maximum of 5–10nm, is described. The results show that this emission is due to irregular waveguide modes that leak from the indium tin oxide anode to the glass substrate at a grazing angle. Measurements of variable stripe length devices exhibit an apparent weak optical gain, but there is no observable threshold bias associated with this SNEE. Hence this apparent “optical gain” is suspected to result from misalignment of the propagating leaky waveguide mode and the collecting optics

    Application of computer-aided diagnosis in breast ultrasound interpretation: improvements in diagnostic performance according to reader experience

    Get PDF
    Purpose The purpose of this study was to evaluate the usefulness of applying computer-aided diagnosis (CAD) to breast ultrasound (US), depending on the reader's experience with breast imaging. Methods Between October 2015 and January 2016, two experienced readers obtained and analyzed the grayscale US images of 200 cases according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon and categories. They additionally applied CAD (S-Detect) to analyze the lesions and made a diagnostic decision subjectively, based on grayscale US with CAD. For the same cases, two inexperienced readers analyzed the grayscale US images using the BI-RADS lexicon and categories, added CAD, and came to a subjective diagnostic conclusion. We then compared the diagnostic performance depending on the reader's experience with breast imaging. Results The sensitivity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 91.7%, 75.0%, 75.0%, and 66.7%, respectively. The specificity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 76.6%, 71.8%, 78.2%, and 76.1%, respectively. When diagnoses were made subjectively in combination with CAD, the specificity significantly improved (76.6% to 80.3%) without a change in the sensitivity (91.7%) in the experienced readers. After subjective combination with CAD, both of the sensitivity and specificity improved in the inexperienced readers (75.0% to 83.3% and 71.8% to 77.1%). In addition, the area under the curve improved for both the experienced and inexperienced readers (0.84 to 0.86 and 0.73 to 0.80) after the addition of CAD. Conclusion CAD is more useful for less experienced readers. Combining CAD with breast US led to improved specificity for both experienced and inexperienced readers
    • …
    corecore