1,229 research outputs found

    AROS Is a Significant Biomarker for Tumor Aggressiveness in Non-cirrhotic Hepatocellular Carcinoma

    Get PDF
    Despite a low risk of liver failure and preserved liver function, non-cirrhotic hepatocellular carcinoma (HCC) has a poor prognosis. In the current study, we evaluated an active regulator of SIRT1 (AROS) as a prognostic biomarker in non-cirrhotic HCC. mRNA levels of AROS were measured in tumor and non-tumor tissues obtained from 283 non-cirrhotic HCC patients. AROS expression was exclusively up-regulated in recurrent tissues from the non-cirrhotic HCC patients (P = 0.015) and also in tumor tissues irrespective of tumor stage (P < 0.001) or BCLC stage (P < 0.001). High mRNA levels of AROS were statistically significantly associated with tumor stage (P < 0.001), BCLC stage (P = 0.007), alpha fetoprotein (AFP) level (P = 0.013), microvascular invasion (P = 0.001), tumor size (P = 0.036), and portal vein invasion (P = 0.005). Kaplan-Meir curve analysis demonstrated that HCC patients with higher AROS levels had shorter disease-free survival (DFS) in both the short-term (P < 0.001) and long-term (P = 0.005) compared to those with low AROS. Cox regression analysis demonstrated that AROS is a significant predictor for DFS along with large tumor size, tumor multiplicity, vascular invasion, and poor tumor differentiation, which are the known prognostic factors. In conclusion, AROS is a significant biomarker for tumor aggressiveness in non-cirrhotic hepatocellular carcinoma.1122Ysciescopu

    Reduced length of hospital stay in colorectal surgery after implementation of an enhanced recovery protocol.

    Get PDF
    BACKGROUND: Enhanced recovery after surgery (ERAS) is a multimodal approach to perioperative care that combines a range of interventions to enable early mobilization and feeding after surgery. We investigated the feasibility, clinical effectiveness, and cost savings of an ERAS program at a major U. S. teaching hospital. METHODS: Data were collected from consecutive patients undergoing open or laparoscopic colorectal surgery during 2 time periods, before and after implementation of an ERAS protocol. Data collected included patient demographics, operative, and perioperative surgical and anesthesia data, need for analgesics, complications, inpatient medical costs, and 30-day readmission rates. RESULTS: There were 99 patients in the traditional care group, and 142 in the ERAS group. The median length of stay (LOS) was 5 days in the ERAS group compared with 7 days in the traditional group (P < 0.001). The reduction in LOS was significant for both open procedures (median 6 vs 7 days, P = 0.01), and laparoscopic procedures (4 vs 6 days, P < 0.0001). ERAS patients had fewer urinary tract infections (13% vs 24%, P = 0.03). Readmission rates were lower in ERAS patients (9.8% vs 20.2%, P = 0.02). DISCUSSION: Implementation of an enhanced recovery protocol for colorectal surgery at a tertiary medical center was associated with a significantly reduced LOS and incidence of urinary tract infection. This is consistent with that of other studies in the literature and suggests that enhanced recovery programs could be implemented successfully and should be considered in U.S. hospitals

    Robust Bounds on Choosing from Large Tournaments

    Full text link
    Tournament solutions provide methods for selecting the "best" alternatives from a tournament and have found applications in a wide range of areas. Previous work has shown that several well-known tournament solutions almost never rule out any alternative in large random tournaments. Nevertheless, all analytical results thus far have assumed a rigid probabilistic model, in which either a tournament is chosen uniformly at random, or there is a linear order of alternatives and the orientation of all edges in the tournament is chosen with the same probabilities according to the linear order. In this work, we consider a significantly more general model where the orientation of different edges can be chosen with different probabilities. We show that a number of common tournament solutions, including the top cycle and the uncovered set, are still unlikely to rule out any alternative under this model. This corresponds to natural graph-theoretic conditions such as irreducibility of the tournament. In addition, we provide tight asymptotic bounds on the boundary of the probability range for which the tournament solutions select all alternatives with high probability.Comment: Appears in the 14th Conference on Web and Internet Economics (WINE), 201

