967 research outputs found

    Soil Investigation and FVT Analysis in Hualien LSST SSI Research

    Get PDF
    An international joint research program, Large-Scale Seismic Test (LSST) Program at Hualien, Taiwan, is ongoing, where a large-scale model structure partly embedded in gravelly layer was constructed, in-depth site soil geotechnical investigation was performed at every one of four construction stages, that is, before excavation, after excavation before structure construction, after structure construction before backfill, and after backfill, forced vibration tests (FVTs) of the model structure before backfill (FVT-1) and after backfill (FVT-2) were performed, and seismic observation of the dynamic SSI (soil-structure interaction) system is underway. This paper describes the change of the shear wave velocity (Vs) accompanied by the construction stage progress, and predictive and correlative FVT analyses, taking above-mentioned Vs change into account

    Effects of monthly feedback of VFA measured by dual BIA method in Japanese patients with obesity: a randomized controlled study

    Get PDF
    Objective: To investigate the effects of monthly feedback of changes in visceral fat area (VFA) as measured by dual bioelectrical impedance analysis method and the importance of VFA in individuals with obesity. Methods: Thirty‐eight Japanese patients with obesity underwent VFA measurements. The feedback group was given feedback on VFA measurements each month for 4 months. The control group underwent VFA measurements at the beginning and end of the study but was not informed of the results. All the study participants completed eating behaviour and weight efficacy lifestyle questionnaires. Results: Mean age was 53.9 (14.3) years; mean body mass index was 30.6 (4.3) kg m⁻². At the 4‐month follow‐up, there was no significant difference in VFA reduction between the control and feedback groups (−4.4% vs. −3.0%; 95% CI, −3.8 to 5.5). In post‐hoc analysis using the overall group irrespective of allocation, changes of eating style were significantly associated with a reduction in VFA at 4 months (p = 0.034). Conclusions: Monthly feedback on changes in VFA does not reduce VFA. More frequent feedback may be required. In post‐hoc analysis, changes of eating style were associated with a reduction in VFA

    Ectopic cardiovascular fat in middle-aged men: effects of race/ethnicity, overall and central adiposity. The ERA JUMP study.

    Get PDF
    Background/objectivesHigher volumes of ectopic cardiovascular fat (ECF) are associated with greater risk of coronary heart disease (CHD). Identifying factors that are associated with ECF volumes may lead to new preventive efforts to reduce risk of CHD. Significant racial/ethnic differences exist for overall and central adiposity measures, which are known to be associated with ECF volumes. Whether racial/ethnic differences also exist for ECF volumes and their associations with these adiposity measures remain unclear.Subjects/methodsBody mass index (BMI), computerized tomography-measured ECF volumes (epicardial, pericardial and their summation) and visceral adipose tissue (VAT) were examined in a community-based sample of 1199 middle-aged men (24.2% Caucasians, 7.0% African-Americans, 23.6% Japanese-Americans, 22.0% Japanese, 23.2% Koreans).ResultsSignificant racial/ethnic differences existed in ECF volumes and their relationships with BMI and VAT. ECF volumes were the highest among Japanese-Americans and the lowest among African-Americans. The associations of BMI and VAT with ECF differed by racial/ethnic groups. Compared with Caucasians, for each 1-unit increase in BMI, African-Americans had lower, whereas Koreans had higher increases in ECF volumes (P-values<0.05 for both). Meanwhile, compared with Caucasians, for each 1-unit increase in log-transformed VAT, African-Americans, Japanese-Americans and Japanese had similar increases, whereas Koreans had a lower increase in ECF volumes (P-value<0.05).ConclusionsRacial/ethnic groups differed in their propensity to accumulate ECF at increasing level of overall and central adiposity. Future studies should evaluate whether reducing central adiposity or overall weight will decrease ECF volumes more in certain racial/ethnic groups. Evaluating these questions might help in designing race-specific prevention strategy of CHD risk associated with higher ECF

    Search for solar axions in XMASS, a large liquid-xenon detector

    Get PDF
    XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass \ll 1keV is gaee<5.4×1011|g_{aee}|< 5.4\times 10^{-11} (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date

    A Case of Takotsubo Cardiomyopathy after Surgery for Common Bile Duct Stones

    Get PDF
    Takotsubo cardiomyopathy (TC) is a rare reversible circulatory syndrome often detected in elderly patients after general surgery. We report the case of an 85-year-old woman who was admitted for obstructive jaundice and underwent ERCP and ENBD before operation. She finally underwent cholecystectomy and choledocholithotomy with the diagnosis of gallbladder and common bile duct stones. In the evening just after the operation, without symptoms of cardiac failure, her ECG suddenly exhibited abnormal ST-T elevation in leads II, III, and V2-V6, though neither CPK(MB) nor troponin T was elevated. Echocardiogram demonstrated basal hyperkinesis and apical dyskinesis, suggesting TC. Conservative treatment enabled recovery, ECG was normalized in a month, and the postoperative course was satisfactory. The stress on her during treatment might have been a cause of this unique cardiomyopathy, and it should be recalled that TC is a potential complication of hepato-biliary-pancreatic surgery

    Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon

    Full text link
    In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.Comment: 25 pages, 15 figure

    Angular dependence of columnar recombination in high pressure xenon gas using time profile of scintillation emission

    Get PDF
    The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~μ\mus after de-excitation emission, scintillation photons are separated to the fast and slow components. The fast component does not show dependence on the track angle relative to the drift electric field, on the other hand, the slow component increases when the track is aligned with the electric field. The result indicates that the track angle relative to the electric field can be reconstructed from the scintillation time profile.Comment: 11 pages, 11figure
    corecore