2,037 research outputs found

    Quantitative information flow, with a view

    Get PDF
    We put forward a general model intended for assessment of system security against passive eavesdroppers, both quantitatively ( how much information is leaked) and qualitatively ( what properties are leaked). To this purpose, we extend information hiding systems ( ihs ), a model where the secret-observable relation is represented as a noisy channel, with views : basically, partitions of the state-space. Given a view W and n independent observations of the system, one is interested in the probability that a Bayesian adversary wrongly predicts the class of W the underlying secret belongs to. We offer results that allow one to easily characterise the behaviour of this error probability as a function of the number of observations, in terms of the channel matrices defining the ihs and the view W . In particular, we provide expressions for the limit value as n → ∞, show by tight bounds that convergence is exponential, and also characterise the rate of convergence to predefined error thresholds. We then show a few instances of statistical attacks that can be assessed by a direct application of our model: attacks against modular exponentiation that exploit timing leaks, against anonymity in mix-nets and against privacy in sparse datasets

    Metering Characteristics Accompanying Rate Changes Necessary for Precision Farming

    Get PDF
    Agricultural machines used in precision fanning must adjust application rates according to the needs of each cell within a field. Changing from an initial application rate to a new rate while the machine travels from one cell to another in the field is accompanied with some misapplication. The severity of this misapplication depends on the down-the-row delivery characteristics of the metering system and the magnitude of the rate change from cell to cell. On-the-go rate change tests evaluated the down-the-row performance of an operator controlled metering system when increasing and decreasing wheat seeding rates by 10 and 20 kg/ha steps. The transition time from one cell to another ranged from 3 to 9 s depending upon the magnitude of the application rate change. The difference between the initial and final seeding rate was based on a simple index. This separation index was based upon the initial and final down-the-row seeding rate distributions. When the separation index was greater than or equal to zero, the difference between the initial and final application rate was considered to be suitable for precision fanning. The separation criterion was always satisfied with 20 kg/ha rate changes. For 10 kg/ha rate changes, the separation index was negative in most cases. This indicated that rate changes of 10 kg/ha or less were unlikely to provide detectable rate differences as the metering rate variability exceeded the magnitude of the 10 kg/ha rate change

    Cholesterol, C-Reactive Protein, and Periodontitis: HMG-CoA-Reductase Inhibitors (Statins) as Effect Modifiers

    Get PDF
    Common risk factors of periodontitis and cardiovascular diseases fuel the debate on interrelationships between them. The aim is to prove whether statins may influence periodontal parameters by affecting either of these factors. Out of the 4,290 subjects of SHIP (Study of Health in Pomerania), we included subjects aged >30 years (219 with statins, 2937 without) and excluded edentulous. We determined periodontal measures, cholesterol fractions, and inflammation markers. Statin use and periodontal risk factors were assessed. Gingival plaque and periodontal attachment loss were associated with systemic LDL cholesterol (P < 0.001) and C-reactive protein CRP (P = 0.019) revealing interaction with statin use. When adjusted for age, sex, smoking, diabetes, education, and dental service, statins were identified as effect modifiers abolishing the relationship between attachment loss and LDL and between gingival plaque and LDL (interactions P < 0.001). No statin-related interaction was detected with increase in CRP. The interaction supports the view of inter-relationships between periodontal and systemic inflammatory mediators

    Metering Characteristics Accompanying Rate Changes Necessary for Precision Farming

    Get PDF
    Agricultural machines used in precision fanning must adjust application rates according to the needs of each cell within a field. Changing from an initial application rate to a new rate while the machine travels from one cell to another in the field is accompanied with some misapplication. The severity of this misapplication depends on the down-the-row delivery characteristics of the metering system and the magnitude of the rate change from cell to cell. On-the-go rate change tests evaluated the down-the-row performance of an operator controlled metering system when increasing and decreasing wheat seeding rates by 10 and 20 kg/ha steps. The transition time from one cell to another ranged from 3 to 9 s depending upon the magnitude of the application rate change. The difference between the initial and final seeding rate was based on a simple index. This separation index was based upon the initial and final down-the-row seeding rate distributions. When the separation index was greater than or equal to zero, the difference between the initial and final application rate was considered to be suitable for precision fanning. The separation criterion was always satisfied with 20 kg/ha rate changes. For 10 kg/ha rate changes, the separation index was negative in most cases. This indicated that rate changes of 10 kg/ha or less were unlikely to provide detectable rate differences as the metering rate variability exceeded the magnitude of the 10 kg/ha rate change

