97 research outputs found

    Calibration System with Cryogenically-Cooled Loads for CMB Polarization Detectors

    Full text link
    We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody absorbers. The primary advantage of this system is that it can generate a slightly polarized signal (∼100\sim100 mK) in the laboratory; this is at a similar level to that measured by ground-based CMB polarization experiments observing a ∼\sim 10 K sky. It is important to reproduce the observing condition in the laboratry for reliable characterization of polarimeters before deployment. In this paper, we present the design and principle of the system, and demonstrate its use with a coherent-type polarimeter used for an actual CMB polarization experiment. This technique can also be applied to incoherent-type polarimeters and it is very promising for the next-generation CMB polarization experiments.Comment: 7 pages, 9 figures Submitted to RS

    Innovative Demodulation Scheme for Coherent Detectors in CMB Experiments

    Full text link
    We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two- point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.Comment: 3 pages, 4 figure

    A systematical veto by all monitor signals in a gravitational-wave detector

    Get PDF
    We present the current state of veto studies in TAMA300 by monitor signals of the interferometer and its environment. In GW data analysis, fake GW events may bury real GW events or worse upper limits on the event rate. Thus, fake-event rejection is an important issue. In general, we can reject these fake events by the monitor signals, since these fake events are induced due to detector instabilities. However, using all monitor signals for the fake-event rejection would increase the accidental rejection probability and dead time without improving veto efficiency, since all monitor signals do not have correlations to the detector instabilities. Here, we analyze coincidences between the main and selected monitor signals with the optimal parameters for the fake-event rejection. Then, coincident events are rejected as the fake events. For the signal selection and parameter optimization, we systematically investigate the correlations with the detector instabilities. As a result, we achieved 30–99% veto efficiency using ten selected monitor signals with the 3.2% accidental rejection probability and 0.2% dead time

    Study of electron anti-neutrinos associated with gamma-ray bursts using KamLAND

    Get PDF
    We search for electron anti-neutrinos (ν‾e\overline{\nu}_e) from long and short-duration gamma-ray bursts~(GRBs) using data taken by the KamLAND detector from August 2002 to June 2013. No statistically significant excess over the background level is found. We place the tightest upper limits on ν‾e\overline{\nu}_e fluence from GRBs below 7 MeV and place first constraints on the relation between ν‾e\overline{\nu}_e luminosity and effective temperature.Comment: 16 pages and 5 figure
    • …
    corecore