5,428 research outputs found
Monolithic Ge:Ga Detector Development for SAFARI
We describe the current status and the prospect for the development of
monolithic Ge:Ga array detector for SAFARI. Our goal is to develop a 64x64
array for the 45 -- 110 um band, on the basis of existing technologies to make
3x20 monolithic arrays for the AKARI satellite. For the AKARI detector we have
achieved a responsivity of 10 A/W and a read-out noise limited NEP (noise
equivalent power) of 10^-17 W/rHz. We plan to develop the detector for SAFARI
with technical improvements; significantly reduced read-out noise with newly
developed cold read-out electronics, mitigated spectral fringes as well as
optical cross-talks with a multi-layer antireflection coat. Since most of the
elemental technologies to fabricate the detector are flight-proven, high
technical readiness levels (TRLs) should be achieved for fabricating the
detector with the above mentioned technical demonstrations. We demonstrate some
of these elemental technologies showing results of measurements for test
coatings and prototype arrays.Comment: To appear in Proc. Workshop "The Space Infrared Telescope for
Cosmology & Astrophysics: Revealing the Origins of Planets and Galaxies".
Eds. A.M. Heras, B. Swinyard, K. Isaak, and J.R. Goicoeche
Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
<p>Abstract</p> <p>Introduction</p> <p>We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism.</p> <p>Case presentation</p> <p>A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed.</p> <p>Conclusion</p> <p>Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.</p
Measurement Of Transverse Instability Thresholds In Low And high Emittance optics At The Photon Factory Storage Ring
Study of the spectral properties of ELM precursors by means of wavelets
The high confinement regime (H-mode) in tokamaks is accompanied by the occurrence of bursts of MHD activity at the plasma edge, so-called edge localized modes (ELMs), lasting less than 1 ms. These modes are often preceded by coherent oscillations in the magnetic field, the ELM precursors, whose mode numbers along the toroidal and the poloidal directions can be measured from the phase shift between Mirnov pickup coils. When the ELM precursors have a lifetime shorter than a few milliseconds, their toroidal mode number and their nonlinear evolution before the ELM crash cannot be studied reliably with standard techniques based on Fourier analysis, since averaging in time is implicit in the computation of the Fourier coefficients. This work demonstrates significant advantages in studying spectral features of the short-lived ELM precursors by using Morlet wavelets. It is shown that the wavelet analysis is suitable for the identification of the toroidal mode numbers of ELM precursors with the shortest lifetime, as well as for studying their nonlinear evolution with a time resolution comparable to the acquisition rate of the Mirnov coils
- …