12 research outputs found

    Stability research on a natural circulation driven SCWR

    Get PDF

    Immunomonitoring of Tacrolimus in Healthy Volunteers: The First Step from PK- to PD-Based Therapeutic Drug Monitoring?

    Get PDF
    Therapeutic drug monitoring is routinely performed to maintain optimal tacrolimus concentrations in kidney transplant recipients. Nonetheless, toxicity and rejection still occur within an acceptable concentration-range. To have a better understanding of the relationship between tacrolimus dose, tacrolimus concentration, and its effect on the target cell, we developed functional immune tests for the quantification of the tacrolimus effect. Twelve healthy volunteers received a single dose of tacrolimus, after which intracellular and whole blood tacrolimus concentrations were measured and were related to T cell functionality. A significant correlation was found between tacrolimus concentrations in T cells and whole blood concentrations (r = 0.71, p = 0.009), while no correlation was found between tacrolimus concentrations in peripheral blood mononuclear cells (PBMCs) and whole blood (r = 0.35, p = 0.27). Phytohemagglutinin (PHA) induced the production of IL-2 and IFNγ, as well as the inhibition of CD71 and CD154 expression on T cells at 1.5 h post-dose, when maximum tacrolimus levels were observed. Moreover, the in vitro tacrolimus effect of the mentioned markers corresponded with the ex vivo effect after dosing. In conclusion, our results showed that intracellular tacrolimus concentrations mimic whole blood concentrations, and that PHA-induced cytokine production (IL-2 and IFNγ) and activation marker expression (CD71 and CD154) are suitable readout measures to measure the immunosuppressive effect of tacrolimus on the T cell

    Clinical validation of digital biomarkers for paediatric patients with asthma and cystic fibrosis:potential for clinical trials and clinical care

    Get PDF
    BACKGROUND: Digital biomarkers are a promising novel method to capture clinical data in a home setting. However, clinical validation prior to implementation is of vital importance. The aim of this study was to clinically validate physical activity, heart rate, sleep and forced expiratory volume in 1 s (FEV1) as digital biomarkers measured by a smartwatch and portable spirometer in children with asthma and cystic fibrosis (CF). METHODS: This was a prospective cohort study including 60 children with asthma and 30 children with CF (aged 6-16 years). Participants wore a smartwatch, performed daily spirometry at home and completed a daily symptom questionnaire for 28 days. Physical activity, heart rate, sleep and FEV1 were considered candidate digital end-points. Data from 128 healthy children were used for comparison. Reported outcomes were compliance, difference between patients and controls, correlation with disease activity, and potential to detect clinical events. Analysis was performed with linear mixed effects models. RESULTS: Median compliance was 88%. On average, patients exhibited lower physical activity and FEV1 compared with healthy children, whereas the heart rate of children with asthma was higher compared with healthy children. Days with a higher symptom score were associated with lower physical activity for children with uncontrolled asthma and CF. Furthermore, FEV1 was lower and (nocturnal) heart rate was higher for both patient groups on days with more symptoms. Candidate biomarkers appeared able to describe a pulmonary exacerbation. CONCLUSIONS: Portable spirometer- and smartwatch-derived digital biomarkers show promise as candidate end-points for use in clinical trials or clinical care in paediatric lung disease

    Effects of erythropoietin on cycling performance of well trained cyclists: a double-blind, randomised, placebo-controlled trial

