107 research outputs found

    Generalized Fluid System Simulation Program, Version 6.0

    Get PDF
    The Generalized Fluid System Simulation Program (GFSSP) is a general purpose computer program for analyzing steady state and time-dependent flow rates, pressures, temperatures, and concentrations in a complex flow network. The program is capable of modeling real fluids with phase changes, compressibility, mixture thermodynamics, conjugate heat transfer between solid and fluid, fluid transients, pumps, compressors, and external body forces such as gravity and centrifugal. The thermofluid system to be analyzed is discretized into nodes, branches, and conductors. The scalar properties such as pressure, temperature, and concentrations are calculated at nodes. Mass flow rates and heat transfer rates are computed in branches and conductors. The graphical user interface allows users to build their models using the 'point, drag, and click' method; the users can also run their models and post-process the results in the same environment. Two thermodynamic property programs (GASP/WASP and GASPAK) provide required thermodynamic and thermophysical properties for 36 fluids: helium, methane, neon, nitrogen, carbon monoxide, oxygen, argon, carbon dioxide, fluorine, hydrogen, parahydrogen, water, kerosene (RP-1), isobutene, butane, deuterium, ethane, ethylene, hydrogen sulfide, krypton, propane, xenon, R-11, R-12, R-22, R-32, R-123, R-124, R-125, R-134A, R-152A, nitrogen trifluoride, ammonia, hydrogen peroxide, and air. The program also provides the options of using any incompressible fluid with constant density and viscosity or ideal gas. The users can also supply property tables for fluids that are not in the library. Twenty-four different resistance/source options are provided for modeling momentum sources or sinks in the branches. These options include pipe flow, flow through a restriction, noncircular duct, pipe flow with entrance and/or exit losses, thin sharp orifice, thick orifice, square edge reduction, square edge expansion, rotating annular duct, rotating radial duct, labyrinth seal, parallel plates, common fittings and valves, pump characteristics, pump power, valve with a given loss coefficient, Joule-Thompson device, control valve, heat exchanger core, parallel tube, and compressible orifice. The program has the provision of including additional resistance options through User Subroutines. GFSSP employs a finite volume formulation of mass, momentum, and energy conservation equations in conjunction with the thermodynamic equations of state for real fluids as well as energy conservation equations for the solid. The system of equations describing the fluid network is solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution methods. The application and verification of the code has been demonstrated through 30 example problems

    Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism.</p> <p>Case presentation</p> <p>A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed.</p> <p>Conclusion</p> <p>Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.</p

    Generalized Fluid System Simulation Program, Version 6.0

    Get PDF
    The Generalized Fluid System Simulation Program (GFSSP) is a finite-volume based general-purpose computer program for analyzing steady state and time-dependant flow rates, pressures, temperatures, and concentrations in a complex flow network. The program is capable of modeling real fluids with phase changes, compressibility, mixture thermodynamics, conjugate heat transfer between solid and fluid, fluid transients, pumps, compressors and external body forces such as gravity and centrifugal. The thermo-fluid system to be analyzed is discretized into nodes, branches, and conductors. The scalar properties such as pressure, temperature, and concentrations are calculated at nodes. Mass flow rates and heat transfer rates are computed in branches and conductors. The graphical user interface allows users to build their models using the 'point, drag, and click' method; the users can also run their models and post-process the results in the same environment. The integrated fluid library supplies thermodynamic and thermo-physical properties of 36 fluids, and 24 different resistance/source options are provided for modeling momentum sources or sinks in the branches. This Technical Memorandum illustrates the application and verification of the code through 25 demonstrated example problems

    Validating New Summary Indices for the Childhood Trauma Interview: Associations with First Onsets of Major Depressive Disorder and Anxiety Disorders

