3,491 research outputs found

    Ferromagnetic Luttinger Liquids

    Full text link
    We study weak itinerant ferromagnetism in one-dimensional Fermi systems using perturbation theory and bosonization. We find that longitudinal spin fluctuations propagate ballistically with velocity v_m << v_F, where v_F is the Fermi velocity. This leads to a large anomalous dimension in the spin-channel and strong algebraic singularities in the single-particle spectral function and in the transverse structure factor for momentum transfers q ~ 2 Delta/v_F, where 2 Delta is the exchange splitting.Comment: 4 pages, 3 figure

    Enhanced Magnetoelectric Coupling in BaTiO3-BiFeO3 Multilayers—An Interface Effect

    Get PDF
    Combining various (multi-)ferroic materials into heterostructures is a promising route to enhance their inherent properties, such as the magnetoelectric coupling in BiFeO3 thin films. We have previously reported on the up-to-tenfold increase of the magnetoelectric voltage coefficient αME in BaTiO3-BiFeO3 multilayers relative to BiFeO3 single layers. Unraveling the origin and mechanism of this enhanced effect is a prerequisite to designing new materials for the application of magnetoelectric devices. By careful variations in the multilayer design we now present an evaluation of the influences of the BaTiO3-BiFeO3 thickness ratio, oxygen pressure during deposition, and double layer thickness. Our findings suggest an interface driven effect at the core of the magnetoelectric coupling effect in our multilayers superimposed on the inherent magnetoelectric coupling of BiFeO3 thin films, which leads to a giant αME coefficient of 480 Vcm−1 Oe−1 for a 16×(BaTiO3-BiFeO3) superlattice with a 4.8 nm double layer periodicity

    Novel Synthesis and High Pressure Behavior of Na0.3CoO2 x 1.3 H2O and Related Phases

    Full text link
    We have prepared powder samples of NaxCoO2 x yH2O using a new synthesis route. Superconductivity was observed in Na0.3CoO2 x 1.3H2O between 4 and 5K as indicated by the magnetic susceptibility. The bulk compressibilities of Na0.3CoO2 x 1.3H2O, Na0.3CoO2 x 0.6H2O and Na0.3CoO2 were determined using a diamond anvil cell and synchrotron powder diffraction. Chemical changes occurring under pressure when using different pressure transmitting media are discussed and further transport measurements are advocated.Comment: 7 pages, 4 figures, PRrapid submitte

    TeV Particle Astrophysics II: Summary comments

    Get PDF
    A unifying theme of this conference was the use of different approaches to understand astrophysical sources of energetic particles in the TeV range and above. In this summary I review how gamma-ray astronomy, neutrino astronomy and (to some extent) gravitational wave astronomy provide complementary avenues to understanding the origin and role of high-energy particles in energetic astrophysical sources.Comment: 6 pages, 4 figures; Conference summary talk for "TeV Particle Astrophysics II" at University of Wisconsin, Madison, 28-31 August 200

    Cold Collision Frequency Shift of the 1S-2S Transition in Hydrogen

    Get PDF
    We have observed the cold collision frequency shift of the 1S-2S transition in trapped spin-polarized atomic hydrogen. We find Δν1S−2S=−3.8(8)×10−10nHzcm3\Delta \nu_{1S-2S} = -3.8(8)\times 10^{-10} n Hz cm^3, where nn is the sample density. From this we derive the 1S-2S s-wave triplet scattering length, a1S−2S=−1.4(3)a_{1S-2S}=-1.4(3) nm, which is in fair agreement with a recent calculation. The shift provides a valuable probe of the distribution of densities in a trapped sample.Comment: Accepted for publication in PRL, 9 pages, 4 PostScript figures, ReVTeX. Updated connection of our measurement to theoretical wor

    FACT - The First G-APD Cherenkov Telescope: Status and Results

    Full text link
    The First G-APD Cherenkov telescope (FACT) is the first telescope using silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the HEGRA CT3 telescope, still located at the Observatorio del Roque de los Muchachos, and it is successfully in operation since Oct. 2011. The use of Silicon devices promises a higher photon detection efficiency, more robustness and higher precision than photo-multiplier tubes. The FACT collaboration is investigating with which precision these devices can be operated on the long-term. Currently, the telescope is successfully operated from remote and robotic operation is under development. During the past months of operation, the foreseen monitoring program of the brightest known TeV blazars has been carried out, and first physics results have been obtained including a strong flare of Mrk501. An instantaneous flare alert system is already in a testing phase. This presentation will give an overview of the project and summarize its goals, status and first results

    Whole blood microRNAs as potential biomarkers in post-operative early breast cancer patients