    Self-activated ultrahigh chemosensitivity of oxide thin film nanostructures for transparent sensors

    Get PDF
    One of the top design priorities for semiconductor chemical sensors is developing simple, low-cost, sensitive and reliable sensors to be built in handheld devices. However, the need to implement heating elements in sensor devices, and the resulting high power consumption, remains a major obstacle for the realization of miniaturized and integrated chemoresistive thin film sensors based on metal oxides. Here we demonstrate structurally simple but extremely efficient all oxide chemoresistive sensors with similar to 90% transmittance at visible wavelengths. Highly effective self-activation in anisotropically self-assembled nanocolumnar tungsten oxide thin films on glass substrate with indium-tin oxide electrodes enables ultrahigh response to nitrogen dioxide and volatile organic compounds with detection limits down to parts per trillion levels and power consumption less than 0.2 microwatts. Beyond the sensing performance, high transparency at visible wavelengths creates opportunities for their use in transparent electronic circuitry and optoelectronic devices with avenues for further functional convergence.open181

    Design of Experiments for Screening

    Full text link
    The aim of this paper is to review methods of designing screening experiments, ranging from designs originally developed for physical experiments to those especially tailored to experiments on numerical models. The strengths and weaknesses of the various designs for screening variables in numerical models are discussed. First, classes of factorial designs for experiments to estimate main effects and interactions through a linear statistical model are described, specifically regular and nonregular fractional factorial designs, supersaturated designs and systematic fractional replicate designs. Generic issues of aliasing, bias and cancellation of factorial effects are discussed. Second, group screening experiments are considered including factorial group screening and sequential bifurcation. Third, random sampling plans are discussed including Latin hypercube sampling and sampling plans to estimate elementary effects. Fourth, a variety of modelling methods commonly employed with screening designs are briefly described. Finally, a novel study demonstrates six screening methods on two frequently-used exemplars, and their performances are compared

    Spiral ligament fibrocyte-derived MCP-1/CCL2 contributes to inner ear inflammation secondary to nontypeable H. influenzae-induced otitis media

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Otitis media (OM), one of the most common pediatric infectious diseases, causes inner ear inflammation resulting in vertigo and sensorineural hearing loss. Previously, we showed that spiral ligament fibrocytes (SLFs) recognize OM pathogens and up-regulate chemokines. Here, we aim to determine a key molecule derived from SLFs, contributing to OM-induced inner ear inflammation.</p> <p>Methods</p> <p>Live NTHI was injected into the murine middle ear through the tympanic membrane, and histological analysis was performed after harvesting the temporal bones. Migration assays were conducted using the conditioned medium of NTHI-exposed SLFs with and without inhibition of MCP-1/CCL2 and CCR2. qRT-PCR analysis was performed to demonstrate a compensatory up-regulation of alternative genes induced by the targeting of MCP-1/CCL2 or CCR2.</p> <p>Results</p> <p>Transtympanic inoculation of live NTHI developed serous and purulent labyrinthitis after clearance of OM. THP-1 cells actively migrated and invaded the extracellular matrix in response to the conditioned medium of NTHI-exposed SLFs. This migratory activity was markedly inhibited by the viral CC chemokine inhibitor and the deficiency of MCP-1/CCL2, indicating that MCP-1/CCL2 is a main attractant of THP-1 cells among the SLF-derived molecules. We further demonstrated that CCR2 deficiency inhibits migration of monocyte-like cells in response to NTHI-induced SLF-derived molecules. Immunolabeling showed an increase in MCP-1/CCL2 expression in the cochlear lateral wall of the NTHI-inoculated group. Contrary to the <it>in vitro </it>data, deficiency of MCP-1/CCL2 or CCR2 did not inhibit OM-induced inner ear inflammation <it>in vivo</it>. We demonstrated that targeting MCP-1/CCL2 enhances NTHI-induced up-regulation of MCP-2/CCL8 in SLFs and up-regulates the basal expression of CCR2 in the splenocytes. We also found that targeting CCR2 enhances NTHI-induced up-regulation of MCP-1/CCL2 in SLFs.</p> <p>Conclusions</p> <p>Taken together, we suggest that NTHI-induced SLF-derived MCP-1/CCL2 is a key molecule contributing to inner ear inflammation through CCR2-mediated recruitment of monocytes. However, deficiency of MCP-1/CCL2 or CCR2 alone was limited to inhibit OM-induced inner ear inflammation due to compensation of alternative genes.</p