    Get PDF
    Childhood and adolescent adversity is of great interest in relation to risk for psychopathology, and interview measures of adversity are thought to be more reliable and valid than their questionnaire counterparts. One interview measure, the Childhood Trauma Interview (CTI; Fink et al., 1995), has been positively evaluated relative to similar measures, but there are some psychometric limitations to an existing scoring approach that limit the full potential of this measure. We propose several new summary indices for the CTI that permit examination of different types of adversity and different developmental periods. Our approach creates several summary indices: one sums the severity scores of adversities endorsed; another utilizes the number of minor and major (moderate to severe) adversities. The new indices were examined in association with first onsets of major depressive disorder (MDD) and anxiety disorders across a 5-year period using annual clinical diagnostic interviews (Structured Clinical Interview for DSM–IV–TR). Summary scores derived with the previously used approach were also examined for comparison. Data on 332 participants came from the Youth Emotion Project, a longitudinal study of risk for emotional disorders. Results support the predictive validity of the proposed summary scoring methods and indicate that several forms of major (but typically not minor) adversity are significantly associated with first onsets of MDD and anxiety disorders. Finally, multivariate regression models show that, in many instances, the new indices contributed significant unique variance predicting disorder onsets over and above the previously used summary indices

    Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism

    Get PDF
    PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six (81.5 %) and 78 (94.0 %) eyes were within ±0.50 D for TICL and bioptics groups, respectively. The mean Snellen UDVA was not statistically different between both procedures (p = 0.909); 53 (65.4 %) and 54 (65.1 %) eyes achieved at least 20/25 or better in TICL and bioptics groups, respectively. No eye had lost more than two lines of CDVA, and 32.1 % of eyes (26/81) in the TICL group and 57.8 % of eyes (48/83) in the bioptics group had better postoperative UDVA than preoperative CDVA (p < 0.001). Safety was not statistically different between groups (p = 0.464) while efficacy was significantly higher in the bioptics group (p = 0.000). Two eyes with a TICL were treated to correct TICL decentration. CONCLUSIONS: Bioptics showed slightly better outcomes in some clinical measures such as uncorrected visual acuity, efficacy, and refractive predictability. TICL implantation shows reliable results similar to bioptics. A single procedure with TICL implantation might be preferred, eliminating the inherent risks of laser treatments and the risks of a second surgical procedure.The authors have no proprietary interests in any of the materials mentioned in this article. This research was supported in part by a Universitat de Valencia Research Grant to Robert Montes-Mico (#SAF2009-13342 and #SAF2008-01114-E#) and Fundacao para a Ciencia e Tecnologia of Portugal through a Grant to Paulo Fernandes (#FCT-SFRH-BD-34303-2007#)

    Reliance on habits at the expense of goal-directed control following dopamine precursor depletion

    Get PDF
    Rationale Dopamine is well known to play an important role in learning and motivation. Recent animal studies have implicated dopamine in the reinforcement of stimulus-response habits, as well as in flexible, goal-directed action. However, the role of dopamine in human action control is still not well understood. Objectives We present the first investigation of the effect of reducing dopamine function in healthy volunteers on the balance between habitual and goal-directed action control. Methods The dietary intervention of acute dietary phenylalanine and tyrosine depletion (APTD) was adopted to study the effects of reduced global dopamine function on action control. Participants were randomly assigned to either the APTD or placebo group (ns = 14) to allow for a between-subjects comparison of performance on a novel three-stage experimental paradigm. In the initial learning phase, participants learned to respond to different stimuli in order to gain rewarding outcomes. Subsequently, an outcome-devaluation test and a slips-of-action test were conducted to assess whether participants were able to flexibly adjust their behaviour to changes in the desirability of the outcomes. Results APTD did not prevent stimulus-response learning, nor did we find evidence for impaired response-outcome learning in the subsequent outcome-devaluation test. However, when goal-directed and habitual systems competed for control in the slips-of-action test, APTD tipped the balance towards habitual control. These findings were restricted to female volunteers. Conclusions We provide direct evidence that the balance between goal-directed and habitual control in humans is dopamine dependent. The results are discussed in light of gender differences in dopamine function and psychopathologies

    Extension of a System Level Tool for Component Level Analysis

    No full text
    This paper presents an extension of a numerical algorithm for network flow analysis code to perform multi-dimensional flow calculation. The one dimensional momentum equation in network flow analysis code has been extended to include momentum transport due to shear stress and transverse component of velocity. Both laminar and turbulent flows are considered. Turbulence is represented by Prandtl's mixing length hypothesis. Three classical examples (Poiseuille flow, Couette flow, and shear driven flow in a rectangular cavity) are presented as benchmark for the verification of the numerical scheme
    corecore