153 research outputs found

    Effect of early supervised progressive resistance training compared to unsupervised home-based exercise after fast-track total hip replacement applied to patients with preoperative functional limitations. A single-blinded randomised controlled trial

    Get PDF
    SummaryObjectiveTo examine if 2 weekly sessions of supervised progressive resistance training (PRT) in combination with 5 weekly sessions of unsupervised home-based exercise is more effective than 7 weekly sessions of unsupervised home-based exercise in improving leg-extension power of the operated leg 10 weeks after total hip replacement (THR) in patients with lower pre-operative function.MethodA total of 73 patients scheduled for THR were randomised (1:1) to intervention group (IG, home based exercise 5 days/week and PRT 2 days/week) or control group (CG, home based exercise 7 days/week). The primary endpoint was change in leg extension power at 10 week follow up. Secondary outcomes were isometric hip muscle strength, sit-to-stand test, stair climb test, 20 m walking speed and patient-reported outcome (HOOS).ResultsSixty-two completed the trial (85%). Leg extension power increased from baseline to the 10 week follow up in both groups; mean [95% CI] IG: 0.29 [0.13; 0.45] and CG: 0.26 [0.10; 0.42] W/kg, with no between-group difference (primary outcome) (P = 0.79). Maximal walking speed (P = 0.008) and stair climb performance (P = 0.04) improved more in the IG compared to CG, no other between-group differences existed.ConclusionsIn this trial, supervised PRT twice a week in addition to 5 weekly sessions of unsupervised exercise for 10 weeks was not superior to 7 weekly sessions of unsupervised home-based exercise for 10 weeks in improving the primary outcome, leg-extension power of the operated leg, at the primary endpoint 10 weeks after surgery in THR patients with lower pre-operative function.Trial registration: NCT01214954

    Effect of local TGF-β1 and IGF-1 release on implant fixation: comparison with hydroxyapatite coating: A paired study in dogs

    Get PDF
    Background and purpose Hydroxyapatite (HA) coating stimulates the osseointegration of cementless orthopedic implants. Recently, locally released osteogenic growth factors have also been shown experimentally to stimulate osseointegration so that bone fills gaps around orthopedic implants. Here, we have compared the effect of local release of TGF-β 1 and IGF-1 with that of hydroxyapatite coating on implant fixation

    Effectiveness of accelerated perioperative care and rehabilitation intervention compared to current intervention after hip and knee arthroplasty. A before-after trial of 247 patients with a 3-month follow-up

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In Denmark, approximately 12,000 hip and knee arthroplasties were performed in 2006, and the hospital costs were close to US$ 110,000,000. In a randomized clinical trial, we have recently demonstrated the efficacy of accelerated perioperative care and rehabilitation intervention after hip and knee arthroplasty compared to current intervention under ideal circumstances. We do not, however, know whether these results could be reached under usual circumstances of healthcare practice. We therefore investigated whether length of stay after implementation of accelerated perioperative care and rehabilitation after hip and knee arthroplasty could be reduced in a normal healthcare setting, and how the achieved results matched those observed during the randomized clinical trial.</p> <p>Methods</p> <p>An effectiveness study as a before-after trial was undertaken in which all elective primary total hip and total knee arthroplasty patients were divided into a before-implementation group receiving the current perioperative procedure, and an after-implementation group receiving the new accelerated perioperative care and rehabilitation procedures as provided by a new multi-disciplinary organization. We used the Breakthrough Series Collaborative Model for implementation. The primary outcome measure was in hospital length of stay (LOS), and the secondary outcome measure was adverse effects within 3 months postoperatively.</p> <p>Results</p> <p>We included a total of 247 patients. Mean LOS was significantly (<it>P </it>< 0.001) reduced by 4.4 (95% CI 3.8–5.0) days after implementation of the accelerated intervention, from 8.8 (SD 3.0) days before implementation to 4.3 (SD 1.8) days after implementation. No significant differences in adverse effects were observed. LOS in this effectiveness study was significantly lower than LOS reported in the efficacy study.</p> <p>Conclusion</p> <p>Accelerated perioperative care and rehabilitation intervention after hip and knee arthroplasty was successfully and effectively implemented. Results obtained during usual hospital circumstances matched the results achieved under ideal circumstances in this group of patients.</p