    Get PDF
    Background: microRNAs (miRNAs) are considered promising cancer biomarkers, showing high reliability, sensitivity and stability. Our study aimed to identify associations between whole blood miRNA profiles, presence of circulating tumor cells (CTCs) and clinical outcome in post-operative early breast cancer patients (EBC) to assess the utility of miRNAs as prognostic markers in this setting. Method: A total of 48 post-operative patients, recruited in frame of the SUCCESS A trial, were included in this retrospective study and tested with a panel of 8 miRNAs (miR-10b, −19a, − 21, − 22, −20a, − 127, − 155, −200b). Additional 17 female healthy donors with no previous history of cancer were included in the study as negative controls. Blood samples were collected at different time points (pre-adjuvant therapy, post-adjuvant therapy, 2 years follow up), total RNA was extracted and the relative concentration of each miRNA was measured by quantitative PCR and compared in patients stratified on blood collection time or CTC detection. Furthermore, we compared miRNA profiles of patients, for each time point separately, and healthy donors. CTCs were visualized and quantified with immunocytochemistry analysis. Data were analyzed using non-parametric statistical tests. Results: In our experimental system, miR-19a, miR-22 and miR-127 showed the most promising results, differentiating patients at different time points and from healthy controls, while miR-20a, miR-21 and miR-200b did not show any difference among the different groups. miR-10b and miR-155 were never detectable in our experimental system. With respect to patients’ clinical characteristics, we found a significant correlation between miR-200b and lymph node status and between miR-20a and tumor type. Furthermore, miR-127 correlated with the presence of CTCs. Finally, we found a borderline significance between Progression Free Survival and miR-19a levels. Conclusions_ This pilot study suggests that profiling whole blood miRNAs could help to better stratify post-operative EBC patients without any sign of metastasis to prevent later relapse or metastatic events

    A four-organ-chip for interconnected long-term co-culture of human intestine, liver, skin and kidney equivalents

    Get PDF
    Systemic absorption and metabolism of drugs in the small intestine, metabolism by the liver as well as excretion by the kidney are key determinants of efficacy and safety for therapeutic candidates. However, these systemic responses of applied substances lack in most in vitro assays. In this study, a microphysiological system maintaining the functionality of four organs over 28 days in co-culture has been established at a minute but standardized microsystem scale. Preformed human intestine and skin models have been integrated into the four-organ-chip on standard cell culture inserts at a size 100000-fold smaller than their human counterpart organs. A 3D-based spheroid, equivalent to ten liver lobules, mimics liver function. Finally, a barrier segregating the media flow through the organs from fluids excreted by the kidney has been generated by a polymeric membrane covered by a monolayer of human proximal tubule epithelial cells. A peristaltic on-chip micropump ensures pulsatile media flow interconnecting the four tissue culture compartments through microfluidic channels. A second microfluidic circuit ensures drainage of the fluid excreted through the kidney epithelial cell layer. This four-organ-chip system assures near to physiological fluid-to-tissue ratios. In-depth metabolic and gene analysis revealed the establishment of reproducible homeostasis among the co-cultures within two to four days, sustainable over at least 28 days independent of the individual human cell line or tissue donor background used for each organ equivalent. Lastly, 3D imaging two-photon microscopy visualised details of spatiotemporal segregation of the two microfluidic flows by proximal tubule epithelia. To our knowledge, this study is the first approach to establish a system for in vitro microfluidic ADME profiling and repeated dose systemic toxicity testing of drug candidates over 28 days.BMBF, 0315569, GO-Bio 3: Multi-Organ-Bioreaktoren für die prädiktive Substanztestung im Chipforma

    Challenges of Loss to Follow-up in Tuberculosis Research.

    Get PDF
    In studies evaluating methods for diagnosing tuberculosis (TB), follow-up to verify the presence or absence of active TB is crucial and high dropout rates may significantly affect the validity of the results. In a study assessing the diagnostic performance of the QuantiFERON®-TB Gold In-Tube test in TB suspect children in Tanzania, factors influencing patient adherence to attend follow-up examinations and reasons for not attending were examined. In 160 children who attended and 102 children who did not attend scheduled 2-month follow-up baseline health characteristics, demographic data and risk factors for not attending follow-up were determined. Qualitative interviews were used to understand patient and caretakers reasons for not returning for scheduled follow-up. Being treated for active tb in the dots program (OR: 4.14; 95% CI:1.99-8.62;p-value<0.001) and receiving money for the bus fare (OR:129; 95% CI 16->100;P-value<0.001) were positive predictors for attending follow-up at 2 months, and 21/85(25%) of children not attending scheduled follow-up had died. Interviews revealed that limited financial resources, i.e. lack of money for transportation and poor communication, were related to non-adherence. Patients lost to follow-up is a potential problem for TB research. Receiving money for transportation to the hospital and communication is crucial for adherence to follow-up conducted at a study facility. Strategies to ensure follow-up should be part of any study protocol
    • …
    corecore