    Biodegradable, flexible silicon nanomembrane-based NO x gas sensor system with record-high performance for transient environmental monitors and medical implants

    Get PDF
    Abstract: A novel transient electronics technology that is capable of completely dissolving or decomposing in certain conditions after a period of operation offers unprecedented opportunities for medical implants, environmental sensors, and other applications. Here, we describe a biodegradable, flexible silicon-based electronic system that detects NO species with a record-breaking sensitivity of 136 Rs (5 ppm, NO2) and 100-fold selectivity for NO species over other substances with a fast response (~30 s) and recovery (~60 s). The exceptional features primarily depend on not only materials, dimensions, and design layouts but also temperatures and electrical operations. Large-scale sensor arrays in a mechanically pliable configuration exhibit negligible deterioration in performance under various modes of applied loads, consistent with mechanics modeling. In vitro evaluations demonstrate the capability and stability of integrated NOx devices in severe wet environments for biomedical applications

    Single Mode Lasing from Hybrid Hemispherical Microresonators

    Get PDF
    Enormous attention has been paid to optical microresonators which hold a great promise for microlasers as well as fundamental studies in cavity quantum electrodynamics. Here we demonstrate a three-dimensional (3D) hybrid microresonator combining self-assembled hemispherical structure with a planar reflector. By incorporating dye molecules into the hemisphere, optically pumped lasing phenomenon is observed at room temperature. We have studied the lasing behaviors with different cavity sizes, and particularly single longitudinal mode lasing from hemispheres with diameter ∼15 μm is achieved. Detailed characterizations indicate that the lasing modes shift under varying pump densities, which can be well-explained by frequency shift and mode hopping. This work provides a versatile approach for 3D confined microresonators and opens an opportunity to realize tunable single mode microlasers

    Abnormal septal convexity into the left ventricle occurs in subclinical hypertrophic cardiomyopathy.

    Get PDF
    BACKGROUND: Sarcomeric gene mutations cause hypertrophic cardiomyopathy (HCM). In gene mutation carriers without left ventricular (LV) hypertrophy (G + LVH-), subclinical imaging biomarkers are recognized as predictors of overt HCM, consisting of anterior mitral valve leaflet elongation, myocardial crypts, hyperdynamic LV ejection fraction, and abnormal apical trabeculation. Reverse curvature of the interventricular septum (into the LV) is characteristic of overt HCM. We aimed to assess LV septal convexity in subclinical HCM. METHODS: Cardiovascular magnetic resonance was performed on 36 G + LVH- individuals (31 ± 14 years, 33 % males) with a pathogenic sarcomere mutation, and 36 sex and age-matched healthy controls (33 ± 12 years, 33 % males). Septal convexity (SCx) was measured in the apical four chamber view perpendicular to a reference line connecting the mid-septal wall at tricuspid valve insertion level and the apical right ventricular insertion point. RESULTS: Septal convexity was increased in G + LVH- compared to controls (maximal distance of endocardium to reference line: 5.0 ± 2.5 mm vs. 1.6 ± 2.4 mm, p ≤ 0.0001). Expected findings occurred in G + LVH- individuals: longer anterior mitral valve leaflet (23.5 ± 3.0 mm vs. 19.9 ± 3.1 mm, p ≤ 0.0001), higher relative wall thickness (0.31 ± 0.05 vs. 0.29 ± 0.04, p ≤ 0.05), higher LV ejection fraction (70.8 ± 4.3 % vs. 68.3 ± 4.4 %, p ≤ 0.05), and smaller LV end-systolic volume index (21.4 ± 4.4 ml/m(2) vs. 23.7 ± 5.8 ml/m(2), p ≤ 0.05). Other morphologic measurements (LV angles, sphericity index, and eccentricity index) were not different between G + LVH- and controls. CONCLUSIONS: Septal convexity is an additional previously undescribed feature of subclinical HCM
    corecore