    Variability in Volume Metering Devices

    Get PDF
    The inherent variability of seed and fertilizer application from volumetric metering devices is not readily recognized. The Canadian Prairie Agricultural Machinery Institute (P AMI) suggests a maximum coefficient of variation (CV) of 15% among outlets for seeding grain or applying fertilizer. P AMI does not report down-the-row variability of individual outlets. Parameters that influence variability of volumetric measuring external fluted wheels such as rotational speed of the metering wheel, product delivery rate, seed size, and cell collection lengths were examined. In the first study, external fluted wheel meters on four grain drills were tested for seed delivery variability for wheat and soybeans, both among the metering outlets and down-the-row for individual meters. Tests on two additional drills, one an air drill and the other with external fluted metering, used two sizes of soybean seeds and two travel speeds. For wheat, down-the-row CV ranged from 12.5 to 22.5% and the CV among metering units ranged from 12.5 to 21 %. For soybeans, the CV ranged from 15.5 to 41.5% with the air drill having the lower CV. A faster travel speed gave a lower CV for both drills metering soybeans. In a second study, when metering wheat, the seeding rate variability due to cell size and seeding rate were evaluated. Each meter was evaluated with cells 0.48 or 0.96 m in length and seeding rates of 60, 80,90, and 100 kg/ha. The down-the-row CV ranged from 10 to 28% with 0.48 m length cells, and from 4 to 22% with 0.96 m length cells. Some of these CVs may be too high for a metering mechanism such as the fluted wheel to be used in SSCM

    Effect of Testing and Treatment on Emergency Department Length of Stay Using a National Database

    Full text link
    Objectives:  Testing and treatment are essential aspects of the delivery of emergency care. Recognition of the effects of these activities on emergency department (ED) length of stay (LOS) has implications for administrators planning efficient operations, providers, and patients regarding expectations for length of visit; researchers in creating better models to predict LOS; and policy‐makers concerned about ED crowding. Methods:  A secondary analysis was performed using years 2006 through 2008 of the National Hospital Ambulatory Medical Care Survey (NHAMCS), a nationwide study of ED services. In univariate and bivariate analyses, the authors assessed ED LOS and frequency of testing (blood test, urinalysis, electrocardiogram [ECG], radiograph, ultrasound, computed tomography [CT], or magnetic resonance imaging [MRI]) and treatment (providing a medication or performance of a procedure) according to disposition (discharged or admitted status). Two sets of multivariable models were developed to assess the contribution of testing and treatment to LOS, also stratified by disposition. The first was a series of logistic regression models to provide an overview of how testing and treatment activity affects three dichotomized LOS cutoffs at 2, 4, and 6 hours. The second was a generalized linear model (GLM) with a log‐link function and gamma distribution to fit skewed LOS data, which provided time costs associated with tests and treatment. Results:  Among 360 million weighted ED visits included in this analysis, 227 million (63%) involved testing, 304 million (85%) involved treatment, and 201 million (56%) involved both. Overall, visits with any testing were associated with longer LOS (median = 196 minutes; interquartile range [IQR] = 125 to 305 minutes) than those with any treatment (median = 159 minutes; IQR = 91 to 262 minutes). This difference was more pronounced among discharged patients than admitted patients. Obtaining a test was associated with an adjusted odds ratio (OR) of 2.29 (95% confidence interval [CI] = 1.86 to 2.83) for experiencing a more than 4‐hour LOS, while performing a treatment had no effect (adjusted OR = 0.84; 95% CI = 0.68 to 1.03). The most time‐costly testing modalities included blood test (adjusted marginal effects on LOS = +72 minutes; 95% CI = 66 to 78 minutes), MRI (+64 minutes; 95% CI = 36 to 93 minutes), CT (+59 minutes; 95% CI = 54 to 65 minutes), and ultrasound (US; +56 minutes; 95% CI = 45 to 67 minutes). Treatment time costs were less substantial: performing a procedure (+24 minutes; 95% CI = 20 to 28 minutes) and providing a medication (+15 minutes; 95% CI = 8 to 21 minutes). Conclusions:  Testing and less substantially treatment were associated with prolonged LOS in the ED, particularly for blood testing and advanced imaging. This knowledge may better direct efforts at streamlining delivery of care for the most time‐costly diagnostic modalities or suggest areas for future research into improving processes of care. Developing systems to improve efficient utilization of these services in the ED may improve patient and provider satisfaction. Such practice improvements could then be examined to determine their effects on ED crowding.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/92123/1/j.1553-2712.2012.01353.x.pd

