839 research outputs found

    Interplay between Nitrogen Dopants and Native Point Defects in Graphene

    Full text link
    To understand the interaction between nitrogen dopants and native point defects in graphene, we have studied the energetic stability of N-doped graphene with vacancies and Stone-Wales (SW) defect by performing the density functional theory calculations. Our results show that N substitution energetically prefers to occur at the carbon atoms near the defects, especially for those sites with larger bond shortening, indicating that the defect-induced strain plays an important role in the stability of N dopants in defective graphene. In the presence of monovacancy, the most stable position for N dopant is the pyridinelike configuration, while for other point defects studied (SW defect and divacancies) N prefers a site in the pentagonal ring. The effect of native point defects on N dopants is quite strong: While the N doping is endothermic in defect-free graphene, it becomes exothermic for defective graphene. Our results imply that the native point defect and N dopant attract each other, i.e., cooperative effect, which means that substitutional N dopants would increase the probability of point defect generation and vice versa. Our findings are supported by recent experimental studies on the N doping of graphene. Furthermore we point out possibilities of aggregation of multiple N dopants near native point defects. Finally we make brief comments on the effect of Fe adsorption on the stability of N dopant aggregation.Comment: 10 pages, 5 figures. Figure 4(g) and Figure 5 are corrected. One additional table is added. This is the final version for publicatio

    Computer-aided diagnosis system for osteoporosis based on quantitative evaluation of mandibular lower border porosity using panoramic radiographs

    Get PDF
    Objectives: A new computer-aided screening system for osteoporosis using panoramic radiographs was developed. The conventional system could detect porotic changes within the lower border of the mandible, but its severity could not be evaluated. Our aim was to enable the system to measure severity by implementing a linear bone resorption severity index (BRSI) based on the cortical bone shape. Methods: The participants were 68 females (>50 years) who underwent panoramic radiography and lumbar spine bone density measurements. The new system was designed to extract the lower border of the mandible as region of interests and convert them into morphological skeleton line images. The total perimeter length of the skeleton lines was defined as the BRSI. 40 images were visually evaluated for the presence of cortical bone porosity. The correlation between visual evaluation and BRSI of the participants, and the optimal threshold value of BRSI for new system were investigated through a receiver operator characteristic analysis. The diagnostic performance of the new system was evaluated by comparing the results from new system and lumbar bone density tests using 28 participants. Results: BRSI and lumbar bone density showed a strong negative correlation (p < 0.01). BRSI showed a strong correlation with visual evaluation. The new system showed high diagnostic efficacy with sensitivity of 90.9%, specificity of 64.7%, and accuracy of 75.0%. Conclusions: The new screening system is able to quantitatively evaluate mandibular cortical porosity. This allows for preventive screening for osteoporosis thereby enhancing clinical prospects

    Pickoff and spin-conversion quenchings of ortho-positronium in oxygen

    Get PDF
    The quenching processes of the thermalized ortho-positronium(o-Ps) on an oxygen molecule have been studied by the positron annihilation age-momentum correlation techinique(AMOC). The Doppler broadening spectrum of the 511 keV gamma-rays from the 2gamma annihilation of o-Ps in O_2 has been measured as a function of the o-Ps age. The rate of the quenching, consisting of the pickoff and the spin-conversion, is estimated from the positron lifetime spectrum. The ratio of the pickoff quenching rate to the spin-conversion rate is deduced from the Doppler broadening of the 511 keV gamma-rays from the annihilation of the o-Ps. The pickoff parameter ^1Z_eff, the effective number of the electrons per molecule which contribute to the pickoff quenching, for O_2 is determined to be 0.6 +- 0.4. The cross-section for the elastic spin-conversion quenching is determined to be (1.16 +- 0.01) * 10^{-19} cm^2.Comment: 4 pages with 5 eps figures, LaTeX2e(revtex4

    Prognostic factors for lymph node metastasis from upper gingival carcinomas

    Get PDF
    This study sought to identify tumor characteristics that associate with regional lymph node metastases in squamous cell carcinomas originating in the upper gingiva

    Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments

    Get PDF
    Most of the Ultra High Energy Cosmic Ray (UHECR) experiments and projects (HiRes, AUGER, TA, EUSO, TUS,...) use air fluorescence to detect and measure extensive air showers (EAS). The precise knowledge of the Fluorescence Light Yield (FLY) is of paramount importance for the reconstruction of UHECR. The MACFLY - Measurement of Air Cherenkov and Fluorescence Light Yield - experiment has been designed to perform such FLY measurements. In this paper we will present the results of FLY in the 290-440 nm wavelength range for dry air and pure nitrogen, both excited by electrons with energy of 1.5 MeV, 20 GeV and 50 GeV. The experiment uses a 90Sr radioactive source for low energy measurement and a CERN SPS electron beam for high energy. We find that the FLY is proportional to the deposited energy (E_d) in the gas and we show that the air fluorescence properties remain constant independently of the electron energy. At the reference point: atmospheric dry air at 1013 hPa and 23C, the ratio FLY/E_d=17.6 photon/MeV with a systematic error of 13.2%.Comment: 19 pages, 8 figures. Accepted for publication in Astroparticle Physic

    Change of temporomandibular joint disk configuration and clinical findings following conservative treatment

    Get PDF
    The objective of this study was to evaluate the relationship between changes in the disk status (position and reduction) and changes in the clinical findings following conservative temporomandibular joint(TMJ) treatment. The subjects consisted of 164 patients (328 joints) having TMJ disorders. Clinical examination and MR imaging were performed on all patients before and after conservative treatment. Clinical assessments included joint noise, pain and inter-incisal distance(IID). Disk position and reduction was classified as "improved", "worsened", or "unchanged" following treatment. In the 55 joints where disk position was improved, noise was improved in 37(67.2%) and worsened in 6(10.9%). In the 48 joints where disk reduction was improved, noise was improved in 34(70.8%) and worsened in 4(8.3%). There was a significant relationship between improvement in the disk status and improvement in the noise. In 55 joins where the disk position was improved, pain symptoms were disappeared in 22(40.0%) and newly occured in 4(7.3%). In the 56 joins where the pain was disappeared, disk reduction improved in 22(39.3%), but became worse in 22(39.3%) joints. In 56 joints where the pain was disappeared, disk reduction improved in 17(30.4%) joints disk reduction improved in 17(30.4%) joins but became worse in 32(57%). There was no significant relationship between improvement in the disk status and improvement in the pain. Treatment has no significant influence on IID. We conclude that there was no relationship between improvement in the disk status and improvement in the joint pain and IID after conservative treatment, but there was close relationship between disk stutus and the joint noise in their changes

    Very High Energy Gamma Rays from PSR1706-44

    Full text link
    We have obtained evidence of gamma-ray emission above 1 TeV from PSR1706-44, using a ground-based telescope of the atmospheric \v{C}erenkov imaging type located near Woomera, South Australia. This object, a Îł\gamma-ray source discovered by the COS B satellite (2CG342-02), was identified with the radio pulsar through the discovery of a 102 ms pulsed signal with the EGRET instrument of the Compton Gamma Ray Observatory. The flux of the present observation above a threshold of 1 TeV is ∌\bf \sim 1 ⋅\cdot 10−11^{-11} photons cm−2^{-2} s−1^{-1}, which is two orders of magnitude smaller than the extrapolation from GeV energies. The analysis is not restricted to a search for emission modulated with the 102 ms period, and the reported flux is for all Îł\gamma-rays from PSR1706-44, pulsed and unpulsed. The energy output in the TeV region corresponds to about 10−3^{-3} of the spin down energy loss rate of the neutron star.Comment: 13 pages, latex format (article), 2 figures include

    T2 relaxation times of the retrodiscal tissue in patients with temporomandibular joint disorders and in healthy volunteers: A comparative study

    Get PDF
    Objective. The aims of this study were to compare the temporomandibular joint (TMJ) retrodiscal tissue T2 relaxation times between patients with temporomandibular disorders (TMDs) and asymptomatic volunteers and to assess the diagnostic potential of this approach. Study Design. Patients with TMD (n = 173) and asymptomatic volunteers (n = 17) were examined by using a 1.5-T magnetic resonance scanner. The imaging protocol consisted of oblique sagittal, T2-weighted, 8-echo fast spin echo sequences in the closed mouth position. Retrodiscal tissue T2 relaxation times were obtained. Additionally, disc location and reduction, disc configuration, joint effusion, osteoarthritis, and bone edema or osteonecrosis were classified using MRI scans. The T2 relaxation times of each group were statistically compared. Results. Retrodiscal tissue T2 relaxation times were significantly longer in patient groups than in asymptomatic volunteers (P < .01). T2 relaxation times were significantly longer in all of the morphologic categories. The most important variables affecting retrodiscal tissue T2 relaxation times were disc configuration, joint effusion, and osteoarthritis. Conclusion. Retrodiscal tissue T2 relaxation times of patients with TMD were significantly longer than those of healthy volunteers. This finding may lead to the development of a diagnostic marker to aid in the early detection of TMDs
    • 

    corecore