10 research outputs found

    The morphology of the afferent and efferent domain of the sheep glomerulus

    Get PDF
    Background: It is important to know the morphology of the glomerulus in order to explain kidney infiltration. The present study aims to research the morphology of afferent and efferent domains of sheep kidney glomeruli. Materials and methods: In this study, 2000 glomeruli from 20 kidneys of Akkaraman sheep were examined using the polyester resin method. Results: It was found that the glomeruli of sheep kidney usually had an afferent arteriole as well as an efferent arteriole. Besides, it was also found that five glomeruli had two efferent arterioles. It is known that the afferent domain constitutes the largest part of the glomerulus. In two of the glomeruli that we examined, the afferent domain formed the 1/2 of the glomeruli wherein the other two glomeruli afferent domain formed the 3/4.Conclusions: It is known that there are many anastomoses between the afferent and efferent domain of capillaries. However, it is not well-explained how anastomosis is created between the afferent and efferent domains. In our study, it was identified that those anastomoses were not inside the lobes but between the surrounding capillaries

    An unique unilateral tendon variation of the extensor digitorum longus muscle

    Get PDF
    Purpose: The double tendon of extensor digitorum longus (EDL) muscle was observed on the left leg of a 80-year-old male cadaver. Methods: A male cadaver 80 years old was subjected to routine anatomical dissection for research and teaching purposes. Results: The main tendon of the EDL muscle started just at the end of the muscle belly. However, the accessory tendon started at the tendinous end of the muscle as a continuation of the muscle. The main and accessory tendons split into two more slips after passing through the same tunnel below the extensor retinaculum. There was also difference on ending of the tendon slips of EDL muscle. The main tendon divided into two tendinous slips on the dorsum of the foot attached to the second and third toes. The accessory tendon divided into two tendinous slips on the dorsum of the foot attached to the fourth and the fifth toes. Conclusion: Knowledge of the tendons and anatomical differences of this muscle is important for surgeons in interventional procedures involving the dorsum of the foot. © 2022, The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature

    A Comparison of Automated Segmentation and Manual Tracing of Magnetic Resonance Imaging to Quantify Lateral Ventricle Volumes

    Get PDF
    Objective: Ventricular volume measurements have been proposed as a useful biomarker for several neurological diseases. The goal of this study was to compare the performance of 3 fully-automated tools, volBrain (http://volbrain.upv.es), ALVIN (Automatic Lateral Ventricle Delineation) (https://sites.google.com/site/mrilateralventricle/), and MRICloud (http://mricloud.org), with expert hand tracing to quantify lateral ventricle (LV) volume using magnetic resonance images. Materials and Methods: The sample comprised 24 healthy subjects (age: 25.1±5.7 years, all male). Volumes derived from each automated measurement were compared to hand tracing results performed by 2 specialists to assess the percent volume difference using the intraclass correlation coefficient (ICC), concordance correlation coefficient (CCC), Dice index value, and Bland-Altman analysis. Results: The ICC agreement of the Manual_1 and Manual_2 was very good (0.979), and there was no statistically significant difference (p>0.001). The volume difference of all methods was similar. The CCC with MRICloud and ALVIN was higher than that of volBrain. Bland-Altman plots indicated that the 3 automated methods demonstrated acceptable agreement. Conclusion: Compared with hand tracing, the LV volumes generated by MRICloud were more accurate than those of volBrain and ALVIN. LV volume values can provide valuable data related to the volumetric dependencies of the anatomical structures in various clinical conditions that can now be easily obtained using automated tools

    GNSS station design for global climate change monitoring in Antarctica: ınstallation of TUR1 and TUR2 GNSS stations on Horseshoe Island in Antarctica During The 4th Turkish Antarctic Science Expedition

    Get PDF
    Son yıllarda uzay tabanlı konumlama sistemleri, GNSS Meteorolojisi ve GNSS Reflektometresi teknikleri kullanılarak gözlemlenen atmosferik su buharı, deniz, buz ve kar seviyeleri gibi önemli parametrelerle küresel iklim değişikliğinin izlenmesinde etkili bir destekleyici araç haline gelmiştir. Küresel ölçekte tüm bölgelerden daha hızlı ısınan Antarktika'da iklim değişikliğini incelemek, gelecekteki iklim değişikliğini daha doğru tahmin etmek için çok önemlidir. Dünya'nın iklim değişikliği etkilerinin izlenebilmesi amacıyla, 118Y322 No’lu TÜBİTAK projesi kapsamında GNSS Meteorolojisi ve GNSS Reflektometresi teknikleri ile 24 Şubat 2020 tarihinden itibaren Antarktika’da atmosferik su buharı değişimleri, kar derinliği ve buz kalınlığı değişimleri gözlemlenmektedir. Bu çalışmada, Troposfer ve Deniz Seviyesi Gözlem İstasyonu (TUR1) ile Troposfer ve Kar / Buz Seviyesi Gözlem İstasyonunun (TUR2) tasarım çalışmaları ve 4. Ulusal Antarktika Bilim Seferi’nde Antarktika Horseshoe Adası’na kurulum aşamaları anlatılmıştır. Bu çalışmalar, meteorolojik koşullar, şebekeden bağımsız ve batarya ile bütünleşik enerji sisteminin en sağlıklı şekilde güneş ve rüzgâr enerjisinden beslenmesi ve bölgede oluşabilecek buzul oluşumu ve kayaç parçalanması gibi jeolojik parametreler de göz önüne alınarak yapılmıştır.In recent years, space-based positioning systems have become an effective supporting tool for monitoring global climate change by important parameters such as atmospheric water vapor, sea, ice and snow levels observed by using GNSS Meteorology and GNSS Reflectometry techniques. Studying climate change in Antarctica, which is warming faster than all of the regions on a global scale, is very important to predict future climate change more accurately. In order to monitor climate change effects of the Earth, tropospheric water vapor variations, snow depth and ice thickness changes have been observing in Antarctica since 24 February 2020 by means of GNSS Meteorology and GNSS Reflectometry techniques within the scope of the TUBITAK Project No. 118Y322 In this study, designing studies of Troposphere and Sea Level Observation Station (TUR1) and Troposphere and Snow / Ice Level Observation Station (TUR2) and installation steps to Horseshoe Island in Antarctica during the 4th National Antarctic Science Expedition are explained. These studies was carried out by taking into account the meteorological conditions, the healthiest feeding of the off grid battery integrated energy system from solar and wind energy and geological parameters such as glacial formation and rock fragmentation that may occur in the region

