667 research outputs found

    Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector

    Full text link
    ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam line directly upstream of the MINOS Near Detector from September 2009 to February 2010, during which thousands of neutrino and antineutrino events were collected. The MINOS Near Detector was used to measure muons downstream of ArgoNeuT. Though ArgoNeuT is primarily an R&D project, the data collected provide a unique opportunity to measure neutrino cross sections in the 0.1-10 GeV energy range. Fully reconstructing the muon from these interactions is imperative for these measurements. This paper focuses on the complete kinematic reconstruction of neutrino-induced through-going muons tracks. Analysis of this high statistics sample of minimum ionizing tracks demonstrates the reliability of the geometric and calorimetric reconstruction in the ArgoNeuT detector

    Prevalence of Oral Pain and Barriers to use of Emergency Oral Care Facilities Among Adult Tanzanians.

    Get PDF
    Oral pain has been the major cause of the attendances in the dental clinics in Tanzania. Some patients postpone seeing the dentist for as long as two to five days. This study determines the prevalence of oral pain and barriers to use of emergency oral care in Tanzania. Questionnaire data were collected from 1,759 adult respondents aged 18 years and above. The study area covered six urban and eight rural study clusters, which had been selected using the WHO Pathfinder methodology. Chi-square tests and logistic regression analyses were performed to identify associations.\ud Forty two percent of the respondents had utilized the oral health care facilities sometimes in their lifetime. About 59% of the respondents revealed that they had suffered from oral pain and/or discomfort within the twelve months that preceded the study, but only 26.5% of these had sought treatment from oral health care facilities. The reasons for not seeking emergency care were: lack of money to pay for treatment (27.9%); self medication (17.6%); respondents thinking that pain would disappear with time (15.7%); and lack of money to pay for transport to the dental clinic (15.0%). Older adults were more likely to report that they had experienced oral pain during the last 12 months than the younger adults (OR = 1.57, CI 1.07-1.57, P < 0.001). Respondents from rural areas were more likely report dental clinics far from home (OR = 5.31, CI = 2.09-13.54, P < 0.001); self medication at home (OR = 3.65, CI = 2.25-5.94, P < 0.001); and being treated by traditional healer (OR = 5.31, CI = 2.25-12.49, P < 0.001) as reasons for not seeking emergency care from the oral health care facilities than their counterparts from urban areas. Oral pain and discomfort were prevalent among adult Tanzanians. Only a quarter of those who experienced oral pain or discomfort sought emergency oral care from oral health care facilities. Self medication was used as an alternative to using oral care facilities mainly by rural residents. Establishing oral care facilities in rural areas is recommended

    The ArgoNeuT Detector in the NuMI Low-Energy beam line at Fermilab

    Get PDF
    The ArgoNeuT liquid argon time projection chamber has collected thousands of neutrino and antineutrino events during an extended run period in the NuMI beam-line at Fermilab. This paper focuses on the main aspects of the detector layout and related technical features, including the cryogenic equipment, time projection chamber, read-out electronics, and off-line data treatment. The detector commissioning phase, physics run, and first neutrino event displays are also reported. The characterization of the main working parameters of the detector during data-taking, the ionization electron drift velocity and lifetime in liquid argon, as obtained from through-going muon data complete the present report.Comment: 43 pages, 27 figures, 5 tables - update referenc

    Redox proteomics of the inflammatory secretome identifies a common set of redoxins and other glutathionylated proteins released in inflammation, influenza virus infection and oxidative stress

    Get PDF
    Protein cysteines can form transient disulfides with glutathione (GSH), resulting in the production of glutathionylated proteins, and this process is regarded as a mechanism by which the redox state of the cell can regulate protein function. Most studies on redox regulation of immunity have focused on intracellular proteins. In this study we have used redox proteomics to identify those proteins released in glutathionylated form by macrophages stimulated with lipopolysaccharide (LPS) after pre-loading the cells with biotinylated GSH. Of the several proteins identified in the redox secretome, we have selected a number for validation. Proteomic analysis indicated that LPS stimulated the release of peroxiredoxin (PRDX) 1, PRDX2, vimentin (VIM), profilin1 (PFN1) and thioredoxin 1 (TXN1). For PRDX1 and TXN1, we were able to confirm that the released protein is glutathionylated. PRDX1, PRDX2 and TXN1 were also released by the human pulmonary epithelial cell line, A549, infected with influenza virus. The release of the proteins identified was inhibited by the anti-inflammatory glucocorticoid, dexamethasone (DEX), which also inhibited tumor necrosis factor (TNF)-α release, and by thiol antioxidants (N-butanoyl GSH derivative, GSH-C4, and N-acetylcysteine (NAC), which did not affect TNF-α production. The proteins identified could be useful as biomarkers of oxidative stress associated with inflammation, and further studies will be required to investigate if the extracellular forms of these proteins has immunoregulatory functions
    • …
    corecore