95 research outputs found

    An Adversarial Approach to Structural Estimation

    Full text link
    We propose a new simulation-based estimation method, adversarial estimation, for structural models. The estimator is formulated as the solution to a minimax problem between a generator (which generates synthetic observations using the structural model) and a discriminator (which classifies if an observation is synthetic). The discriminator maximizes the accuracy of its classification while the generator minimizes it. We show that, with a sufficiently rich discriminator, the adversarial estimator attains parametric efficiency under correct specification and the parametric rate under misspecification. We advocate the use of a neural network as a discriminator that can exploit adaptivity properties and attain fast rates of convergence. We apply our method to the elderly's saving decision model and show that including gender and health profiles in the discriminator uncovers the bequest motive as an important source of saving across the wealth distribution, not only for the rich.Comment: 58 pages, 3 tables, 4 figure

    A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

    Get PDF
    CO2 refrigerant is expected to be use for air conditioners due to its environmental property of GWP = 1, non-flammability and low toxicity and has already been applied to hot water supply system, refrigerators and freezers. However, since cycle COP of CO2 is poorer than that of HFC in applying to air conditioner, it cannot be expected to improve the performance significantly by simply improving the efficiency of a conventional single-stage cycle and components consisting of the cycle.  Therefore, it is important to improve the cycle efficiency, especially in the performance of cooling which is a weak point of CO2. Challenges also lie in reducing weight of components such as compressor and heat exchangers resulted in weight gain to resist high pressure and to achieve high efficiency in the system. In this study, a prototype of CO2 refrigerant VRF air conditioning system is constructed and evaluates the performance. The system is adopting the four-stage compression cycle applying a new type compressor and heat exchangers and so on aimed for high efficiency cycle and reducing weight As a result of the evaluation, it is confirmed that CO2 cycle performance can be improved in similar extent to HFC refrigerant cycle. On the other hand, this high efficiency cycle consists of a lot of components and becomes more complex than HFC refrigerant cycle; therefore the size and weight of outdoor unit increases to house these components. Further technical development will be necessary to overcome these weaknesses

    ALS clinically presenting with PMA

    Get PDF
    Amyotrophic lateral sclerosis (ALS) primarily affects upper and lower motor neurons. Phosphorylated TAR DNA-binding protein of 43 kDa (TDP-43) inclusion bodies are reportedly a pathological hallmark of sporadic ALS. Here, we present an atypical case of sporadic ALS that progressed very slowly, persisted for 19 years, and clinically appeared to only affect the lower motor neurons; however, upper motor neuron degeneration was detected on autopsy. Furthermore, no inclusion bodies positive for phosphorylated TDP-43, ubiquitin, fused in sarcoma, or SOD1 were detected in the CNS. We performed exome-sequencing data analysis but found no genetic disorders. This was therefore an unusual case of lower motor neuron-predominant ALS without TDP-43 pathology or known gene-disease associations. We also reviewed autopsied ALS cases that progressed slowly and had no phosphorylated TDP-43 or ubiquitin positive inclusions and present the clinicopathological features of such cases. Based on these results, there may be a sporadic ALS subgroup that progresses slowly and shows 76 no accumulation of phosphorylated TDP-43

    Can Pallidal Deep Brain Stimulation Rescue Borderline Dystonia? Possible Coexistence of Functional (Psychogenic) and Organic Components

    Get PDF
    The diagnosis and treatment of functional movement disorders are challenging for clinicians who manage patients with movement disorders. The borderline between functional and organic dystonia is often ambiguous. Patients with functional dystonia are poor responders to pallidal deep brain stimulation (DBS) and are not good candidates for DBS surgery. Thus, if patients with medically refractory dystonia have functional features, they are usually left untreated with DBS surgery. In order to investigate the outcome of functional dystonia in response to pallidal DBS surgery, we retrospectively included five patients with this condition. Their dystonia was diagnosed as organic by dystonia specialists and also as functional according to the Fahn and Williams criteria or the Gupta and Lang Proposed Revisions. Microelectrode recordings in the globus pallidus internus of all patients showed a cell-firing pattern of bursting with interburst intervals, which is considered typical of organic dystonia. Although their clinical course after DBS surgery was incongruent to organic dystonia, the outcome was good. Our results question the possibility to clearly differentiate functional dystonia from organic dystonia. We hypothesized that functional dystonia can coexist with organic dystonia, and that medically intractable dystonia with combined functional and organic features can be successfully treated by DBS surgery

    Reliability of DWI and FLAIR for diagnosis of sporadic CJD

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldte–Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Multicentre multiobserver study of diffusion-weighted and fluid-attenuated inversion recovery MRI for the diagnosis of sporadic Creutzfeldt–Jakob disease: a reliability and agreement study

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Gait and posture assessments of a patient treated with deep brain stimulation in dystonia using three-dimensional motion analysis systems

    Get PDF
    Kinesiologic analysis of gait disorders, postural instabilities and abnormal movements is quite difficult to assess objectively by clinical observation, such as by specific scale and video recordings. In this study, we reported one of the aspects of the usefulness of three-dimensional motion analysis (Vicon Systems, Oxford, United Kingdom), which can measure inclusive data of movement disorders and substitute for conventional assessments. A 49-year-old man who had various dystonic symptoms, mainly on his left side of the body, responded well to deep brain stimulation (DBS). The examination quantified how the involuntary movements or other symptoms with dystonia changed before and after treatments
    corecore