    A golden ratio for foramen magnum: an anatomical pilot study

    Get PDF
    Background: The foramen magnum (FM) is an important landmark because of its close relationship to key structures such as the brainstem and spinal cord, an extension of the medulla oblongata. Because of the similarity in their shape, the existence of a relationship between cranial length and anteroposterior diameter of the FM, and between cranial width and transverse diameter of the FM may reveal the magnificent harmony of the skull and FM. Based on this idea, we investigated the existence of this harmony in skulls that we used in our study. Materials and methods: In this study, 60 adult dry skulls belonging to the Turkish population were examined. The anteroposterior and transverse diameters of the foramen magnum and the length and width of the skull were measured. Measurements were made directly on the skull using a digital sliding calliper. New indices and ratios were applied with those measurements.Results: Our study suggests that FM width and FM length could be estimated by using the cranial length and cranial width measurements in the skull by accepting the mean of these coefficients (4.62) as the golden ratio. The average of the coefficients of cranial width to FM width ratio (4.62 ± 0.35 [95% CI: 4.52–4.70]) and the average of the coefficients of cranial length to the FM length ratio (4.62 ± 0.50 [95% CI: 4.49–4.76]) were found to be equal to each other. In order to check the accuracy of this hypothesis, FM width and FM lengths were estimated with the help of new equations.Conclusions: In the present study, the ratio between the anteroposterior and transverse diameters of both FM and the cranium was estimated at 4.62, indicating a magnificent harmony between cranial and subcranial structures. Withthis ratio, it is easy to estimate FM’s size based on simple cranial measurements. (Folia Morphol 2022; 81, 1: 220–226

    A new supportive approach in the diagnosis of Chiari malformation type 1 in pediatric patients

    No full text
    © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.Purpose: Chiari malformation type 1 (CM-1) is a posterior fossa anomaly characterized by herniation of the cerebellar tonsils from the foramen magnum (FM). This study compares FM, medulla spinalis (MS), and herniated cerebellar tonsils ratios by making area measurements from axial plane MRI in CM-1 patients and the control group. Methods: Our study evaluated 30 pediatric patients with CM-1 and 30 people in the control group. The lengths of the McRae line, twining line, and clivus line were measured on the posterior cranial fossa evaluation. The areas of FM (AFM), MS (AMS), and herniated cerebellar tonsils (ATONSILS) were measured by axial images. Results: As a result of area measurements obtained from axial cross-sectional MRI, a statistically significant difference was found between CM-1 patients and the control group. According to the results of the ROC analysis, if an individual’s AMS/AFM value is above 17.9% or the ATONSILS/AFM value is above 18.4%, it can be interpreted as a CM-1 patient. Conclusion: It will be easier to diagnose the patient with the new approach we obtained from axial MR images in addition to sagittal MR images. This method can be a guide in some cases when the surgeons are undecided

    A Comparison of Automated Segmentation and Manual Tracing of Magnetic Resonance Imaging to Quantify Lateral Ventricle Volumes

    Get PDF
    Objective: Ventricular volume measurements have been proposed as a useful biomarker for several neurological diseases. The goal of this study was to compare the performance of 3 fully-automated tools, volBrain (http://volbrain.upv.es ), ALVIN (Automatic Lateral Ventricle Delineation) (https://sites.google.com/site/mrilateralventricle/), and MRICIoud (http://mricloud.org ), with expert hand tracing to quantify lateral ventricle (LV) volume using magnetic resonance images. Materials and Methods: The sample comprised 24 healthy subjects (age: 25.1 +/- 5.7 years, all male). Volumes derived from each automated measurement were compared to hand tracing results performed by 2 specialists to assess the percent volume difference using the intraclass correlation coefficient (ICC), concordance correlation coefficient (CCC), Dice index value, and Bland-Altman analysis. Results: The ICC agreement of the Manual_1 and Manual_2 was very good (0.979), and there was no statistically significant difference (p>0.001). The volume difference of all methods was similar. The CCC with MRICloud and ALVIN was higher than that of volBrain. Bland-Altman plots indicated that the 3 automated methods demonstrated acceptable agreement. Conclusion: Compared with hand tracing, the LV volumes generated by MRICloud were more accurate than those of volBrain and ALVIN. LV volume values can provide valuable data related to the volumetric dependencies of the anatomical structures in various clinical conditions that can now be easily obtained using automated tools
    corecore