    A Case Report on Longitudinal Collection of Tumour Biopsies for Gene Expression-Based Tumour Microenvironment Analysis from Pancreatic Cancer Patients Treated with Endoscopic Ultrasound Guided Radiofrequency Ablation.

    Get PDF
    BACKGROUND: Most patients with pancreatic ductal adenocarcinoma (PDAC) are metastatic at presentation with dismal prognosis warranting improved systemic therapy options. Longitudinal sampling for the assessment of treatment response poses a challenge for validating novel therapies. In this case study, we evaluate the feasibility of collecting endoscopic ultrasound (EUS)-guided longitudinal fine-needle aspiration biopsies (FNABs) from two PDAC patients and conduct gene expression studies associated with tumour microenvironment changes associated with radiofrequency ablation (RFA). METHODS: EUS-guided serial/longitudinal FNABs of tumour were collected before and after treatment from two stage III inoperable gemcitabine-treated PDAC patients treated with targeted RFA three times. Biopsies were analysed using a custom NanoString panel (144 genes) consisting of cancer and cancer-associated fibroblast (CAFs) subtypes and immune changes. CAF culture was established from one FNAB and characterised by immunofluorescence and immunoblotting. RESULTS: Two-course RFA led to the upregulation of the CD1E gene (involved in antigen presentation) in both patients 1 and 2 (4.5 and 3.9-fold changes) compared to baseline. Patient 1 showed increased T cell genes (CD4-8.7-fold change, CD8-35.7-fold change), cytolytic function (6.4-fold change) and inflammatory response (8-fold change). A greater than 2-fold upregulation of immune checkpoint genes was observed post-second RFA in both patients. Further, two-course RFA led to increased PDGFRα (4.5-fold change) and CAF subtypes B and C genes in patient 1 and subtypes A, B and D genes in patient 2. Patient 2-derived CAFs post-first RFA showed expression of PDGFRα, POSTN and MYH11 proteins. Finally, RFA led to the downregulation of classical PDAC subtype-specific genes in both patients. CONCLUSIONS: This case study suggests longitudinal EUS-FNAB as a potential resource to study tumour and microenvironmental changes associated with RFA treatment. A large sample size is required in the future to assess the efficacy and safety of the treatment and perform comprehensive statistical analysis of EUS-RFA-based molecular changes in PDAC

    Quantifying Timing Leaks and Cost Optimisation

    Full text link
    We develop a new notion of security against timing attacks where the attacker is able to simultaneously observe the execution time of a program and the probability of the values of low variables. We then show how to measure the security of a program with respect to this notion via a computable estimate of the timing leakage and use this estimate for cost optimisation.Comment: 16 pages, 2 figures, 4 tables. A shorter version is included in the proceedings of ICICS'08 - 10th International Conference on Information and Communications Security, 20-22 October, 2008 Birmingham, U
    corecore