    No full text
    Background Substances that potentially enhance performance (eg, recombinant human erythropoietin [rHuEPO]) are considered doping and are therefore forbidden in sports; however, the scientific evidence behind doping is frequently weak. We aimed to determine the effects of rHuEPO treatment in well trained cyclists on maximal, submaximal, and race performance and on safety, and to present a model clinical study for doping research on other substances. Methods We did this double-blind, randomised, placebo-controlled trial at the Centre for Human Drug Research in Leiden (Netherlands). We enrolled healthy, well trained but non-professional male cyclists aged 18–50 years and randomly allocated (1:1) them to receive abdominal subcutaneous injections of rHuEPO (epoetin β mean dose 6000 IU per week) or placebo (0·9% NaCl) for 8 weeks. Randomisation was stratified by age groups (18–34 years and 35–50 years), with a code generated by a statistician who was not masked to the study. The primary outcome was exercise performance, measured as maximal power output (Pmax), maximal oxygen consumption VO2 max, and gross efficiency in maximal exercise tests with 25 W increments per 5 min, as lactate threshold and ventilatory threshold 1 (VT1) and 2 (VT2) at submaximal levels during the maximal exercise test, and as mean power, VO2, and heart rate in the submaximal exercise tests at the highest mean power output for 45 min in a laboratory setting and in a race to the Mont Ventoux (France) summit, using intention-to-treat analyses. The trial is registered with the Dutch Trial Registry (Nederlands Trial Register), number NTR5643. Findings Between March 7, 2016, and April 13, 2016, we randomly assigned 48 participants to the rHuEPO group (n=24) or the placebo group (n=24). Mean haemoglobin concentration (9·6 mmol/L vs 9·0 mmol/L [estimated difference 0·6, 95% CI 0·4 to 0·8]) and maximal power output (351·55 W vs 341·23 W [10·32, 3·47 to 17·17]), and VO2 max (60·121 mL/min per kg vs 57·415 mL/min per kg [2·707, 0·911 to 4·503]) in a maximal exercise test were higher in the rHuEPO group compared with the placebo group. Submaximal exercise test parameters mean power output (283·18 W vs 277·28 W [5·90, −0·87 to 12·67]) and VO2 (50·288 mL/min per kg vs 49·642 mL/min per kg [0·646, −1·307 to 2·600]) at day 46, and Mont Ventoux race times (1 h 40 min 32 s vs 1 h 40 min 15 s [0·3%, −8·3 to 9·6]) did not differ between groups. All adverse events were grade 1–2 and were similar between both groups. No events of grade 3 or worse were observed. Interpretation Although rHuEPO treatment improved a laboratory test of maximal exercise, the more clinically relevant submaximal exercise test performance and road race performance were not affected. This study shows that clinical studies with doping substances can be done adequately and safely and are relevant in determining effects of alleged performance-enhancing drugs. Funding Centre for Human Drug Research, Leiden

    Hyperon signatures in the PANDA experiment at FAIR

    No full text
    We present a detailed simulation study of the signatures from the sequential decays of the triple-strange pbar p -> Ω+Ω- -> K+ΛbarK- Λ -> K+pbarπ+K-pπ- process in the PANDA central tracking system with focus on hit patterns and precise time measurement. We present a systematic approach for studying physics channels at the detector level and develop input criteria for tracking algorithms and trigger lines. Finally, we study the beam momentum dependence on the reconstruction efficiency for the PANDA detector

    Weaning from mechanical ventilation in intensive care units across 50 countries (WEAN SAFE): a multicentre, prospective, observational cohort study

    No full text
    Background Current management practices and outcomes in weaning from invasive mechanical ventilation are poorly understood. We aimed to describe the epidemiology, management, timings, risk for failure, and outcomes of weaning in patients requiring at least 2 days of invasive mechanical ventilation. Methods WEAN SAFE was an international, multicentre, prospective, observational cohort study done in 481 intensive care units in 50 countries. Eligible participants were older than 16 years, admitted to a participating intensive care unit, and receiving mechanical ventilation for 2 calendar days or longer. We defined weaning initiation as the first attempt to separate a patient from the ventilator, successful weaning as no reintubation or death within 7 days of extubation, and weaning eligibility criteria based on positive end-expiratory pressure, fractional concentration of oxygen in inspired air, and vasopressors. The primary outcome was the proportion of patients successfully weaned at 90 days. Key secondary outcomes included weaning duration, timing of weaning events, factors associated with weaning delay and weaning failure, and hospital outcomes. This study is registered with ClinicalTrials.gov, NCT03255109. Findings Between Oct 4, 2017, and June 25, 2018, 10 232 patients were screened for eligibility, of whom 5869 were enrolled. 4523 (77·1%) patients underwent at least one separation attempt and 3817 (65·0%) patients were successfully weaned from ventilation at day 90. 237 (4·0%) patients were transferred before any separation attempt, 153 (2·6%) were transferred after at least one separation attempt and not successfully weaned, and 1662 (28·3%) died while invasively ventilated. The median time from fulfilling weaning eligibility criteria to first separation attempt was 1 day (IQR 0–4), and 1013 (22·4%) patients had a delay in initiating first separation of 5 or more days. Of the 4523 (77·1%) patients with separation attempts, 2927 (64·7%) had a short wean (≤1 day), 457 (10·1%) had intermediate weaning (2–6 days), 433 (9·6%) required prolonged weaning (≥7 days), and 706 (15·6%) had weaning failure. Higher sedation scores were independently associated with delayed initiation of weaning. Delayed initiation of weaning and higher sedation scores were independently associated with weaning failure. 1742 (31·8%) of 5479 patients died in the intensive care unit and 2095 (38·3%) of 5465 patients died in hospital. Interpretation In critically ill patients receiving at least 2 days of invasive mechanical ventilation, only 65% were weaned at 90 days. A better understanding of factors that delay the weaning process, such as delays in weaning initiation or excessive sedation levels, might improve weaning success rates
    corecore