1,844 research outputs found
Lateral distribution of electrons of air showers
The lateral distribution of electrons (LDE) of the air showers of size 10 to the 5th power to 10 to the 6th power was studied within one MU. It was found that the LDE of the air showers observed is well represented by NKG function except for vicinity of the core. It was also found that LDE measured by thin scintillators does not differ from that measured by thick ones of 50mm thickness
Transition effect of air shower particles in plastic scintillators
The transition effect of air shower particles in the plastic scintillators near the core was measured by scintillators of various thickness. The air showers selected for the measurement were of 10,000. Results obtained are as follows: (1) the multiplication of shower particles in the scintillators is less than 20% for that of 50 mm thickness; (2) dependence of the transition effect on age parameter is not recognized within the experimental errors
Character of energy flow in air shower core
Energy per charged particle near the core of air showers was measured by 9 energy flow detectors, which were the combination of Cerenkov counters and scintillators. Energy per particle of each detector was normalized to energy at 2m from the core. The following results were obtained as to the energy flow: (1) integral frequency distribution of mean energy per particle (averaged over 9 detectors) is composed of two groups separated distinctly; and (2) showers contained in one group show an anisotropy of arrival direction
Anodized aluminium pressure sensitive paint: effect of paint application technique
The porous surface of the Anodized Aluminium Pressure Sensitive Paint (AA-PSP) is what differentiates it from conventional sol–gel based PSPs, leading to a faster response time of the paint. The objective of the current study is to examine the effect of the paint application technique, i.e., whether the AA substrate is dipped or sprayed, on the pressure and temperature sensitivity. A more practical procedure for preparing the AA samples is also presented. Scanning Electron Microscope (SEM) images are acquired together with the calibration of the AA-PSP at various temperatures and pressures to determine the effectiveness of each application technique. The results revealed that the AA sample which was dipped in the PSP solution shows a higher pressure sensitivity than the sprayed one. The SEMs show that spraying leads to the covering up of the micropores created on the surface and undermining the benefit of anodization
Highly c-axis-oriented AlN film using MOCVD for 5GHz-band FBAR filter
科研費報告書収録論文(課題番号:14205053/研究代表者:坪内和夫/ソフトウェア無線端末用超低消費電力GHz帯RF DSPの開発
EVALUATION OF EXHAUST GAS FROM BIO-DIESEL FUEL ENGINE
Joint Research on Environmental Science and Technology for the Eart
Ground-state electric quadrupole moment of 31Al
Ground-state electric quadrupole moment of 31Al (I =5/2+, T_1/2 = 644(25) ms)
has been measured by means of the beta-NMR spectroscopy using a spin-polarized
31Al beam produced in the projectile fragmentation reaction. The obtained Q
moment, |Q_exp(31Al)| = 112(32)emb, are in agreement with conventional shell
model calculations within the sd valence space. Previous result on the magnetic
moment also supports the validity of the sd model in this isotope, and thus it
is concluded that 31Al is located outside of the island of inversion.Comment: 5 page
Variations of the cephalic vein anterior to the clavicle in humans
Background: Clinicians should understand that jugulocephalic vein (JCV) variants may be occasionally found. This study aims to classify JCV variants and obtain their frequency.
Materials and methods: We investigated anatomical variants of the cephalic vein in 55 human cadavers during a gross anatomy course at our medical school.
Results: The percentage of JCVs that pass through the anterior part of the clavicle and anastomose to the jugular vein as per previous studies and our study was 2–5%. Five cases with anastomosis between the cephalic and external jugular veins that pass through the anterior part of the clavicle were found. The courses were classified into 1A, 1B, 2A, and 2B. Type 1 extends beyond the clavicle and anastomoses with the external jugular vein. Type 2 follows the same course as type 1, but anastomoses with the subclavian vein. Subtype A does not have a branch that anastomoses with the axillary vein, whereas subtype B does. We encountered two cases of type 1A and three of type 1B.
Conclusions: Four anatomical variants of the cephalic vein around the clavicle were identified. Clinicians’ knowledge of these variants is expected to decrease possible complications if venous access via the cephalic vein is needed
- …