    In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The per-operative assessment of primary stem stability may help to improve the performance of total hip replacement. Vibration analysis methods have been successfully used to assess dental implant stability, to monitor fracture healing and to measure bone mechanical properties. The objective of the present study was to evaluate in vivo a vibration analysis-based endpoint criterion for the insertion of the stem by successive surgeon-controlled hammer blows.</p> <p>Methods</p> <p>A protocol using a vibration analysis technique for the characterisation of the primary bone-prosthesis stability was tested in 83 patients receiving a custom-made, intra-operatively manufactured stem prosthesis. Two groups were studied: one (n = 30) with non cemented and one (n = 53) with partially cemented stem fixation. Frequency response functions of the stem-femur system corresponding to successive insertion stages were compared.</p> <p>Results</p> <p>The correlation coefficient between the last two frequency response function curves was above 0.99 in 86.7% of the non cemented cases. Lower values of the final correlation coefficient and deviations in the frequency response pattern were associated with instability or impending bone fracture. In the cases with a partially cemented stem an important difference in frequency response function between the final stage of non cemented trial insertion and the final cemented stage was found in 84.9% of the cases. Furthermore, the frequency response function varied with the degree of cement curing.</p> <p>Conclusion</p> <p>The frequency response function change provides reliable information regarding the stability evolution of the stem-femur system during the insertion. The protocol described in this paper can be used to accurately detect the insertion end point and to reduce the risk for intra-operative fracture.</p

    Comparison of Physical-chemical and Mechanical Properties of Chlorapatite and Hydroxyapatite Plasma Sprayed Coatings

    Get PDF
    Chlorapatite can be considered a potential biomaterial for orthopaedic applications. Its use as plasma-sprayed coating could be of interest considering its thermal properties and particularly its ability to melt without decomposition unlike hydroxyapatite. Chlorapatite (ClA) was synthesized by a high-temperature ion exchange reaction starting from commercial stoichiometric hydroxyapatites (HA). The ClA powder showed similar characteristics as the original industrial HA powder, and was obtained in the monoclinic form. The HA and ClA powders were plasma-sprayed using a low-energy plasma spraying system with identical processing parameters. The coatings were characterized by physical-chemical methods, i.e. X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and Raman spectroscopy, including distribution mapping of the main phases detected such as amorphous calcium phosphate (ACP), oxyapatite (OA), and HA or ClA. The unexpected formation of oxyapatite in ClA coatings was assigned to a side reaction with contaminating oxygenated species (O2, H2O). ClA coatings exhibited characteristics different from HA, showing a lower content of oxyapatite and amorphous phase. Although their adhesion strength was found to be lower than that of HA coatings, their application could be an interesting alternative, offering, in particular, a larger range of spraying conditions without formation of massive impurities.This study was carried out under a MNT ERA-Net Project named NANOMED. The authors gratefully thank the Midi-Pyrénées region (MNT ERA Net Midi-Pyrénées Région, NANOMED2 project) and the Institute National Polytechnique de Toulouse (BQR INPT 2011, BIOREVE project) for supporting this research work, especially the financial support for research carried out in the CIRIMAT and the LGP laboratories (France), and the Basque government and Tratamientos Superficiales Iontech, S.A. for their financial and technical support under the IG-2007/0000381 grant for the development of the LEPS device and deposition of the coatings carried out in Inasmet-Tecnalia. The French industrial collaborators (TEKNIMED SA and 2PS SA) were financed by the OSEO programs

    Analysis of polyethylene wear in plain radiographs: The number of radiographs influences the results

    Get PDF
    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs
    • …
    corecore